Plan Review Details - Permit 12090495
Plan Review Stops For Permit 12090495 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2012-10-24 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2012-10-24 |
Time |
16:11 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2012-10-24 |
Time |
16:21 |
Sent To |
|
|
Notes |
2012-10-24 16:20:37 | BUILDING REVIEW APPROVED WITH PROVISO: | | | | 1- CORNER AREAS (4' X 4' MIN.) NEED TO HAVE MIN. 4" | | WIDE STRIPS OF ELASTOFLEX SA-V OVER ALL JOINTS AS | | REQUIRED BY SEC. 5.5.2.3 ON FLORIDA PRODUCT APPROVAL | | FL5259-R16 SUBMITTED. | | | | 2- PER MEETING WITH ROBERT BROWN HURRICANE MITIGATION | | RETROFIT LETTER SUBMITTED BY THE CONTRACTOR AND SIGNED | | BY THE OWNER NEEDS TO HAVE OWNER'S ORIGINAL SIGNATURE | | NEXT TO THE EXISTING OWNER'S SIGNATURE. | 2012-10-24 16:17:26 | 1-CONTRACTOR SUBMITTED PROOF OF HOUSE INSURANCE FOR THE | | SUM OF $572,000. THEREFORE THE 50% OF SUBSTANTIAL | | IMPROVEMENT DOESN'T APPLY. JG. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2012-09-20 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2012-09-20 |
Time |
10:06 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2012-09-20 |
Time |
09:36 |
Sent To |
|
|
Notes |
2012-09-20 10:32:06 | RESIDENTIAL (R3) ROOFING REVISION BUILDING REVIEW | | COMMENTS. | | CODE: 2010 FBC. | | | | 1- ACCORDING TO THE PROPERTY APPRAISER WEBSITE THIS | | PROPERTY IMPROVEMENT VALUE IS $19,146. THIS PROPERTY IS | | LOCATED ON FLOOD ZONE A7. ACCORDING TO THE CITY CODE | | THE PROPERTY NEEDS TO BE 6" ABOVE THE BASE FLOOD | | ELEVATION. SEC. 94-546(A)(3) AND SEC. 94-546(B)(1) OF | | CITY CODE. PROVIDE COPY OF FLOOD ELEVATION CERTIFICATE | | OR SURVEY SHOWING THE FINISH FLOOR ELEVATION OF THE | | HOUSE. IF THE HOUSE FINISH FLOOR ELEVATION IS LESS THAN | | 7'-6", THEN, THE HOUSE NEEDS TO BE RAISED TO COMPLY. | | | | 2- BORAL ROOFING UNDERLAYMENT FL14317-R2 SUBMITTED: | | ACCORDING TO LIMITATION #5.5.2.1 THE MAXIMUM DESIGN | | PRESSURE FOR THIS UNDERLAYMENT IS -45PSF. THIS HOUSE IS | | LOCATED ON EXPOSURE "D" AND THE DESIGN PRESSURES ARE | | HIGHER THAN -45PSF. THEREFORE, THIS PRODUCT APPROVAL | | CAN'T BE USED. PROVIDE OTHER PRODUCT APPROVAL THAT | | MEETS THE DESIGN PRESSURES REQUIRED BY SEC. | | R301.2.1.4.3 OF 2010 FLORIDA RESIDENTIAL CODE. SEC. | | 107.2.1.2 CITY AMENDMENTS TO FBC. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2012-10-24 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2012-10-24 |
Time |
16:11 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2012-10-24 |
Time |
15:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2012-09-20 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2012-09-20 |
Time |
10:06 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2012-09-20 |
Time |
09:36 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |