Plan Review Details - Permit 12100571
Plan Review Stops For Permit 12100571
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2013-02-21 Cont ID  
Sent By jgomez Date 2013-02-21 Time 11:19 Rev Time 0.00
Received By jgomez Date 2013-02-21 Time 11:18 Sent To  
Notes
2013-02-21 11:25:35BUILDING REVIEW APPROVED WITH PROVISO:
 1- NEED TO PROVIDE HEATING AS REQUIRED BY SEC. R303.8
 OF 2010 FBC-RESIDENTIAL. PROVIDE COMPLETE INFORMATION
 UNDER A SEPARATE PERMIT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2013-01-29 Cont ID  
Sent By jgomez Date 2013-01-29 Time 11:32 Rev Time 0.00
Received By jgomez Date 2013-01-29 Time 11:32 Sent To  
Notes
2013-01-29 14:06:31BUILDING REVIEW APPROVED WITH PROVISO:
 1- NEED TO PROVIDE HEATING AS REQUIRED BY SEC. R303.8
 OF 2010 FBC-RESIDENTIAL. PROVIDE COMPLETE INFORMATION
 UNDER A SEPARATE PERMIT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-11-20 Cont ID  
Sent By jgomez Date 2012-11-20 Time 15:38 Rev Time 0.00
Received By jgomez Date 2012-11-20 Time 15:04 Sent To  
Notes
2012-11-20 15:45:56RESIDENTIAL (R3) GARAGE CONVERSION/ALTERATION BUILDING
 REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- BRING PLANS TO PALM BEACH COUNTY BUILDING (2300 N.
 JOG RD.) TO VERIFY IF IMPACT FEES ARE DUE. BRING BACK
 COUNTY STAMPED PLANS AND COPY OF PAID RECEIPT IF FEES
 ARE DUE. REQ'D BY COUNTY IMPACT FEE ORDINANCE OF THE
 UNIFIED LAND DEVELOPMENT CODE.
  
 2- THIS IS NOT AN ALTERATION LEVEL 2. THIS IS A CHANGE
 OF OCCUPANCY AND ALTERATION LEVEL 3. SEE SEC. 406 AND
 SEC. 912.1.1 OF 2010 FBC-EXISTING BUILDING. REVISE
 INFORMATION ON COVER SHEET.
  
 3- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) FRENCH DOORS AS SHOWN ON PLANS. NOA 11-1013.22
 SUBMITTED EXPIRED ON OCTOBER 18, 2012. NEED TO PROVIDE
 CURRENT NOA.
  
 B) SINGLE HUNG WINDOWS AS SPECIFIED ON PLANS.
  
 C) PRECAST LINTELS AS SPECIFIED ON PLANS.
  
 D) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON
 PLANS. PROVIDE ONLY THE COVER PAGE AND PAGE SHOWING THE
 SPECIFIED CONNECTOR.
  
 4- ENGINEER OF RECORD TO REVIEW AND APPROVE ALL PRODUCT
 APPROVALS AS REQUIRED BY SEC. 107.3.4.1 OF CITY
 AMENDMENTS TO FBC.
 ***NOTE: PERSON WHO SIGNED PRODUCT APPROVALS SUBMITTED
 IS NOT THE ENGINEER OF RECORD. NEED THE SIGNATURE OF
 THE ENGINEER OF RECORD.
  
 5- ENGINEER OF RECORD TO UPDATE THE FIRM'S "FOREST HILL
 ENGINEERING, INC." STATUS. ACCORDING TO THE FLORIDA
 DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION
 (DBPR) WEBSITE THE STATUS OF THIS FIRM IS NOT CURRENT.
 ENGINEER TO CONTACT DBPR AND UPDATE ENGINEERING FIRM'S
 STATUS AS REQUIRED. BY SEC. 61G15-23.002 OF FLORIDA
 ADMINISTRATIVE CODE AND CHAPTER 471 FLORIDA STATUTE.
  
 6- ENGINEER OF RECORD TO SIGN AND SEAL ALL SHEETS. THE
 FIRST THREE PAGES WERE NOT SIGNED AND SEALED AS
 REQUIRED BY SEC. 61G15-23.002 FLORIDA ADMINISTRATIVE
 CODE AND CHAPTER 471 FLORIDA STATUTE.
  
 7- SHEET 3.0:
 A) WINDOW #4 SHOWN ON THE WINDOW SCHEDULE DOESN'T MATCH
 WINDOW SHOWN ON FLOOR PLAN AND EXTERIOR ELEVATIONS.
 REVISE AS REQUIRED TO MATCH. SEC. 107.2.1 CITY
 AMENDMENTS TO FBC.
  
 B) WINDOWS #3 AND #4 SHOWN ON THE WINDOW SCHEDULE ARE
 LOCATED ON ZONE 5 NOT 4. REVISE AS REQUIRED. ZONE 5 IS
 A LEAST 4'-0" SEE NOTE A ON FIGURE R301.2(7) OF 2010
 FBC-RESIDENTIAL.
  
 C) PROVIDE STRUCTURAL BUCK DETAIL USING 2X BUCK AS
 SPECIFIED ON WINDOW SCHEDULE NOTE. SPECIFY ALL
 FASTENERS. SEC. 107.2.1 CITY AMENDMENTS.
  
 D) WHERE IS WINDOW #5 SHOWN ON THE WINDOW SCHEDULE.
 PLANS AND ELEVATIONS DON'T SHOW THIS WINDOW. AND,
 CLARIFY WHAT KIND OF WINDOW IS "(2)SH-32 PICTURE" AS
 SPECIFIED ON WINDOW #5. SEC. 107.2.1 CITY AMENDMENTS.
  
 8- WIND LOAD SCHEDULE ON SHEET 7.0:
 A) CLARIFY WHY THE VALUES INDICATED ON THE ROOF WIND
 AREAS ARE THE SAME FOR ALL THREE ROOF ZONES. SEE TABLE
 R301.2(2) OF 2010 FBC-RESIDENTIAL.
  
 B) CORNER DISTANCE "A" SHALL BE 4'-0" MIN. NOT 3'-0".
 SEE FIGURE R301.2(7) AND REVISE AS REQUIRED.
  
 C) CLARIFY WHY USING 50 S.F. AS THE AREA OF COMPONENT.
 SEE NOTE A ON THE TABLE R301.2(2) AND REVISE AS
 REQUIRED.
  
 9-SPECIFY HOW PROVIDING THE REQUIRED HEATING BY SEC.
 R303.8 OF 2010 FBC-RESIDENTIAL.
 ***NOTE: THERE ARE NO PLANS SUBMITTED SHOWING ANY A/C
 WORK. ELECTRICAL PLAN SHOWS A/C UNIT BUT THERE ARE NO
 PLANS. MECHANICAL PERMIT REQUIRED ALSO.
  
 10- SPECIFY HOW PROTECTING ALL THE WOOD THAT IS SHOWN
 ON PLANS AND DETAILS WHEN IN CONTACT WITH CONCRETE OR
 CONCRETE BLOCK. SEC. R317.1 OF 2010 FBC-RESIDENTIAL.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2013-02-22 Cont ID  
Sent By rlecky Date 2013-02-22 Time 08:21 Rev Time 0.00
Received By rlecky Date 2013-02-22 Time 08:15 Sent To  
Notes
2013-02-14 13:39:50NEW PLANS SUBMITTED. JG.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2012-11-09 Cont ID  
Sent By rlecky Date 2012-11-09 Time 14:09 Rev Time 0.00
Received By rlecky Date 2012-11-09 Time 12:47 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 3 Status P Date 2013-02-26 Cont ID  
Sent By fmittner Date 2013-02-26 Time 12:39 Rev Time 0.00
Received By fmittner Date 2013-02-26 Time 12:39 Sent To  
Notes
2013-02-14 13:38:55NEW PLANS SUBMITTED. JG.

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2012-11-19 Cont ID  
Sent By fmittner Date 2012-11-19 Time 11:44 Rev Time 0.00
Received By fmittner Date 2012-11-19 Time 11:44 Sent To  
Notes
2012-11-19 11:45:23WINDOWS ARE EXISITNG. ONLY GARAGE DOORS TO BE REPLACED.

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2012-10-18 Cont ID  
Sent By fmittner Date 2012-10-18 Time 14:29 Rev Time 0.00
Received By fmittner Date 2012-10-18 Time 14:29 Sent To  
Notes
2012-10-18 14:30:30ALTERATIONS REQUIRE SUBMITTAL OF A COA (CERTIFICATE OF
 APPROPRIATENESS) APPLICATION. PLEASE CONTACT FRIEDERIKE
 MITTNER, CITY HISTORIC PRESERVATION PLANNER AT
 822-1457.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2013-02-28 Cont ID  
Sent By jgomez Date 2013-02-28 Time 09:05 Rev Time 0.00
Received By jgomez Date 2013-02-13 Time 13:35 Sent To  
Notes
2013-02-14 13:36:56NEW PLANS SUBMITTED. SENT TO R13 SHELF FOR
 REVIEW/PROCESSING. JG.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2013-01-29 Cont ID  
Sent By jgomez Date 2013-01-29 Time 15:51 Rev Time 0.00
Received By jgomez Date 2013-01-23 Time 09:33 Sent To  
Notes
2013-01-28 09:34:13SENT TO JULIO'S DESK FOR REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-11-20 Cont ID  
Sent By jgomez Date 2012-11-20 Time 17:10 Rev Time 0.00
Received By jgomez Date 2012-10-18 Time 10:28 Sent To  
Notes
2012-10-19 10:30:01R12

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2013-02-21 Cont ID  
Sent By jgomez Date 2013-02-21 Time 11:25 Rev Time 0.00
Received By jgomez Date 2013-02-21 Time 11:25 Sent To  
Notes
2013-02-21 11:27:13MU-2012-022225. JG.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2013-01-29 Cont ID  
Sent By jgomez Date 2013-01-29 Time 15:52 Rev Time 0.00
Received By jgomez Date 2013-01-29 Time 15:52 Sent To  
Notes
2013-01-29 15:53:17BRING PLANS TO PALM BEACH COUNTY BUILDING (2300 N. JOG
 RD.) TO VERIFY IF IMPACT FEES ARE DUE. BRING BACK
 STAMPED PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE.
 JG.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2012-11-20 Cont ID  
Sent By jgomez Date 2012-11-20 Time 15:36 Rev Time 0.00
Received By jgomez Date 2012-11-20 Time 15:36 Sent To  
Notes
2012-11-20 15:37:54BRING PLANS TO PALM BEACH COUNTY BUILDING (2300 N. JOG
 RD.) TO VERIFY IF IMPACT FEES ARE DUE. BRING BACK
 STAMPED PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE.
 JG.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status   Date 2013-10-17 Cont ID  
Sent By hmoser Date 2013-10-17 Time 08:45 Rev Time 0.00
Received By hmoser Date 2013-10-17 Time 08:45 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2012-11-20 Cont ID  
Sent By jgomez Date 2012-11-20 Time 17:09 Rev Time 0.00
Received By jgomez Date 2012-11-20 Time 17:09 Sent To  
Notes
2012-11-20 17:10:12NO INFORMATION SUBMITTED. PROVIDE COMPLETE A/C
 INFORMATION UNDER A SEPARATE PERMIT. JG

Review Stop P PLUMBING
Rev No 2 Status P Date 2013-02-21 Cont ID  
Sent By jgomez Date 2013-02-21 Time 14:10 Rev Time 0.00
Received By jgomez Date 2013-02-21 Time 14:10 Sent To  
Notes
2013-02-14 13:40:31NEW PLANS SUBMITTED. JG.

Review Stop P PLUMBING
Rev No 1 Status P Date 2012-11-19 Cont ID  
Sent By lwagner Date 2012-11-19 Time 11:17 Rev Time 0.00
Received By lwagner Date 2012-11-19 Time 11:03 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2013-02-26 Cont ID  
Sent By fmittner Date 2013-02-26 Time 12:40 Rev Time 0.00
Received By fmittner Date 2013-02-26 Time 12:39 Sent To  
Notes
2013-02-26 12:40:29NOT PERMITTED AS SECONDARY UNIT. NO COOKING FACILITIES.
2013-02-14 13:41:03NEW PLANS SUBMITTED. JG.

Review Stop Z ZONING
Rev No 2 Status P Date 2012-11-19 Cont ID  
Sent By fmittner Date 2012-11-19 Time 11:44 Rev Time 0.00
Received By fmittner Date 2012-11-19 Time 11:44 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2012-10-18 Cont ID  
Sent By fmittner Date 2012-10-18 Time 14:30 Rev Time 0.00
Received By fmittner Date 2012-10-18 Time 14:30 Sent To  
Notes
2012-10-18 14:34:51PUT IN INCOMING RESIDENTIAL BOX
2012-10-18 14:34:18LOT WIDTH OF 50' DOES NOT PERMIT SECONDARY UNIT ON
 SITE.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved