 |
Plan Review Details - Permit 12070045
Plan Review Stops For Permit 12070045 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2013-04-01 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-04-01 |
Time |
09:51 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-04-01 |
Time |
09:51 |
Sent To |
|
|
Notes |
2013-04-01 10:15:07 | ****PROVISOS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | 1. SUBMIT AN ARCHITECTURAL QUALITY DETAIL FOR PORCH | | COLUMNS SUBJECT TO FIELD INSPECTOR'S DISCRETION (SUBMIT | | AS REVISION WITH FEES). | | | | 2. SEPARATE PERMIT REQUIRED FOR REROOF AT OWNER'S | | REQUEST. ROOF PERMIT REQUIRED AN INSPECTION PERMIT AS | | THE WORK WAS ALREADY DONE WITHOUT PERMIT OVER EXISTING | | SHINGLES. INSPECTION REQUIRED PRIOR TO ISSUANCE OF ROOF | | OVER PERMIT. | | | | 3. SEPARATE PLUMBING PERMIT REQUIRED (WATER HEATER). | | | | 4. PROVIDE MULLION PRODUCT APPROVAL AT INSPECTION. | | | | 5. PROVIDE DOOR EVALUATION REPORT AND INSTALLATION | | INSTRUCTIONS AT INSPECTION. | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2013-02-26 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-02-26 |
Time |
13:23 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-02-26 |
Time |
13:23 |
Sent To |
|
|
Notes |
2013-02-26 13:28:47 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | COMMENTS NOT ADDRESSED FROM PREVIOUS REVIEWS: | | | | 1. PLANS ARE TO BE ARCHITECTURAL QUALITY, DRAWN TO | | SCALE, WITH ENOUGH INFORMATION TO DETERMINE CODE | | COMPLIANCE, FBC 107.2.1. THE PLAN SUBMITTED IS NOT | | LEGIBLE AND INCLUDES INFORMATION WHICH IS NOT CLEAR | | WHETHER PROPOSED OR EXISTING, SUCH AS A WATER HEATER. | | APPLICATION ALSO ILLEGIBLE; WHAT ARE DECORATED PORCH | | CLONES? DOMES? | | | | 3RD REVIEW, APPLICATION MAKES REFERENCE TO SUPPORT | | COLUMNS AT PORCH, NO DETAIL OR LOCATION PROVIDED ON | | PLAN. | | | | 2. ROOF SHINGLE PRODUCT APPROVALS SUBMITTED, NO ROOFING | | WORK SHOWN? FBC 107.2.1. | | | | 3RD REVIEW, NOT ADDRESSED. | | | | 3. PROVIDE A STRUCTURAL DETAIL FOR THE COLUMN | | REPLACEMENT, FBC 301.1. | | | | 3RD REVIEW, NOT ADDRESSED. | | | | 4. TWO SETS OF PLANS REQUIRED FOR PERMIT ISSUANCE FBC | | 107. | | | | 3RD REVIEW, ONLY ONE SET OF DOOR AND WINDOW PRODUCT | | APPROVALS SUBMITTED. | | | | 5. PROVIDE A COST BREAKDOWN FOR THIS JOB FBC 108.3. | | | | 3RD REVIEW, NOT ADDRESSED. | | | | 6. PROVIDE ROOM DESIGNATIONS FOR THE ROOMS, FBC | | EXISTING BUILDING 604.1. | | | | 3RD REVIEW, PROVIDE INFORMATION REGARDING THE EXISTING | | WINDOWS FOR THE BEDROOMS. THE CLEAR OPENING CANNOT BE | | REDUCED BY MORE THAN 5%. | | | | 7. OK |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2012-09-13 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-09-13 |
Time |
11:22 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-09-13 |
Time |
11:22 |
Sent To |
|
|
Notes |
2012-09-13 11:24:52 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | COMMENTS NOT ADDRESSED FROM PREVIOUS REVIEW: | | | | 1. PLANS ARE TO BE ARCHITECTURAL QUALITY, DRAWN TO | | SCALE, WITH ENOUGH INFORMATION TO DETERMINE CODE | | COMPLIANCE, FBC 107.2.1. THE PLAN SUBMITTED IS NOT | | LEGIBLE AND INCLUDES INFORMATION WHICH IS NOT CLEAR | | WHETHER PROPOSED OR EXISTING, SUCH AS A WATER HEATER. | | APPLICATION ALSO ILLEGIBLE; WHAT ARE DECORATED PORCH | | CLONES? DOMES? | | | | 2. ROOF SHINGLE PRODUCT APPROVALS SUBMITTED, NO ROOFING | | WORK SHOWN? FBC 107.2.1. | | | | 3. PROVIDE A STRUCTURAL DETAIL FOR THE COLUMN | | REPLACEMENT, FBC 301.1. | | | | 4. TWO SETS OF ALL DOCUMENTS REQUIRED FBC 107.2.1. | | | | 5. PROVIDE A COST BREAKDOWN FOR THIS JOB FBC 108.3. | | | | 6. PROVIDE ROOM DESIGNATIONS FOR THE ROOMS, FBC | | EXISTING BUILDING 604.1. | | | | NEW COMMENTS: | | | | 7. A WATER HEATER SPEC WAS PROVIDED WITH THE | | RESUBMITTAL. NEW OR REPLACEMENT? AGAIN, PLAN NOT CLEAR | | AS TO SCOPE. A PLUMBING PERMIT IS REQUIRED FOR WATER | | HEATER NEW INSTALLATION OR REPLACEMENT. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2012-07-09 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-07-09 |
Time |
15:35 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-07-09 |
Time |
15:35 |
Sent To |
|
|
Notes |
2012-07-09 15:36:33 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | 1. PLANS ARE TO BE ARCHITECTURAL QUALITY, DRAWN TO | | SCALE, WITH ENOUGH INFORMATION TO DETERMINE CODE | | COMPLIANCE, FBC 107.2.1. THE PLAN SUBMITTED IS NOT | | LEGIBLE AND INCLUDES INFORMATION WHICH IS NOT CLEAR | | WHETHER PROPOSED OR EXISTING, SUCH AS A WATER HEATER. | | APPLICATION ALSO ILLEGIBLE; WHAT ARE DECORATED PORCH | | CLONES? DOMES? | | | | 2. ROOF SHINGLE PRODUCT APPROVALS SUBMITTED, NO ROOFING | | WORK SHOWN? FBC 107.2.1. | | | | 3. PROVIDE A STRUCTURAL DETAIL FOR THE COLUMN | | REPLACEMENT, FBC 301.1. | | | | 4. TWO SETS OF ALL DOCUMENTS REQUIRED FBC 107.2.1. | | | | 5. PROVIDE A COST BREAKDOWN FOR THIS JOB FBC 108.3. | | | | 6. PROVIDE ROOM DESIGNATIONS FOR THE ROOMS, FBC | | EXISTING BUILDING 604.1. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2013-04-01 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-04-01 |
Time |
11:08 |
Rev Time |
0.00 |
Received By |
shill |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2013-02-26 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2013-02-26 |
Time |
13:28 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2013-02-21 |
Time |
14:01 |
Sent To |
|
|
Notes |
2013-02-22 14:02:17 | SENT TO SAMANTHA'S DESK FOR REVIEW. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2012-09-13 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-09-13 |
Time |
11:25 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-09-11 |
Time |
13:30 |
Sent To |
|
|
Notes |
2012-09-11 13:30:23 | TO SH DESK | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2012-07-09 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-07-09 |
Time |
15:50 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-07-03 |
Time |
09:25 |
Sent To |
|
|
Notes |
2012-07-03 09:26:11 | INCOMING SENT TO MISC BOX # 1. JW |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |