Plan Review Details - Permit 12100609
Plan Review Stops For Permit 12100609 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2012-10-19 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-10-19 |
Time |
09:58 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-10-19 |
Time |
09:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2012-11-06 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2012-11-06 |
Time |
09:33 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2012-11-06 |
Time |
09:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2012-10-31 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2012-10-31 |
Time |
10:16 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2012-10-31 |
Time |
10:06 |
Sent To |
|
|
Notes |
2012-10-31 10:16:39 | 12100609 | | 5200 N. FLAGLER DRIVE # 1103 | | APARTMENT REMODEL | | | | SCOPE OF ELECTRICAL WORK INSUFFICIENTLY DETAILED. | | PLEASE PROVIDE THE FOLLOWING: | | | | INDICATE THE SIZE AND LOCATION OF THE ELECTRICAL PANEL. | | ON A FLOOR PLAN SHOW THE LOCATION OF ALL NEW AND | | EXISTING LIGHTING OUTLETS, RECEPTACLE OUTLETS AND SMOKE | | DETECTORS. NEC 215.5 | | VERIFY SMOKE ALARMS ARE PROVIDED INSIDE AND OUTSIDE ALL | | SLEEPING AREAS. 2010 FBC R314, 315 | | VERIFY THE KITCHEN COUNTER TOP RECEPTACLES AND BATHROOM | | RECEPTACLES ARE GFCI PROTECTED. NEC 210.8 | | INDICATE THAT ALL NEW RECEPTACLES WILL BE TAMPER | | RESISTANT. NEC 406.11 | | ALL NEW GENERAL PURPOSE BRANCH CIRCUITS MUST BE | | PROTECTED WITH ARC FAULT CIRCUIT INTERRUPTERS. NEC | | 210.12 | | | | ROBERT LECKY | | COMMERCIAL COMBINATION PLANS EXAMINER | | [email protected] | | 561-805-6718 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2012-11-06 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2012-11-06 |
Time |
09:33 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2012-11-05 |
Time |
15:09 |
Sent To |
|
|
Notes |
2012-11-05 15:10:11 | UNDER 5 K ELECTRIC |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2012-10-31 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2012-10-31 |
Time |
10:16 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2012-10-18 |
Time |
09:58 |
Sent To |
|
|
Notes |
2012-10-19 10:00:10 | SENT TO ELECTRICAL BOX. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2012-10-19 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-10-19 |
Time |
09:56 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-10-19 |
Time |
09:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2012-10-19 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-10-19 |
Time |
09:55 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-10-19 |
Time |
09:55 |
Sent To |
|
|
Notes |
|
|
|