Plan Review Details - Permit 12060179
Plan Review Stops For Permit 12060179 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2012-11-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-11-14 |
Time |
15:51 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-11-14 |
Time |
15:51 |
Sent To |
|
|
Notes |
2012-11-14 16:38:59 | PROVISO - ROOF PANELS TO BE A MINIMUM OF 3' FROM | | PROPERTY LINE | | FBC RES 302 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2012-10-15 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-10-15 |
Time |
16:45 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-10-15 |
Time |
16:45 |
Sent To |
|
|
Notes |
2012-10-15 16:48:33 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | COMMENTS FROM PREVIOUS LIST, NOT ADDRESSED: | | | | 1. OK | | | | 2. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED FOR | | ROOF PANELS, FAC9N-3. | | | | 3. SEE FBC RESIDENTIAL TABLE 302.1 FOR SEPARATION | | REQUIREMENTS. PROVIDE FIRE RESISTANCE INFORMATION AS | | REQUIRED BY THE TABLE. | | | | 2ND REVIEW, THE SITE PLAN PROVIDED SHOWS ENCROACHMENT | | OVER THE PROPERTY LINE. PROVIDE A SITE PLAN WHICH SHOWS | | PROPOSED CONSTRUCTION (AS PLAN SHOWS REMOVAL OF PORTION | | OF IMPROVEMENT WHICH ENCROACHES THE PROPERTY LINE). | | | | SECTION A-A SHOWS A PROJECTION AND COLUMNS, AND SITE | | PLAN SHOWS A SHED, WHICH ARE LESS THAN 3' FROM THE | | PROPERTY LINE, SEE FBC RESIDENTIAL TABLE R302.1, FIRE | | RESISTANCE REQUIRED. | | | | 4. VALUE IS TO INCLUDE LABOR AND MATERIALS, FBC 108.3. | | | | NEW COMMENT: | | | | 5. THE SURVEY SHOWS A SHED; NO INFORMATION PROVIDED. | | PROVIDE STRUCTURAL INFORMATION, FBC R 301. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2012-07-12 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-07-12 |
Time |
09:18 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-07-12 |
Time |
09:18 |
Sent To |
|
|
Notes |
2012-07-12 10:19:48 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | 1. THE STRUCTURAL PLAN SUBMITTED IS EXTREMELY | | CONFUSING. A PLAN PREPARED BY GUS TARNOWSKI, PE WAS | | SIGNED AND SEALED BY RIZA ALTAN, PE WITH THE LANGUAGE | | "FOR REFERENCE ONLY." WHO IS TAKING RESPONSIBILITY FOR | | THE DESIGN OF THIS STRUCTURE? IF RIZA ALTAN IS TAKING | | OVER THE WORK OF TARNOWSKI, HAS MR. TARNOWSKI BEEN | | ADVISED AS REQUIRED BY FAC 61G15-27.001? IN THE CASE OF | | A SUCCESSOR ENGINEER REUSING ANOTHER ENGINEER'S PLAN, | | THE OTHER ENGINEER'S TITLE BLOCK SHOULD BE REMOVED AND | | THE SUCCESSOR ENGINEER'S TITLE BLOCK INCLUDED. OR, IS | | MR. RIZA AN EMPLOYEE OF TARNOWSKI ENGINEERING, AND | | AUTHORIZED TO USE THAT TITLE BLOCK? THE TITLE BLOCK | | SHOULD ALSO INCLUDE THE PRINTED NAME AND LICENSE NUMBER | | OF THE INDIVIDUAL SEALING THE PLAN. THE SEAL SHOULD | | INCLUDE A DATE. | | | | A STRUCTURAL PLAN TO SHOW HOW THIS IMPROVEMENT COMPLIES | | WITH FBC RESIDENTIAL 301.1, WIND LOADS, IS REQUIRED. | | | | 2. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED FOR | | ROOF PANELS, FAC9N-3. | | | | 3. SEE FBC RESIDENTIAL TABLE 302.1 FOR SEPARATION | | REQUIREMENTS. PROVIDE FIRE RESISTANCE INFORMATION AS | | REQUIRED BY THE TABLE. | | | | 4. VALUE IS TO INCLUDE LABOR AND MATERIALS, FBC 108.3. | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2012-11-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-11-14 |
Time |
16:39 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-10-24 |
Time |
17:51 |
Sent To |
|
|
Notes |
2012-10-24 17:52:02 | IN ZONING BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2012-10-15 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-10-15 |
Time |
16:48 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-09-28 |
Time |
11:05 |
Sent To |
|
|
Notes |
2012-09-28 11:05:59 | INCOMING SENT TO ZONING BOX. JW |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2012-07-12 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-07-12 |
Time |
10:19 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-06-08 |
Time |
11:09 |
Sent To |
|
|
Notes |
2012-06-08 11:09:52 | TO ZONING |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2012-11-01 |
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
2012-10-25 |
Time |
|
Sent To |
|
|
Notes |
2012-11-01 13:04:27 | GAVE TO S.H. - MD |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2012-10-12 |
|
|
Cont ID |
|
Sent By |
lfranco |
Date |
2012-10-12 |
Time |
15:17 |
Rev Time |
0.00 |
Received By |
lfranco |
Date |
2012-09-28 |
Time |
|
Sent To |
|
|
Notes |
2012-10-12 15:26:19 | PERMIT ROUTED TO LF ON 10/3/12 BY MD | | | | PLANNING : **** FAILED **** | | | | | | 1. RESPOND TO COMMENTS IN WRITING. | | | | 2. PURSUANT TO THE ZONING CODE, SECTION 94-305(5), AN | | AWNING SHALL NOT PROJECT MORE THAN FOUR (4) FEET INTO | | ANY SETBACK OR BE SUPPORTED BY ANY MEANS OTHER THAN | | ATTACHMENT TO THE BUILDING. THE MINIMUM SIDE SETBACK IS | | FIVE (5) FEET FOR THE BUILDING, THEREFORE, THE AWNING | | CAN ENCROACH UP TO ONE (1) FOOT AWAY FROM THE PROPERTY | | LINE, HOWEVER, THE AWNING IS SUPPORTED BY COLUMNS, | | THEREFORE, IT CANNOT ENCROACH AS PROPOSED ON THE | | SURVEY. | | | | PURSUANT TO SECTION 94-305(2), STRUCTURAL INTRUSIONS - | | THE COLUMNS (POSTS) SHALL NOT EXTEND NO FURTHER THAN | | THREE (3) FEET INTO ANY SETBACK. | | | | RESUBMITTAL: THE SURVEY SHOWS THAT THE SHED IS | | ENCROACHING ON THE PROPERTY LINE. IT NEEDS TO BE | | REMOVED. THE COVERED AREA, AWNING, IS ALSO ENCROACHING | | ON THE PROPERTY LINE. THE POSTS ARE OVER THE PROPERTY | | LINE OR IMMEDIATELY ADJACENT TO THE PROPERTY LINE. THE | | POSTS AS NOTED ON THE COMMENT ABOVE SHALL NOT EXTEND NO | | FURTHER THAN THREE (3) FEET INTO ANY SETBACK. STAFF HAS | | PREVIOUSLY MET WITH CONTRACTOR (STUART LEDIS) TO | | EXPLAIN THE ISSUE WITH THE LOCATION OF THE PROPERTY | | BASED ON THE SURVEY. THE CITY RECOGNIZES THE SURVEY AS | | A LEGAL INSTRUMENT THAT DEPICTS THE PROPERTY LINES AND | | HAS BEEN REVIEWED BY THE VINCE NOEL THE CITY SURVEYOR | | WHO ALSO AGREES WITH THE LEGAL DESCRIPTION OF THE | | SURVEY. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME. | | | | LINDA MIA FRANCO, AICP | | SENIOR PLANNER | | PLANNING DIVISION | | TEL: (561) 822-1443 | | EMAIL: [email protected] | | | | GIVEN TO LF ON 10/3/12 BY MD |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2012-06-15 |
|
|
Cont ID |
|
Sent By |
lfranco |
Date |
2012-06-15 |
Time |
16:54 |
Rev Time |
0.00 |
Received By |
lfranco |
Date |
2012-06-08 |
Time |
15:33 |
Sent To |
|
|
Notes |
2012-06-15 17:28:08 | PLANNING : **** FAILED **** | | | | | | 1. RESPOND TO COMMENTS IN WRITING. | | | | 2. PURSUANT TO THE ZONING CODE, SECTION 94-305(5), AN | | AWNING SHALL NOT PROJECT MORE THAN FOUR (4) FEET INTO | | ANY SETBACK OR BE SUPPORTED BY ANY MEANS OTHER THAN | | ATTACHMENT TO THE BUILDING. THE MINIMUM SIDE SETBACK IS | | FIVE (5) FEET FOR THE BUILDING, THEREFORE, THE AWNING | | CAN ENCROACH UP TO ONE (1) FOOT AWAY FROM THE PROPERTY | | LINE, HOWEVER, THE AWNING IS SUPPORTED BY COLUMNS, | | THEREFORE, IT CANNOT ENCROACH AS PROPOSED ON THE | | SURVEY. | | | | PURSUANT TO SECTION 94-305(2), STRUCTURAL INTRUSIONS - | | THE COLUMNS SHALL NOT EXTEND NO FURTHER THAN THREE (3) | | FEET INTO ANY SETBACK. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME. | | | | LINDA MIA FRANCO, AICP | | SENIOR PLANNER | | PLANNING DIVISION | | TEL: (561) 822-1443 | | EMAIL: [email protected] | | | 2012-06-08 15:34:07 | GIVEN TO LF |
|
|
|