Plan Review Details - Permit 12090081
Plan Review Stops For Permit 12090081
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2012-10-02 Cont ID  
Sent By jgomez Date 2012-10-02 Time 14:43 Rev Time 0.00
Received By jgomez Date 2012-10-02 Time 13:38 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-09-19 Cont ID  
Sent By jgomez Date 2012-09-19 Time 15:54 Rev Time 0.00
Received By jgomez Date 2012-09-19 Time 09:25 Sent To  
Notes
2012-09-19 16:26:44RESIDENTIAL (R3) ADDITION BUILDING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- PROVIDE ENERGY CALCULATIONS (TWO COPIES) AS REQUIRED
 BY SEC. 103.2 OF 2010 FBC-ENERGY CONSERVATION.
  
 2- AFTER PLANS ARE REVISED, BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD) TO VERIFY IF IMPACT FEES ARE
 DUE. BRING BACK STAMPED PLANS AND COPY OF PAID RECEIPT
 IF FEES ARE DUE. COUNTY IMPACT FEE ORDINANCE OF THE
 UNIFIED LAND DEVELOPMENT CODE.
  
 3- ACCORDING TO PLANS SUBMITTED, PROPOSED LOCATION OF
 THE AIR HANDLER UNIT MAY HAVE NOT ENOUGH ROOM TO COMPLY
 WITH THE APPLIANCE ACCESS REQUIREMENTS OF SEC. M1305 OF
 2010 FLORIDA RESIDENTIAL CODE. CHECK AND REVISE AS
 REQUIRED.
  
 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 DCA RULE 9N-3 FOR:
 A) PRECAST LINTELS AS SPECIFIED ON PLANS.
  
 B) SIMPSON TRUSS CONNECTORS SPECIFIED ON PLANS. PROVIDE
 ONLY THE PRODUCT APPROVAL COVER PAGE AND PAGE SHOWING
 THE CONNECTOR.
  
 C) BORAL ROOFING UNDERLAYMENT. ACCORDING TO FLORIDA
 PRODUCT APPROVAL FL 14317 SUBMITTED THE MAXIMUM DESIGN
 PRESSURES FOR THIS SYSTEM IS -45PSF (SEE LIMITATION
 #5.5.2.1). DESIGN PRESSURES FOR THIS BUILDING FOR ZONE
 2 AND 3 ARE HIGHER THAN -45PSF. (SEE SEC. R301.2.1.3 OF
 2010 FLORIDA RESIDENTIAL CODE). THEREFORE, THIS PRODUCT
 APPROVAL CAN'T BE USED.
  
 5- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS TO FBC.
  
 6- ROOFING CONTRACTOR NEEDS TO APPLY FOR THE ROOFING
 PERMIT. 105.1 CITY AMENDMENTS TO FBC.
  
 7- PLANS NEED TO SPECIFY ATTIC VENTILATION AS REQUIRED
 BY SEC. R806 OF 2010 FLORIDA RESIDENTIAL CODE. SPECIFY
 SIZE AND LOCATION.
  
 8- SHEET S-1:
 A) WIND LOAD SCHEDULE: (1)CLARIFY WHY THE DESIGN IS FOR
 0 TO 7 DEGREES. SEE ROOF PITCH ON PLANS AND REVISE AS
 REQUIRED. (2) REVISE NOTE #2. CORNER DISTANCE IS 4'-0"
 MIN. AS REQUIRED BY FOOTNOTE ON FIGURE R301.2(7) OF
 2010 FLORIDA RESIDENTIAL CODE. AND CLARIFY WHY THE
 TRIBUTARY AREA IS 50SF FOR COMPONENTS AND CLADDING?.
 SEC. 107.2.1.3 CITY AMENDMENTS TO FBC.
  
 B) ROOF SHEATHING NAILING SCHEDULE: REVISE CORNER
 DISTANCE A. ACCORDING TO FIGURE R803.2.3.1 GABLE ENDS
 DISTANCE IS 5'-0' MIN AND ROOF ZONE 2 IS 4'-0" MIN.
 REVISE AS REQUIRED.
  
