Plan Review Details - Permit 12090628
Plan Review Stops For Permit 12090628
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2012-10-12 Cont ID  
Sent By jwitmer Date 2012-10-12 Time 10:02 Rev Time 0.00
Received By jwitmer Date 2012-10-12 Time 08:05 Sent To  
Notes
2012-10-12 10:34:48 
 BUILDING PLAN REVIEW
 PERMIT: 12090628
 ADD: 5841 CORPORATE WAY
 CONT: FISHER CONTRACTING
 TEL: (561) 691-4716
  
 2010 FLORIDA BUILDING CODE W
 * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS
  
 2010 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
  
 BUILDING PROVISO:
 1) SHEET A1.1 DOOR # 16 A NEW EXTERIOR DOOR WILL
 REQUIRE PRODUCT APPROVAL FOR WIND AND LARGE MISSILE
 IMPACT RESISTANT GLAZING. 2010 FBC-B 1609.1.2
 PROTECTION OF OPENINGS. COMPONENTS AND CLADDING.
 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2012-10-11 Cont ID  
Sent By rlecky Date 2012-10-11 Time 12:05 Rev Time 0.00
Received By rlecky Date 2012-10-11 Time 11:58 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2012-10-04 Cont ID  
Sent By wjolin Date 2012-10-04 Time 14:15 Rev Time 0.00
Received By wjolin Date 2012-10-04 Time 13:57 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-10-16 Cont ID  
Sent By jwitmer Date 2012-10-16 Time 16:53 Rev Time 0.00
Received By jwitmer Date 2012-09-26 Time 10:21 Sent To  
Notes
2012-09-28 10:25:55C12

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2012-10-16 Cont ID  
Sent By jwitmer Date 2012-10-16 Time 16:53 Rev Time 0.00
Received By jwitmer Date 2012-10-16 Time 16:03 Sent To  
Notes
2012-10-16 16:56:50 
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
  
 SHEET M4.1 THE NEW A/C STAND INDICATED ON PLANS NOA
 07-0509.09 IS EXPIRED AND WILL NEED TO BE REVIEWED AS A
 REVISION WITH ASSOCIATED FEES. JW

Review Stop P PLUMBING
Rev No 1 Status P Date 2012-10-05 Cont ID  
Sent By lwagner Date 2012-10-05 Time 10:30 Rev Time 0.00
Received By lwagner Date 2012-10-05 Time 09:46 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2012-10-04 Cont ID  
Sent By ajones Date 2012-10-04 Time 10:13 Rev Time 0.00
Received By ajones Date 2012-10-04 Time 10:13 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved