Plan Review Details - Permit 12070127
Plan Review Stops For Permit 12070127
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2012-09-06 Cont ID  
Sent By lmartine Date 2012-09-06 Time 12:36 Rev Time 0.00
Received By lmartine Date 2012-09-06 Time 12:36 Sent To Z
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-08-09 Cont ID  
Sent By rmcdouga Date 2012-08-09 Time 08:27 Rev Time 0.00
Received By rmcdouga Date 2012-08-07 Time 15:00 Sent To  
Notes
2012-08-07 16:16:312010 FBC
  
 DENIED BY BUILDING
  
 1) THE SCOPE OF WORK ON THE APPLICATION IS FOR
 REPLACING THE WINDOWS WITH IMPACT WINDOWS. BASED ON THE
 PLANS SUBMITTED FOR THE PLUMBING PERMIT, IT APPEARS
 THAT THE EXISTING GARAGE IS BEING CONVERTED TO LIVING
 SPACE TO CREATE A TWO FAMILY DWELLING. THE PBC PROPERTY
 APPRAISER SHOWS A SINGLE FAMILY DWELLING AND A GARAGE
 APARTMENT. UNLESS YOU HAVE PROOF THAT THE GARAGE WAS
 CONVERTED TO LIVING SPACE CREATING A DUPLEX WITH THE
 PROPER PERMITS AND INSPECTIONS, THEN IT IS ASSUMED THAT
 YOU ARE PROPOSING TO CONVERT THE GARAGE APARTMENT INTO
 A TWO FAMILY DWELLING. AN IMPACT FEE REVIEW BY PALM
 BEACH COUNTY WILL BE REQUIRED. PLEASE SUBMIT TWO SETS
 OF PLANS SHOWING THE COMPLETE SCOPE OF THE PROPOSED
 WORK AND PROVIDE AREA TABULATIONS ON THE PLANS. CITY
 AMENDMENTS 107.2.1 IN ADDITION, A REVISION TO THIS
 PERMIT OR A NEW PERMIT APPLICATION MAY BE REQUIRED TO
 INCLUDE THE SCOPE OF WORK REQUIRED TO CONVERT THE
 GARAGE APARTMENT TO A TWO FAMILY DWELLING WITH THE
 APPROPRIATE VALUE FOR THE WORK INDICATED.
  
 2) SUBMIT TWO SETS OF ENERGY CALCULATIONS FOR THE
 DUPLEX SHOWING COMPLIANCE WITH CHAPTER 4 OF THE 2010
 FBC ENERGY CONSERVATION.
  
 3) PROVIDE WALL AND ROOF SECTIONS SHOWING INSULATION,
 FRAMING, VENTING, FINISHES, ETC. CITY AMENDMENTS
 107.2.1
  
 4) SHOW COMPLIANCE WITH FBC R302.3 FOR 1-HOUR FIRE
 RESISTANCE RATED SEPARATION BETWEEN TWO FAMILY
 DWELLINGS FROM THE FOUNDATION TO THE UNDERSIDE OF THE
 ROOF SHEATHING.
  
 5) SHOW COMPLIANCE WITH FBC R311.2 AT THE CONVERTED
 GARAGE FOR THE REQUIRED EGRESS DOOR WITH A MINIMUM 32"
 CLEAR OPENING WIDTH MEASURED FROM THE FACE OF THE DOOR
 TO THE STOP WITH THE DOOR OPEN 90 DEGREES.
  
 6) SHOW COMPLIANCE WITH FBC R310.1 FOR THE EMERGENCY
 ESCAPE AND RESCUE OPENING REQUIRED IN SLEEPING ROOMS.
  
 7) SUBMIT TWO SETS OF DIMENSIONED FLOOR PLANS SHOWING
 COMPLIANCE WITH FBC R307.1 FOR MINIMUM BATHROOM FIXTURE
 CLEARANCES AND R304 MINIMUM ROOM AREAS.
  
 8) SHOW COMPLIANCE WITH FBC R303.3 FOR BATHROOM
 VENTILATION.
  
 9) SHOW COMPLIANCE WITH FBC R305.1 FOR MINIMUM REQUIRED
 CEILING HEIGHT.
  
 10) SHOW COMPLIANCE WITH FBC R314 FOR REQUIRED SMOKE
 ALARMS.
  
 11) IN ORDER TO REDUCE REVIEW TIME, PLEASE SUBMIT A
 RESPONSE LETTER STATING HOW EACH OF THE REVIEW COMMENTS
 WAS ADDRESSED. THANKS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2012-09-06 Cont ID  
Sent By lmartine Date 2012-09-06 Time 12:34 Rev Time 0.00
Received By lmartine Date 2012-09-06 Time 12:34 Sent To  
Notes
2012-09-06 12:36:10SEE #12070143 FOR ELECTRICAL COMMENTS AND APPROVAL

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2012-07-23 Cont ID  
Sent By rlecky Date 2012-07-23 Time 15:04 Rev Time 0.00
Received By rlecky Date 2012-07-23 Time 14:41 Sent To  
Notes
2012-07-23 15:04:26PANEL BOARDS MAY NOT BE LOCATED IN A CLOSET. NEC
 240.24(D)
  
 ROBERT LECKY
 ELECTRIC PLANS EXAMINER
 [email protected]
 561-805-6718
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status N Date 2012-07-10 Cont ID  
Sent By wjolin Date 2012-07-10 Time 11:00 Rev Time 0.00
Received By wjolin Date 2012-07-10 Time 10:47 Sent To  
Notes
2012-07-10 11:00:13APPEARS TO BE A 1 OR 2 FAMILY DWELLING FALLING OUTSIDE
 THE SCOPE OF THE FLORIDA FIRE PREVENTION CODE.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-09-18 Cont ID  
Sent By lmartine Date 2012-09-18 Time 14:02 Rev Time 0.00
Received By lmartine Date 2012-08-29 Time 17:37 Sent To  
Notes
2012-08-29 17:39:11GAVE TO ROBBIE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-08-09 Cont ID  
Sent By rmcdouga Date 2012-08-09 Time 08:27 Rev Time 0.00
Received By rmcdouga Date 2012-07-05 Time 10:02 Sent To  
Notes
2012-07-09 10:13:11SENT TO R3 SHELF FOR REVIEW. JG.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2012-09-18 Cont ID  
Sent By lmartine Date 2012-09-18 Time 14:02 Rev Time 0.00
Received By lmartine Date 2012-09-18 Time 14:02 Sent To  
Notes
2012-09-18 14:03:21PR # MU-2012-017005-0000

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2012-08-07 Cont ID  
Sent By rmcdouga Date 2012-08-07 Time 15:11 Rev Time 0.00
Received By rmcdouga Date 2012-08-07 Time 15:02 Sent To  
Notes
2012-08-07 15:11:41IT APPEARS THAT ADDITIONAL LIVING IS BEING ADDED OR
 BEING CONVERTED FROM STORAGE TO LIVING SPACE. AN IMPACT
 FEE REVIEW BY PALM BEACH COUNTY WILL BE REQUIRED.

Review Stop P PLUMBING
Rev No 2 Status P Date 2012-08-08 Cont ID  
Sent By rmcdouga Date 2012-08-08 Time 14:58 Rev Time 0.00
Received By rmcdouga Date 2012-08-08 Time 14:58 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2012-08-07 Cont ID  
Sent By rmcdouga Date 2012-08-07 Time 15:41 Rev Time 0.00
Received By rmcdouga Date 2012-08-07 Time 15:41 Sent To  
Notes
2012-08-07 16:15:402010 FBC
  
 DENIED BY PLUMBING
  
 1) SUBMIT TWO SETS OF ISOMETRIC (DWV) PLUMBING RISER
 DIAGRAMS THAT SPECIFY THE SIZES OF ALL DRAIN, WASTE AND
 VENT PIPES. CITY AMENDMENTS 107.3.5.3
  
 2) THE PLUMBING PLANS ARE REQUIRED TO HAVE THE ADDRESS
 OF THE PROPERTY OR LOCATION OF THE PROPOSED WORK AND
 THE NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR
 THE DESIGN. CITY AMENDMENTS 107.2.1
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]
2012-07-11 09:44:25WAITING FOR BUILDING REVIEW.

Review Stop Z ZONING
Rev No 2 Status P Date 2012-09-10 Cont ID  
Sent By mdekle Date 2012-09-10 Time   Rev Time 0.00
Received By mdekle Date 2012-09-10 Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2012-08-02 Cont ID  
Sent By lfranco Date 2012-08-02 Time 16:30 Rev Time 0.00
Received By mdekle Date 2012-07-27 Time 17:00 Sent To  
Notes
2012-08-02 16:29:58PLANNING: **** FAILED ***
  
 1. RESPOND TO COMMENTS IN WRITING.
  
 2. PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH
 INCLUDES THE PROPERTY'S ADDRESS AND LEGAL DESCRIPTION.
  
 3. THE ZONING FOR THIS PROPERTY IS SINGLE FAMILY HIGH
 DENSITY ("SF-14"), AND ALLOWS ONE (1) ACCESSORY GARAGE
 APARTMENT, PROVIDED THAT IT MEETS THE ZONING AND LAND
 DEVELOPMENT ("ZLDR"), SECTION 94-273(D)(1). THE
 PROPOSED TWO (2) DWELLING UNITS IN THE ACCESSORY UNIT
 ARE NOT ALLOWED. WHETHER THE UNIT WILL BE RENTED OR
 NOT, THEY COUNT AS TWO (2) DWELLING UNITS.
  
 THE PERMITS FOR THE ADDITIONAL SERVICE PANELS (METERS)
 OR ANY OTHER WORK TO ADD THE ADDITIONAL UNITS WILL NOT
 BE APPROVED, UNTIL ONLY ONE (1) DWELLING UNIT IS SHOWN
 FOR THE ACCESSORY UNIT. THIS INCLUDES, BUT IS NOT
 LIMITED TO THE FOLLOWING PERMITS (12070143),
 (12070128), (12070477).
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME.
  
 LINDA MIA FRANCO, AICP
 SENIOR PLANNER
 PLANNING DIVISION
 TEL: (561) 822-1443
 EMAIL: [email protected]
  
2012-07-27 17:02:33NEED ADDITIONAL INFORMATION, UNDER REVIEW.