Plan Review Details - Permit 12090745
Plan Review Stops For Permit 12090745
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-10-17 Cont ID  
Sent By jwitmer Date 2012-10-17 Time 11:46 Rev Time 0.00
Received By jwitmer Date 2012-10-17 Time 11:46 Sent To  
Notes
2012-10-17 12:04:07BUILDING PLAN REVIEW
 PERMIT: 12090745
 ADD: 251 MDI
 TEL: (561)346-6916
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 OCT. 17/ 2012
 ACTION: DENIED
  
 THE GREEN HOUSE PLAN SUBMITTED ON SHEET 2 IS CONCEPTUAL
 IN NATURE, A VISUAL ELEMENT FOR A PROSPECTIVE CUSTOMER
 AS WHAT THE STRUCTURE WILL LOOK LIKE, THERE ARE NO
 ELEMENTS TO REVIEW AS FAR AS PLAN REVIEW. A THOROUGH
 REVIEW CAN NOT BE MADE AT THIS TIME, AS A RESULT OF THE
 ADDITIONAL INFORMATION REQUESTED ADDITIONAL COMMENTS
 MAY APPEAR THAT WERE NOT PART OF THIS REVIEW.
  
 1) 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS.
 THE EXAMINATION OF THE DOCUMENTS BY THE
 BUILDING OFFICIAL SHALL INCLUDE THE FOLLOWING MINIMUM
 CRITERIA AND DOCUMENTS: A FLOOR PLAN; SITE
 PLAN; FOUNDATION PLAN; FLOOR/ROOF FRAMING PLAN OR TRUSS
 LAYOUT; ALL FENESTRATION PENETRATIONS;
 FLASHING; AND ROUGH OPENING DIMENSIONS; AND ALL
 EXTERIOR ELEVATIONS:
 107.3.5.1 COMMERCIAL BUILDINGS:
 107.3.5.1.1 BUILDING
 SET BACK/SEPARATION (ASSUMED PROPERTY LINES)
  
 2. OCCUPANCY GROUP AND SPECIAL OCCUPANCY REQUIREMENTS
 SHALL BE DETERMINED.
  
 3. MINIMUM TYPE OF CONSTRUCTION SHALL BE DETERMINED
 (SEE TABLE 503).
  
 4. FIRE-RESISTANT CONSTRUCTION REQUIREMENTS SHALL
 INCLUDE THE FOLLOWING COMPONENTS:
 FIRE-RESISTANT SEPARATIONS
 FIRE-RESISTANT PROTECTION FOR TYPE OF CONSTRUCTION
  
 6. LIFE SAFETY SYSTEMS SHALL BE DETERMINED AND SHALL
 INCLUDE THE FOLLOWING
 REQUIREMENTS:
 OCCUPANT LOAD AND EGRESS CAPACITIESPROTECTION OF
 OPENINGS AND PENETRATIONS OF RATED WALLS
  
 7. OCCUPANCY LOAD/EGRESS REQUIREMENTS SHALL INCLUDE:
 OCCUPANCY LOAD
 GROSS
 NET
 MEANS OF EGRESS
 EXIT
  
 8. STRUCTURAL REQUIREMENTS SHALL INCLUDE:
 SOIL CONDITIONS/ANALYSIS
 TERMITE PROTECTION
 DESIGN LOADS
 WIND REQUIREMENTS
 BUILDING ENVELOPE
 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS.
 (B) WINDOWS
 (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL
 LOUVERS, EFIS SYSTEMS,
 (D) ROOFING PRODUCTS AND ASSEMBLIES
 STRUCTURAL CALCULATIONS (IF REQUIRED)
 FOUNDATION
 WALL SYSTEMS
 ROOF SYSTEMS
  
 10. ACCESSIBILITY REQUIREMENTS SHALL INCLUDE THE
 FOLLOWING:
 SITE REQUIREMENTS
 ACCESSIBLE ROUTE
 TOILET AND BATHING FACILITIES
 DRINKING FOUNTAINS
  
 11) 2405 SLOPED GLAZING AND SKYLIGHTS
 2405.1 SCOPE.
 THIS SECTION APPLIES TO THE INSTALLATION OF GLASS AND
 OTHER TRANSPARENT, TRANSLUCENT OR OPAQUE GLAZING
 MATERIAL INSTALLED AT A SLOPE MORE THAN 15 DEGREES
 (0.26 RAD) FROM THE VERTICAL PLANE, INCLUDING GLAZING
 MATERIALS IN SKYLIGHTS, ROOFS AND SLOPED WALLS.
 2405.2 ALLOWABLE GLAZING MATERIALS AND LIMITATIONS.
 SLOPED GLAZING SHALL BE ANY OF THE FOLLOWING MATERIALS,
 SUBJECT TO THE LISTED LIMITATIONS.
 1. FOR MONOLITHIC GLAZING SYSTEMS, THE GLAZING MATERIAL
 OF THE SINGLE LIGHT OR LAYER SHALL BE LAMINATED GLASS
 WITH A MINIMUM 30-MIL (0.76 MM) POLYVINYL BUTYRAL (OR
 EQUIVALENT) INTERLAYER, WIRED GLASS, LIGHT-TRANSMITTING
 PLASTIC MATERIALS MEETING THE REQUIREMENTS OF SECTION
 2607, HEAT-STRENGTHENED GLASS OR FULLY TEMPERED GLASS.
 2. FOR MULTIPLE-LAYER GLAZING SYSTEMS, EACH LIGHT OR
 LAYER SHALL CONSIST OF ANY OF THE GLAZING MATERIALS
 SPECIFIED IN ITEM 1 ABOVE.
 ANNEALED GLASS IS PERMITTED TO BE USED AS SPECIFIED
 WITHIN EXCEPTIONS 2 AND 3 OF SECTION 2405.3.
 FOR ADDITIONAL REQUIREMENTS FOR PLASTIC SKYLIGHTS, SEE
 SECTION 2610. GLASS-BLOCK CONSTRUCTION SHALL CONFORM TO
 THE REQUIREMENTS OF SECTION 2101.2.5.
  
 12) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2012-11-01 Cont ID  
Sent By rlecky Date 2012-11-01 Time 18:00 Rev Time 0.00
Received By rlecky Date 2012-11-01 Time 17:57 Sent To  
Notes
2012-11-01 18:00:27NO ELECTRICAL PALNS SUBMITTED.

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2012-10-15 Cont ID  
Sent By lfranco Date 2012-10-24 Time 14:10 Rev Time 0.00
Received By bmoree Date 2012-10-15 Time 13:37 Sent To E
Notes
2012-10-15 13:43:461. DRIVEWAY NEEDS STANDARD DETAIL.
 2. SPECIFY DRIVEWAY DIMENSIONS. (WIDTH, LENGTH,
 THICKNESS)
 3. SPECIFIY DRIVEWAY MATERIAL. (CONCRETE, 3,000 PSI,
 FIBER REINFORCED)
  
 BRIAN R. MOREE, MPA
 ENGINEERING CONSTRUCTION MANAGER
 ENGINEERING & PUBLIC WORKS DEPARTMENT
 CITY OF WEST PALM BEACH
 CITY HALL FOURTH FLOOR
 401 CLEMATIS STREET
 WEST PALM BEACH, FLORIDA 33401
 561-494-1098 OFFICE
 561-494-1116 FAX
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2012-10-04 Cont ID  
Sent By wjolin Date 2012-10-04 Time 13:56 Rev Time 0.00
Received By wjolin Date 2012-10-04 Time 13:43 Sent To  
Notes
2012-10-04 13:56:182511 SOUTH DIXIE HIGHWAY
 PERMIT #12090745
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS
 SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE
 TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL
 DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET.
  
 NO ILLUMINATION PROVIDED FOR THE STORAGE ROOM.
  
 PROVIDE ILLUMINATED EXIT SIGNS AND PROVIDE TACTILE
 SIGNAGE AT EXIT DOORS.
  
 ANY AREA (STORAGE) HAVING A DEGREE OF HAZARD GREATER
 THAN NORMAL TO THE GENERAL OCCUPANCY (BUSINESS) OF THE
 BUILDING, SHALL BE SEPARATED FROM NON-STORAGE AREAS
 WITH A 1-HOUR FIRE-RATED BARRIER. DOORS SHALL BE SELF
 CLOSING, POSITIVE LATCHING, AND FIRE-RATED FOR AT LEAST
 45-MINUTES PER SECTION 8.7 OF NFPA 101.
  
 PROVIDE BUILDING ADDRESS VISIBLE FROM THE STREET.
 NUMBERS SHALL BE ATTACHED TO THE BUILDING AND BE AT
 LEAST SIX-INCHES IN HEIGHT WITH 1-INCH STROKE AND SHALL
 CONTRAST THE BACKGROUND
  
 WESLEY JOLIN
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-11-01 Cont ID  
Sent By rlecky Date 2012-11-01 Time 18:01 Rev Time 0.00
Received By rlecky Date 2012-09-28 Time 16:01 Sent To  
Notes
2012-09-28 16:01:45C19

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2012-10-23 Cont ID  
Sent By hmoser Date 2012-10-23 Time 12:16 Rev Time 0.00
Received By hmoser Date 2012-10-23 Time 12:16 Sent To  
Notes
2012-10-23 12:17:58NO MECHANICAL PLANS SUBMITTED
 PLAN REVIEW BY HAROLD MOSER
 561-805-6732
 [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2012-10-17 Cont ID  
Sent By lwagner Date 2012-10-17 Time 12:39 Rev Time 0.00
Received By lwagner Date 2012-10-17 Time 12:16 Sent To  
Notes
2012-10-17 12:39:27FBC 2010 EXISTING BUILDING CODE
 FBC 2010 ACCESSIBILITY CODE
 FBC 2010 PLUMBING REVIEW #1
 DENIED:
  
 1. NO PLUMBING DRAWINGS WERE INCLUDED WITH THIS SET OF
 PLANS.
  
 2. DEPENDING UPON THE OCCUPANCY TYPE AND NUMBER OF
 OCCUPANTS, DRINKING FOUNTAINS MAY BE REQUIRED
 PLUMBING TABLE 403.1 (E) (F)
 FBC ACCESSIBILITY CODE 2010 211.2 MINIMUM NUMBER. NO
 FEWER THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED.
 ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.1 THROUGH
 602.6 AND ONE DRINKING FOUNTAIN SHALL COMPLY WITH
 602.7.
 EXCEPTION: WHERE A SINGLE DRINKING FOUNTAIN COMPLIES
 WITH 602.1 THROUGH 602.6 AND 602.7, IT SHALL BE
 PERMITTED TO BE SUBSTITUTED FOR TWO SEPARATE DRINKING
 FOUNTAINS.
  
 FBC 107.3.5.1.3 PLUMBING MINIMUM PLAN REVIEW CRITERIA
 FOR BUILDINGS.
 1. MINIMUM PLUMBING FACILITIES
 2. FIXTURE REQUIREMENTS
 3. WATER SUPPLY PIPING
 4. SANITARY DRAINAGE
 5. WATER HEATERS
 6. VENTS
 7. ROOF DRAINAGE
 8. BACK FLOW PREVENTION
 13. PLUMBING RISER
  
  
  
 REVIEW BY
 LARRY WAGNER
 CHIEF PLUMBING INSPECTOR
 PHONE # 805-6692
 EMAIL [email protected]
 FAX # 805-6676
  

Review Stop Z ZONING
Rev No 1 Status P Date 2012-10-24 Cont ID  
Sent By lfranco Date 2012-10-05 Time 17:17 Rev Time 0.00
Received By lfranco Date 2012-10-05 Time 17:16 Sent To ENG
Notes
2012-10-24 14:11:35PLANNING: **** PASSED WITH PROVISO, SEPARATE LANDSCAPE
 AND IRRIGATION PERMITS ARE REQUIRED TO BE SUBMITTED AND
 APPROVED, PRIOR TO FINAL C.O. OF THE BUILDING. SUBMIT
 THE INFORMATION BELOW WITH THE LANDSCAPE AND IRRIGATION
 PLANS. ****
  
 1. SEPARATE LANDSCAPE AND IRRIGATION PERMITS ARE
 REQUIRED. TWO (2) COPIES OF THE LANDSCAPE PLAN AND A
 CERTIFIED COST ESTIMATE THAT INCLUDES THE TOTAL COST OF
 ALL LANDSCAPE MATERIALS AND LABOR, BROKEN DOWN INTO
 UNIT COST SHALL BE SUBMITTED WITH THE LANDSCAPE PERMIT
 APPLICATION.
  
 2. SUBMIT TWO (2) COPIES OF THE IRRIGATION PLAN WITH
 THE IRRIGATION PERMIT APPLICATION.
  
  
 IF YOU HAVE ANY QUESTIONS CONTACT ME OR ANGELLA
 JONES-VANN @ (561) 822-1441.
  
 LINDA MIA FRANCO, AICP
 SENIOR PLANNER
 PLANNING DIVISION
 TEL: (561) 822-1443
 EMAIL: [email protected]
  
  
 10/24/12 - BACK TO C19 BIN
2012-10-05 17:16:51PLANNING: **** UNDER REVIEW FWD TO ENGINEERING. RETURN
 BACK TO ZONING. ****