 C) ROOF DESIGN LOAD SCHEDULE: THE ROOF LIVE LOAD SHALL
 BE DESIGNED AS REQUIRED BY SEC. R301.6 OF 2010 FLORIDA
 RESIDENTIAL CODE. REVISE AS REQUIRED.
  
 9- SHEET S-2: REVISE ROOF SHEATHING SPECIFICATION SHOWN
 ON WALL SECTION 1/S-2 AND 2/S-2 TO MATCH SPECIFICATIONS
 SHOWN ON SHEET S-1. INFORMATION SUBMITTED DON'T MATCH.
 SEC. 107.2.1 CITY AMENDMENTS TO FBC.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2012-10-02 Cont ID  
Sent By rlecky Date 2012-10-02 Time 16:13 Rev Time 0.00
Received By rlecky Date 2012-10-02 Time 15:57 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2012-09-10 Cont ID  
Sent By rlecky Date 2012-09-10 Time 12:02 Rev Time 0.00
Received By rlecky Date 2012-09-10 Time 11:39 Sent To  
Notes
2012-09-10 11:59:41THE FOLLOWING INFORMATION HAS BEEN APPLIED TO THE PLAN.
  
 PROVISO:
 REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO
 INCLUDE INTERCONNECTED SMOKE ALARMS BOTH WITHIN AND
 OUTSIDE EACH SLEEPING AREA. IF THE RESIDENCE HAS GAS
 APPLIANCES, AN ATTACHED GARAGE OR A FIRE PLACE A CARBON
 MONOXIDE DETECTOR IS REQUIRED WITHIN TEN FEET OF EACH
 ROOM USED FOR SLEEPING. 2010 FBC R314, 315
 ARC FAULT CIRCUIT PROTECTION IS REQUIRED FOR ALL NEW
 GENERAL PURPOSE OUTLETS. NEC 210.12
 NEW RECEPTACLES MUST BE TAMPER RESISTANT. NEC 406.11
 THE NEW BATHROOM REQUIRES A DEDICATED 20 AMP BRANCH
 CIRCUIT. NEC 210.11 (C) (3)
  
 ROBERT LECKY
 ELECTRIC PLANS EXAMINER
 [email protected]
 561-805-6718
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2012-10-04 Cont ID  
Sent By jgomez Date 2012-10-04 Time 16:28 Rev Time 0.00
Received By jgomez Date 2012-10-03 Time 16:49 Sent To  
Notes
2012-10-03 16:49:53EXPEDITED
 IN ZONING BOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-10-02 Cont ID  
Sent By jgomez Date 2012-10-02 Time 14:54 Rev Time 0.00
Received By jgomez Date 2012-09-28 Time 17:45 Sent To  
Notes
2012-09-28 17:53:48EXPEDITED
 2ND RUN
 R--19

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-09-19 Cont ID  
Sent By jgomez Date 2012-09-19 Time 16:26 Rev Time 0.00
Received By jgomez Date 2012-09-05 Time 17:34 Sent To  
Notes
2012-09-06 17:43:26EXPEDITED
 R--4

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2012-10-02 Cont ID  
Sent By jgomez Date 2012-10-02 Time 14:53 Rev Time 0.00
Received By jgomez Date 2012-10-02 Time 14:53 Sent To  
Notes
2012-10-02 14:54:23IMPACT FEES PAID. MU-2012-017578-0000.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2012-09-19 Cont ID  
Sent By jgomez Date 2012-09-19 Time 15:52 Rev Time 0.00
Received By jgomez Date 2012-09-19 Time 15:52 Sent To  
Notes
2012-09-19 15:53:48BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD) TO
 VERIFY IF IMPACT FEES ARE DUE. BRING BACK STAMPED PLANS
 AND COPY OF PAID RECEIPT IF FEES ARE DUE.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2012-10-04 Cont ID  
Sent By jgomez Date 2012-10-04 Time 16:27 Rev Time 0.00
Received By jgomez Date 2012-10-04 Time 16:27 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2012-10-02 Cont ID  
Sent By jgomez Date 2012-10-02 Time 14:45 Rev Time 0.00
Received By jgomez Date 2012-10-02 Time 14:45 Sent To  
Notes
2012-10-02 14:46:47RESIDENTIAL (R3) ADDITION SECOND MECHANICAL REVIEW
 COMMENTS.
 CODE: 2010 FBC.
  
 SAME COMMENTS. NO INFORMATION SUBMITTED FOR REVIEW.
  
 1- NO INFORMATION WAS SUBMITTED. NEED TWO COPIES OF
 PLANS AND EQUIPMENT SIZING CALCULATIONS. SEC.
 107.3.5.3(10) OF CITY AMENDMENTS TO FBC.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2012-09-19 Cont ID  
Sent By jgomez Date 2012-09-19 Time 15:48 Rev Time 0.00
Received By jgomez Date 2012-09-19 Time 15:47 Sent To  
Notes
2012-09-19 15:52:33RESIDENTIAL (R3) ADDITION MECHANICAL REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- NO INFORMATION WAS SUBMITTED. NEED TWO COPIES OF
 PLANS AND EQUIPMENT SIZING CALCULATIONS. SEC.
 107.3.5.3(10) OF CITY AMENDMENTS TO FBC.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop P PLUMBING
Rev No 2 Status P Date 2012-10-02 Cont ID  
Sent By jgomez Date 2012-10-02 Time 14:50 Rev Time 0.00
Received By jgomez Date 2012-10-02 Time 14:50 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2012-09-19 Cont ID  
Sent By jgomez Date 2012-09-19 Time 15:35 Rev Time 0.00
Received By jgomez Date 2012-09-19 Time 15:35 Sent To  
Notes
2012-09-19 15:47:49RESIDENTIAL (R3) ADDITION PLUMBING REVIEW COMMENTS.
 CODE: 2010 FBC.
  
 1- PROVIDE PLUMBING RISER DIAGRAM THAT MATCHES FLOOR
 PLAN. SEE LAYOUT OF PLUMBING FIXTURES IN THE FLOOR PLAN
 AND REVISE AS REQUIRED. CLARIFY HOW IS THE LAVATORY
 DRAIN CONNECTED TO THE VENT STACK. ACCORDING TO FLOOR
 PLAN THE MASTER BATHROOM DOOR DOESN'T ALLOW THIS
 CONNECTION. SEC. 107.2.1 CITY AMENDMENTS TO FBC.
 DRAWING NEEDS TO BE CLEAR TO VERIFY COMPLIANCE WITH THE
 VENTING REQUIREMENTS OF SEC. P3108 OF 2010 FLORIDA
 RESIDENTIAL CODE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop Z ZONING
Rev No 3 Status P Date   Cont ID  
Sent By mdekle Date 2012-10-04 Time   Rev Time 0.00
Received By   Date 2012-10-04 Time   Sent To  
Notes
2012-10-04 10:54:15GAVE TO J.G. IN BUILDING - MD

Review Stop Z ZONING
Rev No 2 Status F Date 2012-10-02 Cont ID  
Sent By mdekle Date 2012-10-02 Time   Rev Time 0.00
Received By mdekle Date 2012-10-02 Time   Sent To  
Notes
2012-10-02 13:35:05APPLICANT MUST SUBMIT A SIGNED AND SEALED SURVEY.

Review Stop Z ZONING
Rev No 1 Status F Date 2012-09-13 Cont ID  
Sent By mdekle Date 2012-09-13 Time   Rev Time  
Received By mdekle Date 2012-09-13 Time   Sent To  
Notes
2012-09-13 16:08:46THE APPLICANT MUST SUBMIT A SIGNED AND SEALED SURVEY.