Plan Review Details - Permit 12100509
Plan Review Stops For Permit 12100509
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2012-10-22 Cont ID  
Sent By jgomez Date 2012-10-22 Time 11:00 Rev Time 0.00
Received By jgomez Date 2012-10-22 Time 11:00 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-10-17 Cont ID  
Sent By jgomez Date 2012-10-17 Time 12:49 Rev Time 0.00
Received By jgomez Date 2012-10-17 Time 11:33 Sent To  
Notes
2012-10-17 13:47:21RESIDENTIAL (R3) REROOF BUILDING REVIEW COMMENTS.
 CODE: 2010 FBC-RESIDENTIAL.
  
 1- SHINGLES ON A 3/12 PITCH REQUIRES 2 LAYERS OF
 UNDERLAYMENT. SEC. R905.2.2. IF CONTRACTOR IS PROPOSING
 TO USE SELF-ADHERING UNDERLAYMENT APPLIED DIRECT TO THE
 DECK, THEN, REQUEST FOR APPROVAL FOR THIS METHOD NEEDS
 TO BE SUBMITTED FOR THE BUILDING OFFICIAL APPROVAL
 UNDER ALTERNATIVE MATERIALS, DESIGN AND METHODS OF
 CONSTRUCTION SEC. 104.11 CITY AMENDMENTS TO FBC.
  
 2- FLAT ROOF NOA SUBMITTED: CLEARLY IDENTIFY WHICH
 APPROVED ASSEMBLY IS GOING TO BE INSTALLED. SEC.
 107.2.1.2 CITY AMENDMENTS TO FBC.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-10-22 Cont ID  
Sent By jgomez Date 2012-10-22 Time 11:00 Rev Time 0.00
Received By jgomez Date 2012-10-22 Time 11:00 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-10-17 Cont ID  
Sent By jgomez Date 2012-10-17 Time 11:37 Rev Time 0.00
Received By jgomez Date 2012-10-17 Time 11:37 Sent To  
Notes
***NONE***