Plan Review Details - Permit 12100548
Plan Review Stops For Permit 12100548
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2012-10-31 Cont ID  
Sent By rmcdouga Date 2012-10-31 Time 09:52 Rev Time 0.00
Received By rmcdouga Date 2012-10-31 Time 09:52 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2012-10-31 Cont ID  
Sent By rmcdouga Date 2012-10-31 Time 09:52 Rev Time 0.00
Received By rmcdouga Date 2012-10-31 Time 09:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-10-31 Cont ID  
Sent By rmcdouga Date 2012-10-31 Time 10:12 Rev Time 0.00
Received By rmcdouga Date 2012-10-18 Time 07:07 Sent To  
Notes
2012-10-18 07:07:19TO ZONING
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2012-11-01 Cont ID  
Sent By rmcdouga Date 2012-11-01 Time 07:19 Rev Time 0.00
Received By rmcdouga Date 2012-11-01 Time 07:19 Sent To  
Notes
2012-11-01 07:19:38REDLINED PLANS PER CONTRACTOR.

Review Stop P PLUMBING
Rev No 1 Status F Date 2012-10-31 Cont ID  
Sent By rmcdouga Date 2012-10-31 Time 10:12 Rev Time 0.00
Received By rmcdouga Date 2012-10-31 Time 10:12 Sent To  
Notes
2012-10-31 10:12:532010 FBC
  
 DENIED BY PLUMBING
  
 1) THE MAXIMUM FLOW RATE OF THE VARIABLE SPEED PUMP IS
 REQUIRED TO BE USED TO DETERMINE THE WATER VELOCITY IN
 THE PIPES. THE PENTAIR INTELLIFLO VS 3050 HAS A FLOW
 RATE OF 145 GPM WITH 50' TDH AT THE MAXIMUM OF 3450
 RPM. THIS MEANS THAT THE VELOCITY OF THE WATER IN THE
 2-1/2" PIPING WILL BE 9.48 FEET PER SECOND. THIS
 EXCEEDS THE MAXIMUM WATER VELOCITY OF 8 FEET PER SECOND
 IN SUCTION PIPING ALLOWED BY FBC R4101.6. THERE IS NO
 BRANCH PIPING BECAUSE A CHANNEL DRAIN IS SPECIFIED
 RATHER THAN TWO MAIN DRAINS. THE WATER VELOCITY IN THE
 2" PRESSURE PIPING WILL BE 14.81 FEET PER SECOND WHICH
 EXCEEDS THE MAXIMUM WATER VELOCITY OF 10 FEET PER
 SECOND ALLOWED BY FBC R4101.6 IN PRESSURE PIPING.
 PLEASE CORRECT.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2012-10-24 Cont ID  
Sent By mdekle Date 2012-10-24 Time   Rev Time  
Received By mdekle Date 2012-10-18 Time   Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved