|
 |
 |
 |
 |
 |
Plan Review Details - Permit 12100129
Plan Review Stops For Permit 12100129 |
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2012-12-04 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2012-12-04 |
Time |
10:37 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2012-12-04 |
Time |
10:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2012-10-09 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2012-10-09 |
Time |
18:30 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2012-10-09 |
Time |
18:25 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2012-12-04 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2012-12-04 |
Time |
09:52 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2012-12-04 |
Time |
09:12 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2012-10-09 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2012-10-09 |
Time |
11:13 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2012-10-09 |
Time |
10:29 |
Sent To |
E |
|
Notes |
2012-10-09 11:13:18 | 2047 PALM BEACH LAKES BOULEVARD | | PERMIT #12100129 | | MASTER #12030309 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | NONE OF THE ROOM HEAT OR SMOKE DETECTORS ARE SHOWN FROM | | THE ENGINEERING CONSTRUCTION DOCUMENTS (SHEET E6). | | | | NO SUPERVISION IS PROVIDED FOR THE AUTOMATIC SPRINKLER | | SYSTEM OR BACKFLOW PREVENTER. COORDINATE LOCATIONS OF | | TAMPER AND FLOW SWITCHES. | | | | PROVIDE A MANUAL PULL STATION AT THE NURSE CONTROL | | STATION. | | | | NO NOTIFICATION APPLIANCES PROVIDED IN PATIENT TOILET | | #109, STAFF LOCKER #128, AND CORRIDOR #125 (OUTSIDE OF | | OPERATING ROOM #119). | | | | NO NOTIFICATION APPLIANCES LOCATED IN THE OPERATING | | ROOMS. INDICATE THE METHOD FOR ALERTING THE OCCUPANTS | | OF A FIRE ALARM CONDITION. | | | | PER LOCAL AHJ POLICY, DUCT SMOKE DETECTORS SHALL | | INITIATE A GENERAL FIRE ALARM CONDITION. | | | | A CERTIFICATE OF COMPLETION AND A THIRD PARTY | | MONITORING/VERIFICATION (UL OR ETL) CERTIFICATE SHALL | | BE PROVIDED AT TIME OF FINAL FIRE ALARM INSPECTION. | | | | WESLEY JOLIN | | OFFICE OF THE FIRE MARSHAL | | WEST PALM BEACH FIRE RESCUE | | [email protected] | | (561) 805-6730 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2012-12-04 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2012-12-04 |
Time |
10:38 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2012-12-03 |
Time |
15:00 |
Sent To |
|
|
Notes |
2012-12-03 15:01:04 | TO FIRE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2012-10-12 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2012-10-12 |
Time |
14:58 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2012-10-04 |
Time |
16:08 |
Sent To |
|
|
Notes |
2012-10-04 16:08:46 | IN FIRE BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2012-10-12 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2012-10-12 |
Time |
14:58 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2012-10-12 |
Time |
14:54 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |