Plan Review Stops For Permit 12100355 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2013-01-08 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2013-01-08 |
Time |
15:29 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2013-01-08 |
Time |
15:29 |
Sent To |
|
|
Notes |
2013-01-08 15:32:44 | I SPOKE WITH THE ARCHITECT OF RECORD MARK MCCREE HE | | WOULD LIKE TO DELETE THE REPLACEMENT OF JALOUSIE | | WINDOWS FROM THE SCOPE OF WORK, E-MAIL SENT FOR | | DOCUMENTATION. | | SEE ATTACHMENT. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | CONSTRUCTION SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2013-01-08 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2013-01-08 |
Time |
15:29 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2013-01-08 |
Time |
09:54 |
Sent To |
|
|
Notes |
2013-01-08 09:56:40 | BUILDING PLAN REVIEW | | PERMIT: 12100355 | | ADD: 825 SOUTHERN BLVD SUITE # 5 | | CONT: MTC REMODELING | | TEL: (561)655-5956 | | | | 2010 FLORIDA BUILDING CODE W | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 4TH REVIEW | | JAN. 08/2013 | | ACTION: DENIED | | | | 1) COMPLIED. | | | | 2) 4TH REQUEST. 2010 FBC 107.3.4.1 PRODUCT APPROVALS. | | THOSE PRODUCTS WHICH ARE REGULATED BY THE DCA RULE | | 9N-03 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | JURISDICTIONAL APPROVAL. | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | SHOP DRAWINGS ETC.. | | | | 3) 4TH REQUEST. 2010 FBC-B 1609.1.1 DETERMINATION OF | | WIND DESIGN- CHAPTER 6 OF ASCE 7-10. | | 1609.3 BASIC WIND SPEED FIGURE 1609.A-C | | 1609.3 WIND SPEED CONVERSION | | 1) THE BASIC WIND SPEED, VU, SHALL BE DETERMINED IN | | ACCORDANCE WITH 1609.3.1 & ASCE 7-10 | | | | 2) AN IMPORTANCE FACTOR, FIGURE 1609 A-C, ASCE 7-10. | | | | 3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN | | ACCORDANCE WITH 1609.4 & ASCE 7-10 | | | | 4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, * | | SHALL BE DETERMINED FROM TABLE 1609.7.2. ASCE 7-10. | | | | 5) COMPONENTS & CLADDING PRESSURES POSITIVE & NEGATIVE | | TABLE 1609.2(2) . | | | | 4) COMPLIED. | | | | PLEASE TAKE NOTE!!!!!!!!!!!!!!!!! | | | | *****CHAPTER 553.80(2)(B) FLORIDA STATUTES *****STATES | | THAT A LOCAL GOVERNMENT SHALL IMPOSE A FEE OF FOUR | | TIMES THE FEE FOR PLAN REVIEW, IF PLANS ARE REJECTED | | THREE | | OR MORE TIMES FOR REPEATED FAILURE TO CORRECT A CODE | | VIOLATION. | | | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | CONSTRUCTION SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2012-12-19 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2012-12-19 |
Time |
10:38 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2012-12-19 |
Time |
10:38 |
Sent To |
|
|
Notes |
2012-12-19 10:43:55 | BUILDING PLAN REVIEW | | PERMIT: 12100355 | | ADD: 825 SOUTHERN BLVD SUITE # 5 | | CONT: MTC REMODELING | | TEL: (561)655-5956 | | | | 2010 FLORIDA BUILDING CODE W | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 3RD REVIEW | | DEC. 19/2012 | | ACTION: DENIED | | | | 1) SEMI -COMPLIED, SEE COMMENT # 2, NOT REVIEWED BY THE | | DESIGNER OF RECORD. SHEET 1 INDICATES THE FRONT JJALOSE | | WINDOWS ABOVE THE STOREFRONT ARE TO BE REPLACED, | | PRODUCT APPROVALS WERE SUBMITTED FOR WINDOW | | REPLACEMENT. | | 2010 FBC-B 1609.1.2 PROTECTION OF WINDOWS. PRODUCT | | APPROVALS SUBMITTED FOR NON-IMPACT GLASS. REQUIRES | | PRODUCT APPROVAL FOR STORM SHUTTERS. | | IS THE STOREFRONT SYSTEM BELOW TTHE EXISTING JALOSIE | | WINDOWS ALSO BEING REPLACED? | | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | (31)(B) WINDOWS | | (31)(E) STORM SHUTTERS | | | | 2) 3RD REQUEST. 2010 FBC 107.3.4.1 PRODUCT APPROVALS. | | THOSE PRODUCTS WHICH ARE REGULATED BY THE DCA RULE | | 9N-03 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | JURISDICTIONAL APPROVAL. | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | SHOP DRAWINGS ETC.. | | | | 3)3RD REQUEST. 2010 FBC-B 1609.1.1 DETERMINATION OF | | WIND DESIGN- CHAPTER 6 OF ASCE 7-10. | | 1609.3 BASIC WIND SPEED FIGURE 1609.A-C | | 1609.3 WIND SPEED CONVERSION | | 1) THE BASIC WIND SPEED, VU, SHALL BE DETERMINED IN | | ACCORDANCE WITH 1609.3.1 & ASCE 7-10 | | | | 2) AN IMPORTANCE FACTOR, FIGURE 1609 A-C, ASCE 7-10. | | | | 3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN | | ACCORDANCE WITH 1609.4 & ASCE 7-10 | | | | 4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, * | | SHALL BE DETERMINED FROM TABLE 1609.7.2. ASCE 7-10. | | | | 5) COMPONENTS & CLADDING PRESSURES POSITVE & NEGATIVE | | TABLE 1609.2(2) . | | | | 3) 2ND REQUEST , SEMI-COMPLIED. NEW 8X11 SHEET | | INDICATING THE REMOVAAL OF DOOR FROM THE HALLWAY WIDTH | | INDICATED AS 3'-6" IS NOT SIGNED NOR SEALED, NOR IS THE | | REVISION THAT IS CLOUDED INDICATING THE REVISION DATE. | | | | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS | | PREPARED BY THE DESIGN PROFESSIONAL AND BEING FILED FOR | | PUBLIC RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE | | DESIGN PROFESSIONAL AFFIXED TO THE DOCUMENT. | | | | FL ADMIN CODE 61G16.003 ARCHITECTS | | | | FROM 2ND REVIEW. NEW COMMENT- THE HALLWAY THAT LEADS | | FROM TTHE FRONT OF THE PHARMACY TO THE BREAKROOM, IN | | THIS REVISION THE SWING OF THE DOOR HAS CHANGED WHICH | | WILL REQUIRE 18" CLEAR ON THE LATCH SIDE OF THE DOOR, | | PLEASE SEE 2010 ACCESSIBILITY CODE FIGURE 404.2.4.1(A). | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | CONSTRUCTION SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2012-12-04 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2012-12-04 |
Time |
11:23 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2012-12-04 |
Time |
11:23 |
Sent To |
|
|
Notes |
2012-12-04 11:31:28 | BUILDING PLAN REVIEW | | PERMIT: 12100355 | | ADD: 825 SOUTHERN BLVD SUITE # 5 | | CONT: MTC REMODELING | | TEL: (561)655-5956 | | | | 2010 FLORIDA BUILDING CODE W | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 2ND REVIEW | | DEC. 04/2012 | | ACTION: DENIED | | | | 1) SHEET 1 INDICATES THE FRONT JJALOSE WINDOWS ABOVE | | THE STOREFRONT ARE TO BE REPLACED, PRODUCT APPROVALS | | WERE SUBMITTED FOR WINDOW REPLACEMENT. | | 2010 FBC-B 1609.1.2 PROTECTION OF WINDOWS. PRODUCT | | APPROVALS SUBMITTED FOR NON-IMPACT GLASS. REQUIRES | | PRODUCT APPROVAL FOR STORM SHUTTERS. | | IS THE STOREFRONT SYSTEM BELOW TTHE EXISTING JALOSIE | | WINDOWS ALSO BEING REPLACED? | | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | (31)(B) WINDOWS | | (31)(E) STORM SHUTTERS | | | | 2) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | SHOP DRAWINGS ETC.. | | | | 3) 2010 FBC-B 1609.1.1 DETERMINATION OF WIND DESIGN- | | CHAPTER 6 OF ASCE 7-10. | | 1609.3 BASIC WIND SPEED FIGURE 1609.A-C | | 1609.3 WIND SPEED CONVERSION | | 1) THE BASIC WIND SPEED, VU, SHALL BE DETERMINED IN | | ACCORDANCE WITH 1609.3.1 & ASCE 7-10 | | | | 2) AN IMPORTANCE FACTOR, FIGURE 1609 A-C, ASCE 7-10. | | | | 3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN | | ACCORDANCE WITH 1609.4 & ASCE 7-10 | | | | 4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, * | | SHALL BE DETERMINED FROM TABLE 1609.7.2. ASCE 7-10. | | | | 5) COMPONENTS & CLADDING PRESSURES POSITVE & NEGATIVE | | TABLE 1609.2(2) . | | | | 3) NEW COMMENT- THE HALLWAY THAT LEADS FROM TTHE FRONT | | OF THE PHARMACY TO THE BREAKROOM, IN THIS REVISION THE | | SWING OF THE DOOR HAS CHANGED WHICH WILL REQUIRE 18" | | CLEAR ON THE LATCH SIDE OF THE DOOR, PLEASE SEE 2010 | | ACCESSIBILITY CODE FIGURE 404.2.4.1(A). | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | CONSTRUCTION SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2012-10-18 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2012-10-18 |
Time |
06:58 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2012-10-17 |
Time |
16:56 |
Sent To |
|
|
Notes |
2012-10-18 07:05:26 | BUILDING PLAN REVIEW | | PERMIT: 12100355 | | ADD: 825 SOUTHERN BLVD SUITE # 5 | | CONT: MTC REMODELING | | TEL: (561)655-5956 | | | | 2010 FLORIDA BUILDING CODE W | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | 2010 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | OCT. 18/2012 | | ACTION: DENIED | | | | 1) SHEET 1 INDICATES THE FRONT JJALOSE WINDOWS ABOVE | | THE STOREFRONT ARE TO BE REPLACED, NO PRODUCT APPROVALS | | WERE SUBMITTED FOR WINDOW REPLACEMENT. | | 2010 FBC-B 1609.1.2 PROTECTION OF WINDOWS. | | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | (31)(B) WINDOWS | | | | 2) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | SHOP DRAWINGS ETC.. | | | | 3) 2010 FBC-B 1609.1.1 DETERMINATION OF WIND DESIGN- | | CHAPTER 6 OF ASCE 7-10. | | 1609.3 BASIC WIND SPEED FIGURE 1609.A-C | | 1609.3 WIND SPEED CONVERSION | | 1) THE BASIC WIND SPEED, VU, SHALL BE DETERMINED IN | | ACCORDANCE WITH 1609.3.1 & ASCE 7-10 | | | | 2) AN IMPORTANCE FACTOR, FIGURE 1609 A-C, ASCE 7-10. | | | | 3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN | | ACCORDANCE WITH 1609.4 & ASCE 7-10 | | | | 4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, * | | SHALL BE DETERMINED FROM TABLE 1609.7.2. ASCE 7-10. | | | | 5) COMPONENTS & CLADDING PRESSURES POSITVE & NEGATIVE | | TABLE 1609.2(2) . | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | CONSTRUCTION SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2013-01-09 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2013-01-09 |
Time |
10:45 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2013-01-09 |
Time |
10:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2012-11-26 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2012-11-26 |
Time |
15:38 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2012-11-26 |
Time |
15:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2012-11-05 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2012-11-05 |
Time |
09:36 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2012-11-05 |
Time |
09:13 |
Sent To |
|
|
Notes |
2012-11-05 09:37:15 | 12100355 | | 823 SOUTHERN BLVD. | | COMMERCIAL RENOVATION | | | | NONMETALLIC-SHEATHED CABLE (ROMEX) IS NOT AN ACCEPTABLE | | WIRING METHOD FOR THIS OCCUPANCY. NEC 334.12 | | ALL RECEPTACLES LOCATED WITH IN SIX FEET OF A SINK MUST | | BE GFCI PROTECTED. NEC 210.8 | | INCLUDE A RISER PLAN SHOWING THE NEW AND EXISTING | | ELECTRIC SERVICE COMPONENTS WITH MAIN DISCONNECT, | | SERVICE GROUNDING, AND LOCATION. NEC 110.26, 215.5 | | PROVIDE A LIGHTING DENSITY CALCULATION SHOWING | | COMPLIANCE WITH THE FLORIDA BUILDING ENERGY CODE | | REQUIREMENTS. FBC ENERGY CONSERVATION 505.3 | | | | ROBERT LECKY | | ELECTRICAL PLANS EXAMINER | | [email protected] | | 561-805-6718 | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2012-11-29 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2012-11-29 |
Time |
11:19 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2012-11-29 |
Time |
11:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2012-10-19 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2012-10-19 |
Time |
11:31 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2012-10-19 |
Time |
11:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2013-01-09 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2013-01-09 |
Time |
13:13 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2013-01-02 |
Time |
09:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2012-12-19 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2012-12-19 |
Time |
11:01 |
Rev Time |
0.00 |
Received By |
tgordon |
Date |
2012-12-11 |
Time |
16:48 |
Sent To |
|
|
Notes |
2012-12-11 16:50:46 | CONTRACTOR SUBMITTED RESPONSES TO BUILDING REVIEW | | BEFORE ALL THE REVIEWS HAD BEEN COMPLETED. PUT WITH | | ORIGINAL PACKAGE. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2012-12-18 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2012-12-18 |
Time |
07:58 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2012-11-20 |
Time |
15:52 |
Sent To |
|
|
Notes |
2012-11-20 15:53:49 | INCOMING SENT TO B-04. JW |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2012-11-05 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2012-11-05 |
Time |
09:36 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2012-10-15 |
Time |
08:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2013-01-07 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2013-01-07 |
Time |
13:52 |
Rev Time |
0.00 |
Received By |
tgordon |
Date |
2013-01-07 |
Time |
13:52 |
Sent To |
|
|
Notes |
2013-01-07 13:53:22 | OUTDOOR AIR 187 CFM'S. PER COOLING LOAD CAL'S. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2012-12-19 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2012-12-19 |
Time |
11:00 |
Rev Time |
0.00 |
Received By |
tgordon |
Date |
2012-12-19 |
Time |
11:00 |
Sent To |
|
|
Notes |
2012-12-19 11:01:46 | SEE NOTES FROM LAST REVIEW 12/17/12 PLEASE CORRECT. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2012-12-17 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2012-12-17 |
Time |
15:59 |
Rev Time |
0.00 |
Received By |
tgordon |
Date |
2012-12-17 |
Time |
15:59 |
Sent To |
|
|
Notes |
2012-12-17 16:19:35 | *** MECHANICAL PLAN CORRECTIONS NEEDED *** | | | | 1) WALL MOUNTED CONDENSER STAND NEEDS TO BE ON THE | | PLANS & SITE SPECIFIC, OR SUBMIT AN UP TO DATE PRODUCT | | APPROVAL FOR THE STAND. FLORIDA DEPARTMENT OF COMMUNITY | | AFFAIRS RULE 9B-72 JAN. 1, 2006. (31) SUB-CATEGORY OF | | PRODUCTS OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE | | PRODUCT APPROVALS: (G) EXTERIOR COOLER, FREEZERS & | | PER-ENGINEERED A/C STANDS.AND 2010 FBC 107.3.4.1 | | PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE REGULATED | | BY THE DCA RULE 9N-03 SHALL BE REVIEWED AND APPROVED IN | | WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL | | FOR JURISDICTIONAL APPROVAL. | | | | 2) AS NOTED IN LAST REVIEW 11/1/12 NOTE #3. PROVIDE | | OUTDOOR AIR CAL'S. PER 2010 FBC/M 403.3. | | | | MECHANICAL PLAN REVIEW BY: | | TOM GORDON (HY-BYRD INC.) (561) 805-6732 | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2012-11-01 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2012-11-01 |
Time |
09:02 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2012-11-01 |
Time |
07:50 |
Sent To |
|
|
Notes |
2012-11-01 09:02:50 | PLANS DENIED | | 1) PROVIDE A DETAIL FROM THE ENGINEER ON THE | | WALL STAND FOR THE CONDENSER. PER SECTION | | 301.12 WIND RESISTANCE 2010 FBC (M) | | 2) REFER TO SECTION 307.2.1 CONDENSATE DISPOSAL. | | 2010 FBC (M) | | 3) PROVIDE FRESH AIR CALCULATIONS PER TABLE 403.3 | | MINIMUM VENTILATION RATES 2010 FBC (M) | | 4) REFER TO SECTION 503.2.4.4 SHUT OFF DAMPER CONTROLS | | ( FOR FRESH AIR) 2010 FLORIDA ENERGY CODE. | | 5) REFER TO SECTION 503.2.1 CALCULATION OF HEATING & | | COOLING LOADS. 2010 FLORIDA ENERGY CODE. | | PLAN REVIEW BY HAROLD MOSER | | 561-805-6732 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2013-01-09 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2013-01-09 |
Time |
13:01 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2013-01-09 |
Time |
13:01 |
Sent To |
|
|
Notes |
2013-01-09 13:01:30 | RE-STAMPED |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2012-12-04 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2012-12-04 |
Time |
15:03 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2012-12-04 |
Time |
14:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2012-10-18 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2012-10-18 |
Time |
13:39 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2012-10-18 |
Time |
13:15 |
Sent To |
|
|
Notes |
2012-10-18 13:42:59 | FBC 2010 EXISTING BUILDING CODE | | FBC 2010 ACCESSIBILITY CODE | | FBC 2010 PLUMBING REVIEW #1 | | DENIED: | | | | PLEASE SHOW SINKS CONNECTING DOWNSTREAM OF RESTROOM WET | | VENT. | | | | 909.1 HORIZONTAL WET VENT PERMITTED. | | ONLY THE FIXTURES WITHIN THE BATHROOM GROUPS SHALL | | CONNECT TO THE WET-VENTED HORIZONTAL BRANCH DRAIN. ANY | | ADDITIONAL FIXTURES SHALL DISCHARGE DOWNSTREAM OF THE | | HORIZONTAL WET VENT. | | | | | | REVIEW BY | | LARRY WAGNER | | CHIEF PLUMBING INSPECTOR | | PHONE # 805-6692 | | EMAIL [email protected] | | FAX # 805-6676 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2012-11-29 |
|
|
Cont ID |
|
Sent By |
mdekle |
Date |
2012-11-29 |
Time |
|
Rev Time |
0.00 |
Received By |
mdekle |
Date |
2012-11-29 |
Time |
15:12 |
Sent To |
|
|
Notes |
2012-11-29 14:29:30 | 11/29/12 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2012-10-24 |
|
|
Cont ID |
|
Sent By |
mdekle |
Date |
2012-10-24 |
Time |
|
Rev Time |
|
Received By |
mdekle |
Date |
2012-10-24 |
Time |
|
Sent To |
|
|
Notes |
|
|