Plan Review Details - Permit 12060179
Plan Review Stops For Permit 12060179
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2012-11-14 Cont ID  
Sent By shill Date 2012-11-14 Time 15:51 Rev Time 0.00
Received By shill Date 2012-11-14 Time 15:51 Sent To  
Notes
2012-11-14 16:38:59PROVISO - ROOF PANELS TO BE A MINIMUM OF 3' FROM
 PROPERTY LINE
 FBC RES 302

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2012-10-15 Cont ID  
Sent By shill Date 2012-10-15 Time 16:45 Rev Time 0.00
Received By shill Date 2012-10-15 Time 16:45 Sent To  
Notes
2012-10-15 16:48:33****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 COMMENTS FROM PREVIOUS LIST, NOT ADDRESSED:
  
 1. OK
  
 2. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED FOR
 ROOF PANELS, FAC9N-3.
  
 3. SEE FBC RESIDENTIAL TABLE 302.1 FOR SEPARATION
 REQUIREMENTS. PROVIDE FIRE RESISTANCE INFORMATION AS
 REQUIRED BY THE TABLE.
  
 2ND REVIEW, THE SITE PLAN PROVIDED SHOWS ENCROACHMENT
 OVER THE PROPERTY LINE. PROVIDE A SITE PLAN WHICH SHOWS
 PROPOSED CONSTRUCTION (AS PLAN SHOWS REMOVAL OF PORTION
 OF IMPROVEMENT WHICH ENCROACHES THE PROPERTY LINE).
  
 SECTION A-A SHOWS A PROJECTION AND COLUMNS, AND SITE
 PLAN SHOWS A SHED, WHICH ARE LESS THAN 3' FROM THE
 PROPERTY LINE, SEE FBC RESIDENTIAL TABLE R302.1, FIRE
 RESISTANCE REQUIRED.
  
 4. VALUE IS TO INCLUDE LABOR AND MATERIALS, FBC 108.3.
  
 NEW COMMENT:
  
 5. THE SURVEY SHOWS A SHED; NO INFORMATION PROVIDED.
 PROVIDE STRUCTURAL INFORMATION, FBC R 301.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-07-12 Cont ID  
Sent By shill Date 2012-07-12 Time 09:18 Rev Time 0.00
Received By shill Date 2012-07-12 Time 09:18 Sent To  
Notes
2012-07-12 10:19:48****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. THE STRUCTURAL PLAN SUBMITTED IS EXTREMELY
 CONFUSING. A PLAN PREPARED BY GUS TARNOWSKI, PE WAS
 SIGNED AND SEALED BY RIZA ALTAN, PE WITH THE LANGUAGE
 "FOR REFERENCE ONLY." WHO IS TAKING RESPONSIBILITY FOR
 THE DESIGN OF THIS STRUCTURE? IF RIZA ALTAN IS TAKING
 OVER THE WORK OF TARNOWSKI, HAS MR. TARNOWSKI BEEN
 ADVISED AS REQUIRED BY FAC 61G15-27.001? IN THE CASE OF
 A SUCCESSOR ENGINEER REUSING ANOTHER ENGINEER'S PLAN,
 THE OTHER ENGINEER'S TITLE BLOCK SHOULD BE REMOVED AND
 THE SUCCESSOR ENGINEER'S TITLE BLOCK INCLUDED. OR, IS
 MR. RIZA AN EMPLOYEE OF TARNOWSKI ENGINEERING, AND
 AUTHORIZED TO USE THAT TITLE BLOCK? THE TITLE BLOCK
 SHOULD ALSO INCLUDE THE PRINTED NAME AND LICENSE NUMBER
 OF THE INDIVIDUAL SEALING THE PLAN. THE SEAL SHOULD
 INCLUDE A DATE.
  
 A STRUCTURAL PLAN TO SHOW HOW THIS IMPROVEMENT COMPLIES
 WITH FBC RESIDENTIAL 301.1, WIND LOADS, IS REQUIRED.
  
 2. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED FOR
 ROOF PANELS, FAC9N-3.
  
 3. SEE FBC RESIDENTIAL TABLE 302.1 FOR SEPARATION
 REQUIREMENTS. PROVIDE FIRE RESISTANCE INFORMATION AS
 REQUIRED BY THE TABLE.
  
 4. VALUE IS TO INCLUDE LABOR AND MATERIALS, FBC 108.3.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2012-11-14 Cont ID  
Sent By shill Date 2012-11-14 Time 16:39 Rev Time 0.00
Received By shill Date 2012-10-24 Time 17:51 Sent To  
Notes
2012-10-24 17:52:02IN ZONING BOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-10-15 Cont ID  
Sent By shill Date 2012-10-15 Time 16:48 Rev Time 0.00
Received By shill Date 2012-09-28 Time 11:05 Sent To  
Notes
2012-09-28 11:05:59INCOMING SENT TO ZONING BOX. JW

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-07-12 Cont ID  
Sent By shill Date 2012-07-12 Time 10:19 Rev Time 0.00
Received By shill Date 2012-06-08 Time 11:09 Sent To  
Notes
2012-06-08 11:09:52TO ZONING

Review Stop Z ZONING
Rev No 3 Status P Date   Cont ID  
Sent By   Date 2012-11-01 Time   Rev Time 0.00
Received By   Date 2012-10-25 Time   Sent To  
Notes
2012-11-01 13:04:27GAVE TO S.H. - MD

Review Stop Z ZONING
Rev No 2 Status F Date 2012-10-12 Cont ID  
Sent By lfranco Date 2012-10-12 Time 15:17 Rev Time 0.00
Received By lfranco Date 2012-09-28 Time   Sent To  
Notes
2012-10-12 15:26:19PERMIT ROUTED TO LF ON 10/3/12 BY MD
  
 PLANNING : **** FAILED ****
  
  
 1. RESPOND TO COMMENTS IN WRITING.
  
 2. PURSUANT TO THE ZONING CODE, SECTION 94-305(5), AN
 AWNING SHALL NOT PROJECT MORE THAN FOUR (4) FEET INTO
 ANY SETBACK OR BE SUPPORTED BY ANY MEANS OTHER THAN
 ATTACHMENT TO THE BUILDING. THE MINIMUM SIDE SETBACK IS
 FIVE (5) FEET FOR THE BUILDING, THEREFORE, THE AWNING
 CAN ENCROACH UP TO ONE (1) FOOT AWAY FROM THE PROPERTY
 LINE, HOWEVER, THE AWNING IS SUPPORTED BY COLUMNS,
 THEREFORE, IT CANNOT ENCROACH AS PROPOSED ON THE
 SURVEY.
  
 PURSUANT TO SECTION 94-305(2), STRUCTURAL INTRUSIONS -
 THE COLUMNS (POSTS) SHALL NOT EXTEND NO FURTHER THAN
 THREE (3) FEET INTO ANY SETBACK.
  
 RESUBMITTAL: THE SURVEY SHOWS THAT THE SHED IS
 ENCROACHING ON THE PROPERTY LINE. IT NEEDS TO BE
 REMOVED. THE COVERED AREA, AWNING, IS ALSO ENCROACHING
 ON THE PROPERTY LINE. THE POSTS ARE OVER THE PROPERTY
 LINE OR IMMEDIATELY ADJACENT TO THE PROPERTY LINE. THE
 POSTS AS NOTED ON THE COMMENT ABOVE SHALL NOT EXTEND NO
 FURTHER THAN THREE (3) FEET INTO ANY SETBACK. STAFF HAS
 PREVIOUSLY MET WITH CONTRACTOR (STUART LEDIS) TO
 EXPLAIN THE ISSUE WITH THE LOCATION OF THE PROPERTY
 BASED ON THE SURVEY. THE CITY RECOGNIZES THE SURVEY AS
 A LEGAL INSTRUMENT THAT DEPICTS THE PROPERTY LINES AND
 HAS BEEN REVIEWED BY THE VINCE NOEL THE CITY SURVEYOR
 WHO ALSO AGREES WITH THE LEGAL DESCRIPTION OF THE
 SURVEY.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME.
  
 LINDA MIA FRANCO, AICP
 SENIOR PLANNER
 PLANNING DIVISION
 TEL: (561) 822-1443
 EMAIL: [email protected]
  
 GIVEN TO LF ON 10/3/12 BY MD

Review Stop Z ZONING
Rev No 1 Status F Date 2012-06-15 Cont ID  
Sent By lfranco Date 2012-06-15 Time 16:54 Rev Time 0.00
Received By lfranco Date 2012-06-08 Time 15:33 Sent To  
Notes
2012-06-15 17:28:08PLANNING : **** FAILED ****
  
  
 1. RESPOND TO COMMENTS IN WRITING.
  
 2. PURSUANT TO THE ZONING CODE, SECTION 94-305(5), AN
 AWNING SHALL NOT PROJECT MORE THAN FOUR (4) FEET INTO
 ANY SETBACK OR BE SUPPORTED BY ANY MEANS OTHER THAN
 ATTACHMENT TO THE BUILDING. THE MINIMUM SIDE SETBACK IS
 FIVE (5) FEET FOR THE BUILDING, THEREFORE, THE AWNING
 CAN ENCROACH UP TO ONE (1) FOOT AWAY FROM THE PROPERTY
 LINE, HOWEVER, THE AWNING IS SUPPORTED BY COLUMNS,
 THEREFORE, IT CANNOT ENCROACH AS PROPOSED ON THE
 SURVEY.
  
 PURSUANT TO SECTION 94-305(2), STRUCTURAL INTRUSIONS -
 THE COLUMNS SHALL NOT EXTEND NO FURTHER THAN THREE (3)
 FEET INTO ANY SETBACK.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME.
  
 LINDA MIA FRANCO, AICP
 SENIOR PLANNER
 PLANNING DIVISION
 TEL: (561) 822-1443
 EMAIL: [email protected]
  
2012-06-08 15:34:07GIVEN TO LF