Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-01-29 Cont ID  
Sent By rmcdouga Date 2013-01-29 Time 09:55 Rev Time 0.00
Received By rmcdouga Date 2013-01-29 Time 09:55 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-12-06 Cont ID  
Sent By rmcdouga Date 2012-12-06 Time 11:41 Rev Time 0.00
Received By rmcdouga Date 2012-12-06 Time 11:41 Sent To  
Notes
2012-12-06 13:32:122010 FBC
  
 DENIED BY BUILDING
  
 1) SHOW COMPLIANCE WITH 2010 FBC ENERGY CONSERVATION
 SECTION 402 .1 (PRESCRIPTIVE) OR 405 (PERFORMANCE) AS
 REQUIRED BY SECTION 101.4.5.
  
 2) SUBMIT TWO SETS OF PRODUCT APPROVALS FOR THE NEW
 ROOF COVERING THAT WILL BE INSTALLED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2013-01-10 Cont ID  
Sent By rlecky Date 2013-01-10 Time 14:22 Rev Time 0.00
Received By rlecky Date 2013-01-10 Time 14:22 Sent To  
Notes
2013-01-10 14:23:50ELECTRICAL REVISED - SEE 8.5 X 11 SHEETS.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2012-11-27 Cont ID  
Sent By rlecky Date 2012-11-27 Time 15:26 Rev Time 0.00
Received By rlecky Date 2012-11-27 Time 14:29 Sent To  
Notes
2012-11-27 15:27:1712110598
 726 NEW YORK ST.
 RESIDENTIAL REMODEL
  
 PLEASE REVISE THE PLANS IN RESPONSE TO THE FOLLOWING
 ELECTRICAL REVIEW COMMENTS.
  
 PROVIDE A REVISED ELECTRIC SERVICE RISER PLAN WITH
 PANELS, MAIN BREAKERS, MAIN DISCONNECTS, WIRE SIZES,
 GROUNDING ETC. SHOW LOCATION OF ALL PANEL BOARDS. NEC
 215.15
  
 REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO
 INCLUDE INTERCONNECTED SMOKE ALARMS BOTH WITHIN AND
 OUTSIDE EACH SLEEPING AREA. IF THE RESIDENCE HAS GAS
 APPLIANCES, AN ATTACHED GARAGE OR A FIRE PLACE A CARBON
 MONOXIDE DETECTOR IS REQUIRED WITHIN TEN FEET OF EACH
 ROOM USED FOR SLEEPING. 2010 FBC R314, 315
  
 AN INTERSYSTEM BONDING STRIP IS REQUIRED AT THE MAIN
 SERVICE GROUND. NEC 250.94
  
 A GFCI PROTECTED RECEPTACLE IS REQUIRED OUTSIDE AT THE
 BACK ENTRANCE AREA. NEC 210.52
 (E)
  
 THE NEW BATHROOM REQUIRES A DEDICATED 20 AMP BRANCH
 CIRCUIT. NEC 210.11 (C) (3)
  
 ROBERT LECKY
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6718
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2012-12-06 Cont ID  
Sent By rmcdouga Date 2012-12-06 Time 11:20 Rev Time 0.00
Received By rmcdouga Date 2012-12-06 Time 11:20 Sent To  
Notes
2012-12-06 11:25:43NO GAS PERMIT APPLICATION OR GAS RISER DIAGRAM WAS
 SUBMITTED. SEPARATE APPLICATION, PERMIT AND REVIEW IS
 REQUIRED.

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2012-11-21 Cont ID  
Sent By fmittner Date 2012-11-21 Time 15:26 Rev Time 0.00
Received By fmittner Date 2012-11-21 Time 15:26 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-01-29 Cont ID  
Sent By rmcdouga Date 2013-01-29 Time 10:57 Rev Time 0.00
Received By rmcdouga Date 2013-01-23 Time 14:48 Sent To  
Notes
2013-01-28 14:48:51SENT TO MCDOUGAL'S DESK FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-12-06 Cont ID  
Sent By rmcdouga Date 2012-12-06 Time 13:32 Rev Time 0.00
Received By rmcdouga Date 2012-11-21 Time 10:11 Sent To  
Notes
2012-11-26 10:12:43SENT TO R2 SHELF FOR REVIEW. JG.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2013-01-29 Cont ID  
Sent By rmcdouga Date 2013-01-29 Time 09:55 Rev Time 0.00
Received By rmcdouga Date 2013-01-29 Time 09:55 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2012-12-06 Cont ID  
Sent By rmcdouga Date 2012-12-06 Time 10:33 Rev Time 0.00
Received By rmcdouga Date 2012-12-06 Time 10:33 Sent To  
Notes
2012-12-06 11:07:15ENCLOSED PORCH IS BEING CONVERTED TO CONDITIONED LIVING
 SPACE. AN IMPACT FEE REVIEW BY PALM BEACH COUNTY IS
 REQUIRED.

Review Stop P PLUMBING
Rev No 2 Status P Date 2013-01-29 Cont ID  
Sent By rmcdouga Date 2013-01-29 Time 10:57 Rev Time 0.00
Received By rmcdouga Date 2013-01-29 Time 10:57 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2012-12-06 Cont ID  
Sent By rmcdouga Date 2012-12-06 Time 11:26 Rev Time 0.00
Received By rmcdouga Date 2012-12-06 Time 11:26 Sent To  
Notes
2012-12-06 11:40:442010 FBC
  
 1) TWO SETS OF PLUMBING RISER DRAWINGS WERE SUBMITTED.
 THE SIGNED AND SEALED PLANS DO NOT SPECIFY THE WASHER
 OR KITCHEN SINK. THE ONES FROM DON LIPSCOMB ARE CODE
 COMPLIANT. ONLY ONE OF THE DRAWINGS CAN BE APPROVED FOR
 PERMIT. THE SEALED PLUMBING RISER CAN BE CORRECTED OR
 REMOVED FROM THE PLANS. PLEASE CLARIFY. CITY AMENDMENTS
 107.2.1
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2012-11-21 Cont ID  
Sent By fmittner Date 2012-11-21 Time 15:27 Rev Time 0.00
Received By fmittner Date 2012-11-21 Time 15:27 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved