Plan Review Details - Permit 12100213
Plan Review Stops For Permit 12100213
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2012-10-09 Cont ID  
Sent By rlecky Date 2012-10-09 Time 12:54 Rev Time 0.00
Received By rlecky Date 2012-10-09 Time 12:53 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-10-05 Cont ID  
Sent By rlecky Date 2012-10-05 Time 15:59 Rev Time 0.00
Received By rlecky Date 2012-10-05 Time 14:42 Sent To  
Notes
2012-10-05 16:11:01BORAL TILE SEAL UNDERLAYMENT IS LIMITED TO -45 PSF.
 THIS ROOF IS IN EXPOSURE C AND REQUIRES A MINIMUM OF
 -90PSF WIND UPLIFT RESISTANCE. 2010 FBC RESIDENTIAL
 T301.2.(2)
  
  
 ROBERT LECKY
 PLANS EXAMINER
 [email protected]
 561-805-6718
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status P Date 2012-10-09 Cont ID  
Sent By rlecky Date 2012-10-09 Time 12:53 Rev Time 0.00
Received By rlecky Date 2012-10-09 Time 12:53 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-10-05 Cont ID  
Sent By rlecky Date 2012-10-05 Time 16:11 Rev Time 0.00
Received By rlecky Date 2012-10-05 Time 14:42 Sent To  
Notes
***NONE***