Plan Review Stops For Permit 12100013 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2013-01-15 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-01-15 |
Time |
07:56 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-01-15 |
Time |
07:56 |
Sent To |
|
|
Notes |
2013-01-15 10:21:09 | 2010 FBC | | | | DENIED BY BUILDING | | | | 1) A FLORIDA LICENSED CONTRACTOR IS REQUIRED. THIS | | OWNER HAS AN OPEN OWNER BUILDER PERMIT FOR A | | RESIDENTIAL REMODEL AT 3213 VINCENT ROAD. FS489.103 (7) | | | | 2) THE ENERGY CALCULATION FORMS ARE REQUIRED TO BE | | SIGNED BY THE OWNER/AGENT PER FBC ENERGY CONSERVATION | | 405.4.2. | | | | 3) THE PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD FOR | | THE PROJECT PER CITY AMENDMENT 107.3.4.1. IF A LETTER | | IS SUBMITTED, THE SPECIFIC PRODUCT NOA NUMBERS OR FL | | NUMBERS ARE REQUIRED TO BE LISTED. THE DESIGNER OF | | RECORD FOR THIS PROJECT IS THE ENGINEER THAT SEALED THE | | STRUCTURAL PLANS. | | | | 4) THE VALUE OF THE PROJECT HAS BEEN INCREASED FROM | | $8,500 TO $13,250.00 BASED ON THE SCOPE OF WORK SHOWN | | ON THE PLANS AND MARSHALL-SWIFT CONSTRUCTION COSTS. | | CITY AMENDMENTS 109.3 | | | | 5) PROOF OF OWNERSHIP IS REQUIRED TO VERIFY THAT THE | | CORRECT OWNER LISTED ON THE PERMIT APPLICATION AND THE | | NOTICE OF COMMENCEMENT. FS 553 & FS 713.001-713.37 | | | | 6) ONE SET OF PLANS NEEDS TO BE SIGNED OUT AND TAKEN TO | | PALM COUNTY FOR IMPACT FEE REVIEW. RETURN THE STAMPED | | PLANS ALONG WITH A COPY OF THE PAID IMPACT FEE RECEIPT | | TO THE CITY BUILDING DEPARTMENT. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2012-12-26 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-12-26 |
Time |
14:22 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-12-26 |
Time |
12:59 |
Sent To |
|
|
Notes |
2012-12-26 14:23:55 | 2010 FBC | | | | DENIED BY BUILDING | | | | 1) SPECIFY THE WIND-SPEED DATA AND EXPOSURE CATEGORY ON | | THE PLANS. FBCR 301.2.1 AND 301.2.1.4.3 (REPEAT | | COMMENT) | | | | 2) PROVIDE STRUCTURAL DETAILS FOR THE WINDOW AND DOOR | | INFILL FRAMING ON THE PLANS. CITY AMENDMENTS 107.2.1 | | BECAUSE THESE SIGNED AND SEALED STRUCTRUAL DETAILS ARE | | ON SEPARATE 8.5" X 11" PAGES AND NOT ON THE PLANS THE | | DESIGN PARAMETERS NEED TO BE SPECIFIED ON THEM. | | | | 3) PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED AND | | APPROVED IN WRITING BY THE DESIGNER OF RECORD FOR THE | | PROJECT PER CITY AMENDMENT 107.3.4.1(REPEAT COMMENT) | | | | 4) THE VALUE OF $8500.00 STATED ON THE APPLICATION | | APPEARS TO BE LOW FOR THE SCOPE OF WORK INDICATED BY | | THE PLANS. FOR PERMITTING PURPOSES, VALUATION OF | | BUILDINGS AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT | | VALUE TO INCLUDE STRUCTURAL, ELECTRICAL, PLUMBING, | | MECHANICAL, INTERIOR FINISHES, DESIGN FEES, OVERHEAD | | AND PROFIT. CITY AMENDMENTS 109.3 (REPEAT COMMENT) | | | | 5) THERE IS AN OPEN OWNER BUILDER PERMIT APPLICATION | | FOR WORK AT ANOTHER ADDRESS LOCATION BY THIS OWNER. THE | | OWNER BUILDER EXEMPTION MAY NOT APPLY AND A CONTRACTOR | | MAY BE REQUIRED IF THE OWNER PLANS TO RENT OR SELL THIS | | PROPERTY WITHIN A YEAR OF COMPLETION OF THE WORK. FS | | 489.103 (REPEAT COMMENT) | | | | 6) THE ENERGY CALCULATION FORMS ARE REQUIRED TO BE | | SIGNED BY THE OWNER/AGENT FBC ENERGY CONSERVATION | | 405.4.2. | | | | 7) PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW THE | | REVIEW COMMENTS HAVE BEEN ADDRESSED. | | | | 8) AN OWNER BUILDER AFFIDAVIT AND PROOF OF OWNERSHIP IS | | REQUIRED, UNLESS A CONTRACTOR IS APPLYING FOR PERMIT. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2012-11-05 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-11-05 |
Time |
11:34 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-11-05 |
Time |
09:24 |
Sent To |
|
|
Notes |
2012-11-05 11:34:34 | 2010 FBC | | | | DENIED BY BUILDING | | | | 1) CITY AMENDMENTS 107.2.1 REQUIRES ALL INFORMATION, | | DRAWINGS, SPECIFICATIONS AND ACCOMPANYING DATA TO BEAR | | THE NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR | | THE DESIGN. PLEASE CORRECT. | | | | 2) SPECIFY THE WIND-SPEED DATA AND EXPOSURE CATEGORY ON | | THE PLANS. FBCR 301.2.1 AND 301.2.1.4.3 | | | | 3) SPECIFY THE COMPONENT AND CLADDING PRESSURE FOR THE | | WALL AREAS ON THE PLANS. FBCR 301.2.1 | | | | 4) PROVIDE STRUCTURAL DETAILS FOR THE WINDOW AND DOOR | | INFILL FRAMING ON THE PLANS. CITY AMENDMENTS 107.2.1 | | | | 5) SPECIFY THE OPENING PRESSURES FOR THE WINDOWS ON THE | | PLANS. FBCR 301.2.1 | | | | 6) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE NEW | | WINDOWS AS REQUIRED BY DCA RULE 9N-3. | | | | 7) SHOW COMPLIANCE WITH FBCR FOR WIND-BORNE DEBRIS | | PROTECTION OF THE NEW WINDOWS AS REQUIRED BY | | FBCR301.2.1.2. | | | | 8) IF STORM PANELS ARE USED, TWO SETS OF PRODUCT | | APPROVALS, KEY PLANS AND INSTALLATION SCHEDULES WILL BE | | REQUIRED. DCA RULE 9N-3 AND CITY AMENDMENT 107.2.1.3 | | | | 9) PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED AND | | APPROVED IN WRITING BY THE DESIGNER OF RECORD FOR THE | | PROJECT PER CITY AMENDMENT 107.3.4.1 | | | | 10) THE SMOKE ALARMS ON THE OUTSIDE OF THE SLEEPING | | ROOMS ARE REQUIRED TO BE LOCATED IN THE IMMEDIATE | | VICINITY OF THE BEDROOMS PER FBCR 314.3. THE SMOKE | | ALARM IN THE KITCHEN DOES NOT MEET THIS REQUIREMENT. | | | | 11) THE KITCHEN IS TYPICALLY NOT AN ACCEPTABLE LOCATION | | DUE TO THE PROXIMITY TO COOKING VAPORS. THE | | MANUFACTURER'S SPECIFICATIONS NORMALLY REQUIRE SMOKE | | ALARMS TO BE LOCATED A MINIMUM DISTANCE FROM THE | | COOKING APPLIANCES. REFER TO THE SMOKE ALARMS LISTING | | INFORMATION. FBCR 314.1 | | | | 12) SHOW COMPLIANCE WITH FBCR 315.1 WHICH REQUIRES | | CARBON MONOXIDE ALARMS WITHIN 10 FEET OF EACH ROOM USED | | FOR SLEEPING PURPOSES. | | | | 13) THE VALUE OF $8500.00 STATED ON THE APPLICATION | | APPEARS TO BE LOW FOR THE SCOPE OF WORK INDICATED BY | | THE PLANS. FOR PERMITTING PURPOSES, VALUATION OF | | BUILDINGS AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT | | VALUE TO INCLUDE STRUCTURAL, ELECTRICAL, PLUMBING, | | MECHANICAL, INTERIOR FINISHES, DESIGN FEES, OVERHEAD | | AND PROFIT. CITY AMENDMENTS 109.3 | | | | 14) IN ORDER TO EXPEDITE PLAN REVIEW TIME WHEN | | RESUBMITTING, PLEASE SUBMIT A RESPONSE LETTER | | INDICATING HOW THE REVIEW COMMENTS HAVE BEEN ADDRESSED. | | | | 15) THERE IS AN OPEN OWNER BUILDER PERMIT APPLICATION | | FOR WORK AT ANOTHER ADDRESS LOCATION BY THIS OWNER. THE | | OWNER BUILDER EXEMPTION MAY NOT APPLY AND A CONTRACTOR | | MAY BE REQUIRED IF THE OWNER PLANS TO RENT OR SELL THIS | | PROPERTY WITHIN A YEAR OF COMPLETION OF THE WORK. FS | | 489.103 | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2012-12-26 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-12-26 |
Time |
14:21 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-12-26 |
Time |
11:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2012-11-05 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-11-05 |
Time |
14:26 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-11-05 |
Time |
14:26 |
Sent To |
|
|
Notes |
2012-11-05 14:26:48 | 2010 FBC & 2008 NEC | | | | ELECTRIC DENIED | | | | 1) SEE BUILDING REVIEW FOR SMOKE ALARM AND CARBON | | MONOXIDE ALARM COMMENTS. FBCR 314 AND 315 | | | | 2) SHOW COMPLIANCE WITH 2008 NEC ARTICLE 406.11 FOR | | TAMPER-RESISTANCE RECEPTACLES. | | | | 3) SHOW COMPLIANCE WITH ART. 210.12 FOR ARC-FAULT | | CIRCUIT-INTERRUPTER (AFCI) REQUIREMENTS. | | | | 4) SHOW COMPLIANCE WITH ART.210.52 (E) (1) FOR THE | | REQUIRED OUTDOOR (GFCI) RECEPTACLE AT THE FRONT OF THE | | DWELLING. | | | | 5) A RECEPTACLE IS REQUIRED IN BEDROOM #5, BETWEEN THE | | DOOR TO THE ROOM AND THE CLOSET DOOR PER ART. 510.52 | | (A) (2). | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
N |
Date |
2012-12-26 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-12-26 |
Time |
12:57 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-12-26 |
Time |
12:57 |
Sent To |
|
|
Notes |
2012-12-26 12:59:24 | SEPARATE PERMITS, APPLICATIONS AND REVIEWS ARE REQUIRED | | FOR THE GAS. |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2012-11-05 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-11-05 |
Time |
09:09 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-11-05 |
Time |
09:09 |
Sent To |
|
|
Notes |
2012-11-05 09:16:15 | 2010 FBC | | | | GAS REVIEW DENIED | | | | 1) THE PLANS SHOW TWO GAS TANKLESS WATER HEATERS ON THE | | EXTERIOR OF THE DWELLING AND AN GAS RANGE IN THE | | KITCHEN. PLEASE SUBMIT TWO SETS OF ISOMETRIC GAS RISER | | DIAGRAMS FOR THE PROJECT. CITY AMENDMENTS 107.3.5.3 | | #12. | | | | 2) SUBMIT TWO COPIES OF THE MANUFACTURES SPECIFICATIONS | | AND LISTINGS FOR THE TANKLESS WATER HEATERS THAT WILL | | BE INSTALLED. FBCR G2404.3 AND G2406.1 | | | | CITY AMENDMENTS 107.2.1 REQUIRES ALL INFORMATION, | | DRAWINGS, SPECIFICATIONS AND ACCOMPANYING DATA TO BEAR | | THE NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR | | THE DESIGN. PLEASE CORRECT. | | | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2013-01-15 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2013-01-15 |
Time |
10:21 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2013-01-14 |
Time |
10:14 |
Sent To |
|
|
Notes |
2013-01-14 10:14:57 | TO R. MCDOUGALS DESK. JW |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2012-12-26 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-12-26 |
Time |
14:55 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-12-13 |
Time |
12:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2012-11-05 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-11-05 |
Time |
14:27 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-10-01 |
Time |
14:16 |
Sent To |
|
|
Notes |
2012-10-01 14:16:43 | SENT TO R5 SHELF FOR REVIEW. JG. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2012-11-05 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-11-05 |
Time |
16:02 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-11-05 |
Time |
16:02 |
Sent To |
|
|
Notes |
2012-11-05 16:05:01 | THE FOYER THAT IS BEING CONVERTED TO A BEDROOM IS SHOWN | | AS AN ENCLOSED PORCH ON THE PROPERTY APPRAISER'S | | RECORDS. AN IMPACT FEE REVIEW BY PALM BEACH COUNTY WILL | | BE REQUIRED. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2012-12-26 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-12-26 |
Time |
13:20 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-12-26 |
Time |
13:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2012-10-25 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2012-10-25 |
Time |
10:22 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2012-10-25 |
Time |
08:15 |
Sent To |
|
|
Notes |
2012-10-25 10:22:16 | PLANS DENIED | | 1) REFER TO SECTION M1602.4 BALANCED RETURN AIR | | 2010 FBC (R) | | 2) PROVIDE DUCT SIZE, CAN SIZE AND CFM ON PLANS. | | PER SECTION 107 FBC 2012 | | 3) PROVIDE EQUIPMENT SCHEDULE ON THE PLANS | | PER SECTION 107 FBC 2012 | | 4) PROVIDE ENERGY CALCULATION WITH THE PLANS. | | PER FLORIDA ENERGY CODE SECTION 403.6.1 EQUIPMENT | | SIZING. | | PLAN REVIEW BY HAROLD MOSER | | 561-805-6732 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2012-12-26 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-12-26 |
Time |
11:46 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-12-26 |
Time |
11:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2012-11-05 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-11-05 |
Time |
08:04 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-11-05 |
Time |
08:04 |
Sent To |
|
|
Notes |
2012-11-05 08:50:23 | 2010 FBC | | PLUMBING DENIED | | | | 1) THE PLUMBING RISER DIAGRAM ON SHEET A-4 SHOWS TWO | | WASHING MACHINE BRANCH DRAINS & VENTS AND THE PLANS | | INDICATE ONE CLOTHES WASHER. CITY AMENDMENTS 107.2.1 | | PLEASE CORRECT. | | | | 2) THE PLUMBING RISER DIAGRAM DOES NOT SHOW THE BRANCH | | DRAIN & VENT FOR THE KITCHEN SINK THAT IS SPECIFIED ON | | THE PLANS. CITY AMENDMENTS 107.2.1 PLEASE CORRECT. | | | | 3) THE DRAIN TRAP AND TRAP ARM FOR THE WASHING MACHINE | | IS REQUIRED TO BE 2" PER FBCR P3201.7 AND THE RISER | | DIAGRAM HAS 1-1/2". PLEASE CORRECT. | | | | 4) CITY AMENDMENTS 107.2.1 REQUIRES ALL INFORMATION, | | DRAWINGS, SPECIFICATIONS AND ACCOMPANYING DATA TO BEAR | | THE NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR | | THE DESIGN. PLEASE CORRECT. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2012-10-05 |
|
|
Cont ID |
|
Sent By |
mdekle |
Date |
2012-10-05 |
Time |
|
Rev Time |
|
Received By |
mdekle |
Date |
2012-10-05 |
Time |
|
Sent To |
|
|
Notes |
|
|