Plan Review Details - Permit 12100609
Plan Review Stops For Permit 12100609
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2012-10-19 Cont ID  
Sent By rmcdouga Date 2012-10-19 Time 09:58 Rev Time 0.00
Received By rmcdouga Date 2012-10-19 Time 09:58 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2012-11-06 Cont ID  
Sent By rlecky Date 2012-11-06 Time 09:33 Rev Time 0.00
Received By rlecky Date 2012-11-06 Time 09:22 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2012-10-31 Cont ID  
Sent By rlecky Date 2012-10-31 Time 10:16 Rev Time 0.00
Received By rlecky Date 2012-10-31 Time 10:06 Sent To  
Notes
2012-10-31 10:16:3912100609
 5200 N. FLAGLER DRIVE # 1103
 APARTMENT REMODEL
  
 SCOPE OF ELECTRICAL WORK INSUFFICIENTLY DETAILED.
 PLEASE PROVIDE THE FOLLOWING:
  
 INDICATE THE SIZE AND LOCATION OF THE ELECTRICAL PANEL.
 ON A FLOOR PLAN SHOW THE LOCATION OF ALL NEW AND
 EXISTING LIGHTING OUTLETS, RECEPTACLE OUTLETS AND SMOKE
 DETECTORS. NEC 215.5
 VERIFY SMOKE ALARMS ARE PROVIDED INSIDE AND OUTSIDE ALL
 SLEEPING AREAS. 2010 FBC R314, 315
 VERIFY THE KITCHEN COUNTER TOP RECEPTACLES AND BATHROOM
 RECEPTACLES ARE GFCI PROTECTED. NEC 210.8
 INDICATE THAT ALL NEW RECEPTACLES WILL BE TAMPER
 RESISTANT. NEC 406.11
 ALL NEW GENERAL PURPOSE BRANCH CIRCUITS MUST BE
 PROTECTED WITH ARC FAULT CIRCUIT INTERRUPTERS. NEC
 210.12
  
 ROBERT LECKY
 COMMERCIAL COMBINATION PLANS EXAMINER
 [email protected]
 561-805-6718
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-11-06 Cont ID  
Sent By rlecky Date 2012-11-06 Time 09:33 Rev Time 0.00
Received By rlecky Date 2012-11-05 Time 15:09 Sent To  
Notes
2012-11-05 15:10:11UNDER 5 K ELECTRIC

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-10-31 Cont ID  
Sent By rlecky Date 2012-10-31 Time 10:16 Rev Time 0.00
Received By rlecky Date 2012-10-18 Time 09:58 Sent To  
Notes
2012-10-19 10:00:10SENT TO ELECTRICAL BOX.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2012-10-19 Cont ID  
Sent By rmcdouga Date 2012-10-19 Time 09:56 Rev Time 0.00
Received By rmcdouga Date 2012-10-19 Time 09:56 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2012-10-19 Cont ID  
Sent By rmcdouga Date 2012-10-19 Time 09:55 Rev Time 0.00
Received By rmcdouga Date 2012-10-19 Time 09:55 Sent To  
Notes
***NONE***