Plan Review Details - Permit 12080136
Plan Review Stops For Permit 12080136 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2012-09-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2012-09-11 |
Time |
12:47 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2012-09-11 |
Time |
12:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2012-08-28 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-08-28 |
Time |
10:26 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-08-28 |
Time |
10:26 |
Sent To |
|
|
Notes |
2012-08-28 10:57:09 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC 2010 RESIDENTIAL | | | | 1. PLAN REVIEW FEES ARE TO BE PAID AT TIME OF | | SUBMITTAL. FAILURE TO PAY PLAN REVIEW FEES WILL RESULT | | IN PERMIT APPLICATION BEING PLACED ON "HOLD" UNTIL FEES | | ARE PAID. | | | | 2. SEE PREVIOUS LISTS, RAS 117 CALCULATIONS REQUIRED | | PER GENERAL LIMITATION #7, LAST PAGE OF NOA FOR THE | | BUILT UP ROOF. REGARDING THE SIGNED AND SEALED DOCUMENT | | PREPARED BY RICHARD LOCKSHIN: | | | | A. RAS 117 NOT SUBMITTED. THE DOCUMENT SUBMITTED ARE | | COMPUTER GENERATED WIND PRESSURE CALCULATIONS, NOT | | REQUIRED FOR BUILDINGS UNDER 60' AS THE TABLE IN FBC | | RESIDENTIAL 2010 301.2(2) AND (3) CAN BE USED TO | | DETERMINE WIND DESIGN PRESSURES. | | | | B. SEE PREVIOUS LIST, TRIBUTARY AREA ON PREVIOUS | | ENGINEERING WAS 100SF AND WAS DENIED WITH A REFERENCE | | TO FBC RESIDENTIAL 301.2(2), NOTE (A). THE MOST RECENT | | SIGNED AND SEALED DOCUMENT DATED 8/15 PREPARED BY | | RICHARD LOCKSHIN CALCULATES THE EFFECTIVE WIND AREA AS | | 420 AND 200 SF. PLEASE SEE FBC 301.2(2), NOTE (A), AND | | REVISE. | | | | C. INCLUDE A TITLE BLOCK WITH ALL INFORMATION REQUIRED | | BY FS 481. | | | | A CALL HAS BEEN PLACED TO THE ARCHITECT IN AN EFFORT TO | | GET THIS ISSUE RESOLVED. | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2012-08-08 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2012-08-08 |
Time |
14:11 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2012-08-08 |
Time |
14:11 |
Sent To |
|
|
Notes |
2012-08-08 16:09:15 | RESIDENTIAL (R3) RE-ROOF SECOND BUILDING REVIEW | | COMMENTS. | | CODE: 2010 FBC. | | | | 1- PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS AS | | REQUIRED BY GENERAL LIMITATION #7 ON LAST PAGE OF NOA | | 07-1219.09 SUBMITTED. NEED THE RAS 117 CALCULATIONS TO | | MEET THE DESIGN PRESSURES REQUIRED BY SEC. R301.2.1.4.3 | | OF 2010 FBC-RESIDENTIAL. | | | | ***NOTE: ENGINEERING CALCULATIONS SUBMITTED ARE MISSING | | THE FOLLOWING: | | | | A) RAS 117 CALCULATIONS WERE NOT SUBMITTED. | | | | B) CALCULATIONS ARE MISSING THE BUILDING EXPOSURE. | | ACCORDING TO SEC. R301.2.1.4.3 THIS BUILDING IS LOCATED | | ON EXPOSURE "C". | | | | C) CALCULATIONS SUBMITTED ARE FOR MONOSLOPE ROOF | | BETWEEN 10 AND 30 DEGREES. NEED CALCULATIONS FOR THE | | FLAT ROOF 0 TO 10 DEGREES. | | | | D) THE TRIBUTARY AREA FOR THE ROOF ZONES IS NOT 100 | | S.F. SEE NOTE (A) OF TABLE R301.2(2) OF 2010 | | FBC-RESIDENTIAL. REVISE AS REQUIRED. | | | | E) SPECIFY THE MEAN ROOF HEIGHT. | | | | F) SPECIFY THE ULTIMATE AND NOMINAL WIND LOADS. | | | | G) ENGINEER TO PROVIDE ALL HIS INFORMATION AS REQUIRED | | BY CHAPTER 471 FLORIDA STATUTE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2012-08-06 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2012-08-06 |
Time |
13:50 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2012-08-06 |
Time |
13:39 |
Sent To |
|
|
Notes |
2012-08-06 13:54:02 | RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS. | | CODE: 2010 FBC. | | | | 1- PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS AS | | REQUIRED BY GENERAL LIMITATION #7 ON LAST PAGE OF NOA | | 07-1219.09 SUBMITTED. NEED THE RAS 117 CALCULATIONS TO | | MEET THE DESIGN PRESSURES REQUIRED BY SEC. R301.2.1.4.3 | | OF 2010 FBC-RESIDENTIAL. | | | | 2- VALUATION IN THE PERMIT APPLICATION WAS UPDATED. | | SEC. 109.3 CITY AMENDMENTS TO FBC. PERMIT FEE BALANCE | | IS $293.31. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2012-09-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2012-09-11 |
Time |
12:46 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2012-09-06 |
Time |
16:07 |
Sent To |
|
|
Notes |
2012-09-06 16:07:34 | INCOMING SENT TO J GOMEZ DESK. JW |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2012-08-08 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2012-08-08 |
Time |
14:10 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2012-08-08 |
Time |
14:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2012-08-06 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2012-08-06 |
Time |
13:39 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2012-08-06 |
Time |
13:39 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |