Plan Review Details - Permit 12060867
Plan Review Stops For Permit 12060867
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2012-08-24 Cont ID  
Sent By rmcdouga Date 2012-08-24 Time 10:43 Rev Time 0.00
Received By rmcdouga Date 2012-08-24 Time 10:43 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2012-08-13 Cont ID  
Sent By rmcdouga Date 2012-08-13 Time 08:49 Rev Time 0.00
Received By rmcdouga Date 2012-08-13 Time 08:49 Sent To  
Notes
2012-08-13 09:01:58DENIED BY BUILDING
  
 1) SUBMIT TWO SETS OF RAS 117 CALCULATIONS FOR THE GAF
 MODIFIED ROOF SYSTEM FOR THE FLAT DECK ON THE SECOND
 FLOOR ADDITION. FBC R905.11
  
 2) THE OWNER/AGENT IS REQUIRED TO SIGN THE ENERGY
 CALCULATION FORMS. FBC ENERGY CONSERVATION SECTION
 401.2
  
 3) ONE SET OF THE PLANS NEED TO BE TAKEN TO PALM BEACH
 COUNTY FOR THE IMPACT FEE REVIEW. THE PLANS WITH THE
 COUNTY REVIEW STAMP AND A COPY OF THE PAID RECEIPT ARE
 REQUIRED TO BE RETURNED TO THE CITY BUILDING DEPARTMENT
 BEFORE THE BUILDING PERMIT CAN BE ISSUED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-07-18 Cont ID  
Sent By rmcdouga Date 2012-07-18 Time 09:01 Rev Time 0.00
Received By rmcdouga Date 2012-07-13 Time 14:55 Sent To  
Notes
2012-07-18 09:00:56DENIED BY BUILDING
  
 1) SHOW COMPLIANCE WITH FBC R806.1 FOR REQUIRED ROOF
 VENTILATION.
  
 2) SUBMIT TWO COPIES OF ENERGY CALCULATIONS THAT HAVE
 BEEN SIGNED BY THE PREPARER AND THE OWNER AGENT AS
 REQUIRED BY FBC ENERGY CONSERVATION SECTION 401.2.
  
 3) SPECIFY THE SIZES OF THE ROOF SCUPPERS AND OVERFLOW
 SCUPPERS ON SHEET S.01 OF THE PLANS. FBC R903.4.1 AND
 FBC PLUMBING 1106.7 AND 1107.3
  
 4) THE COMPONENT AND CLADDING PRESSURES ON SHEET S.01
 IS SPECIFIED AS + / - 64 PSF WORST CASE AND A 6 FEET
 MINIMUM EDGE STRIP. HOWEVER, THE DIAGRAM AND ANOTHER
 LOCATION SPECIFIES EDGE ZONE PRESSURES AS + 49.42 PSF
 AND - 66.08 PSF. THE PRODUCT APPROVAL DESIGN PRESSURES
 FOR THE DOORS AND WINDOWS ARE + 55 PSF AND - 65 PSF.
 THE + 64 PSF FROM THE FIRST AND THE - 66.08 PSF EXCEEDS
 THE DESIGN PRESSURES OF THE PRODUCT APPROVALS. PLEASE
 CLARIFY AND PROVIDE THE COMPONENT AND CLADDING
 PRESSURES THAT ARE SPECIFIC TO THIS PROJECT. CITY
 AMENDMENTS 107.2.1 AND FBC R301.2.1
  
 5) SPECIFY THE METHOD OF ATTACHMENT THAT WILL BE USED
 TO INSTALL THE CLAY ROOF TILE AND PROVIDE TWO COPIES OF
 APPROVALS FOR THE ADHESIVE OR MORTAR PRODUCT THAT WILL
 BE USED. FBC R905.3.7
  
 6) SPECIFY THE FASTENING OPTION FROM THE PRODUCT
 APPROVAL THAT WILL BE USED TO INSTALL THE GAF MODIFIED
 BITUMEN ROOF SYSTEM AND SUBMIT TWO COPIES OF SIGNED AND
 SEALED RAS 117 CALCULATIONS FOR ENHANCED FASTENING AT
 THE CORNER AND PERIMETER AREAS AS REQUIRED BY
 LIMITATION NUMBER 7 ON PAGE 31 OF THE NOA. FBC R905.11
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2012-07-09 Cont ID  
Sent By rlecky Date 2012-07-09 Time 15:47 Rev Time 0.00
Received By rlecky Date 2012-07-09 Time 12:25 Sent To  
Notes
2012-07-09 15:47:45SEE NOTES ON PLAN

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2012-06-29 Cont ID  
Sent By fmittner Date 2012-06-29 Time 16:21 Rev Time 0.00
Received By fmittner Date 2012-06-29 Time 16:21 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status F Date 2012-08-13 Cont ID  
Sent By rmcdouga Date 2012-08-13 Time 09:02 Rev Time 0.00
Received By rmcdouga Date 2012-07-27 Time 17:39 Sent To  
Notes
2012-07-27 17:39:43TO RM DESK
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-07-18 Cont ID  
Sent By rmcdouga Date 2012-07-18 Time 09:01 Rev Time 0.00
Received By rmcdouga Date 2012-06-29 Time 08:38 Sent To  
Notes
2012-07-02 08:39:16R05

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2012-08-24 Cont ID  
Sent By rmcdouga Date 2012-08-24 Time 12:22 Rev Time 0.00
Received By rmcdouga Date 2012-08-24 Time 12:22 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2012-08-13 Cont ID  
Sent By rmcdouga Date 2012-08-13 Time 09:02 Rev Time 0.00
Received By rmcdouga Date   Time   Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2012-07-13 Cont ID  
Sent By rmcdouga Date 2012-07-13 Time 16:07 Rev Time 0.00
Received By rmcdouga Date 2012-07-13 Time 16:07 Sent To  
Notes
2012-07-13 16:09:44PLANS WILL REQUIRE AN IMPACT FEE REVIEW BY PALM BEACH
 COUNTY PRIOR TO PERMIT ISSUANCE.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2012-08-13 Cont ID  
Sent By rmcdouga Date 2012-08-13 Time 08:49 Rev Time 0.00
Received By rmcdouga Date 2012-08-13 Time 08:49 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2012-07-18 Cont ID  
Sent By rmcdouga Date 2012-07-18 Time 08:18 Rev Time 0.00
Received By rmcdouga Date 2012-07-18 Time 08:18 Sent To  
Notes
2012-07-18 08:31:372010 FBC
  
 DENIED BY MECHANICAL
  
 1) SUBMIT TWO COPIES OF ENERGY CALCULATIONS FOR THE
 ADDITION AS REQUIRED BY THE 2010 FBC ENERGY
 CONSERVATION SECTION 401.2.
  
 2) SUBMIT TWO COPIES OF EQUIPMENT SIZING CALCULATIONS
 FOR THE HEATING AND COOLING EQUIPMENT AS REQUIRED BY
 FBCR M1401.3.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop P PLUMBING
Rev No 1 Status P Date 2012-07-13 Cont ID  
Sent By rmcdouga Date 2012-07-13 Time 16:07 Rev Time 0.00
Received By rmcdouga Date 2012-07-13 Time 16:07 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2012-06-29 Cont ID  
Sent By fmittner Date 2012-06-29 Time 16:21 Rev Time 0.00
Received By fmittner Date 2012-06-29 Time 16:21 Sent To  
Notes
2012-06-29 16:21:57PUT IN RESIDENTIAL INCOMING


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved