Plan Review Stops For Permit 12060867 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2012-08-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-08-24 |
Time |
10:43 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-08-24 |
Time |
10:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2012-08-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-08-13 |
Time |
08:49 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-08-13 |
Time |
08:49 |
Sent To |
|
|
Notes |
2012-08-13 09:01:58 | DENIED BY BUILDING | | | | 1) SUBMIT TWO SETS OF RAS 117 CALCULATIONS FOR THE GAF | | MODIFIED ROOF SYSTEM FOR THE FLAT DECK ON THE SECOND | | FLOOR ADDITION. FBC R905.11 | | | | 2) THE OWNER/AGENT IS REQUIRED TO SIGN THE ENERGY | | CALCULATION FORMS. FBC ENERGY CONSERVATION SECTION | | 401.2 | | | | 3) ONE SET OF THE PLANS NEED TO BE TAKEN TO PALM BEACH | | COUNTY FOR THE IMPACT FEE REVIEW. THE PLANS WITH THE | | COUNTY REVIEW STAMP AND A COPY OF THE PAID RECEIPT ARE | | REQUIRED TO BE RETURNED TO THE CITY BUILDING DEPARTMENT | | BEFORE THE BUILDING PERMIT CAN BE ISSUED. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2012-07-18 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-07-18 |
Time |
09:01 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-07-13 |
Time |
14:55 |
Sent To |
|
|
Notes |
2012-07-18 09:00:56 | DENIED BY BUILDING | | | | 1) SHOW COMPLIANCE WITH FBC R806.1 FOR REQUIRED ROOF | | VENTILATION. | | | | 2) SUBMIT TWO COPIES OF ENERGY CALCULATIONS THAT HAVE | | BEEN SIGNED BY THE PREPARER AND THE OWNER AGENT AS | | REQUIRED BY FBC ENERGY CONSERVATION SECTION 401.2. | | | | 3) SPECIFY THE SIZES OF THE ROOF SCUPPERS AND OVERFLOW | | SCUPPERS ON SHEET S.01 OF THE PLANS. FBC R903.4.1 AND | | FBC PLUMBING 1106.7 AND 1107.3 | | | | 4) THE COMPONENT AND CLADDING PRESSURES ON SHEET S.01 | | IS SPECIFIED AS + / - 64 PSF WORST CASE AND A 6 FEET | | MINIMUM EDGE STRIP. HOWEVER, THE DIAGRAM AND ANOTHER | | LOCATION SPECIFIES EDGE ZONE PRESSURES AS + 49.42 PSF | | AND - 66.08 PSF. THE PRODUCT APPROVAL DESIGN PRESSURES | | FOR THE DOORS AND WINDOWS ARE + 55 PSF AND - 65 PSF. | | THE + 64 PSF FROM THE FIRST AND THE - 66.08 PSF EXCEEDS | | THE DESIGN PRESSURES OF THE PRODUCT APPROVALS. PLEASE | | CLARIFY AND PROVIDE THE COMPONENT AND CLADDING | | PRESSURES THAT ARE SPECIFIC TO THIS PROJECT. CITY | | AMENDMENTS 107.2.1 AND FBC R301.2.1 | | | | 5) SPECIFY THE METHOD OF ATTACHMENT THAT WILL BE USED | | TO INSTALL THE CLAY ROOF TILE AND PROVIDE TWO COPIES OF | | APPROVALS FOR THE ADHESIVE OR MORTAR PRODUCT THAT WILL | | BE USED. FBC R905.3.7 | | | | 6) SPECIFY THE FASTENING OPTION FROM THE PRODUCT | | APPROVAL THAT WILL BE USED TO INSTALL THE GAF MODIFIED | | BITUMEN ROOF SYSTEM AND SUBMIT TWO COPIES OF SIGNED AND | | SEALED RAS 117 CALCULATIONS FOR ENHANCED FASTENING AT | | THE CORNER AND PERIMETER AREAS AS REQUIRED BY | | LIMITATION NUMBER 7 ON PAGE 31 OF THE NOA. FBC R905.11 | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2012-07-09 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2012-07-09 |
Time |
15:47 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2012-07-09 |
Time |
12:25 |
Sent To |
|
|
Notes |
2012-07-09 15:47:45 | SEE NOTES ON PLAN |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2012-06-29 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2012-06-29 |
Time |
16:21 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2012-06-29 |
Time |
16:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
F |
Date |
2012-08-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-08-13 |
Time |
09:02 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-07-27 |
Time |
17:39 |
Sent To |
|
|
Notes |
2012-07-27 17:39:43 | TO RM DESK | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2012-07-18 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-07-18 |
Time |
09:01 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-06-29 |
Time |
08:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
P |
Date |
2012-08-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-08-24 |
Time |
12:22 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-08-24 |
Time |
12:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2012-08-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-08-13 |
Time |
09:02 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2012-07-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-07-13 |
Time |
16:07 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-07-13 |
Time |
16:07 |
Sent To |
|
|
Notes |
2012-07-13 16:09:44 | PLANS WILL REQUIRE AN IMPACT FEE REVIEW BY PALM BEACH | | COUNTY PRIOR TO PERMIT ISSUANCE. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2012-08-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-08-13 |
Time |
08:49 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-08-13 |
Time |
08:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2012-07-18 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-07-18 |
Time |
08:18 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-07-18 |
Time |
08:18 |
Sent To |
|
|
Notes |
2012-07-18 08:31:37 | 2010 FBC | | | | DENIED BY MECHANICAL | | | | 1) SUBMIT TWO COPIES OF ENERGY CALCULATIONS FOR THE | | ADDITION AS REQUIRED BY THE 2010 FBC ENERGY | | CONSERVATION SECTION 401.2. | | | | 2) SUBMIT TWO COPIES OF EQUIPMENT SIZING CALCULATIONS | | FOR THE HEATING AND COOLING EQUIPMENT AS REQUIRED BY | | FBCR M1401.3. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2012-07-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-07-13 |
Time |
16:07 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-07-13 |
Time |
16:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2012-06-29 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2012-06-29 |
Time |
16:21 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2012-06-29 |
Time |
16:21 |
Sent To |
|
|
Notes |
2012-06-29 16:21:57 | PUT IN RESIDENTIAL INCOMING |
|
|