Plan Review Details - Permit 12060141
Plan Review Stops For Permit 12060141 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2012-06-19 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-06-19 |
Time |
08:09 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-06-19 |
Time |
08:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2012-06-19 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-06-19 |
Time |
08:08 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-06-19 |
Time |
08:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2012-06-19 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-06-19 |
Time |
08:03 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-06-19 |
Time |
08:03 |
Sent To |
|
|
Notes |
2012-06-19 08:09:49 | SEPARATE APPLICATION, PLANS AND REVIEW IS REQUIRED FOR | | A GAS PERMIT. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2012-06-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-06-25 |
Time |
16:54 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-06-22 |
Time |
14:06 |
Sent To |
|
|
Notes |
2012-06-25 14:07:13 | SENT TO R MCDOUGAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2012-06-19 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-06-19 |
Time |
09:09 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-06-06 |
Time |
14:25 |
Sent To |
|
|
Notes |
2012-06-07 14:25:47 | SENT TO ZONING SHELF FOR REVIEW. JG. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2012-06-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-06-25 |
Time |
16:54 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-06-25 |
Time |
16:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2012-06-19 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-06-19 |
Time |
09:09 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-06-19 |
Time |
08:10 |
Sent To |
|
|
Notes |
2012-06-19 09:26:49 | 2010 FBC | | | | DENIED BY PLUMBING | | | | 1) ACCORDING TO THE MANUFACTURER'S PUMP CURVE FOR THE | | INTELLIFLO VS 3050, THE MAXIMUM FLOW RATE IS 145 GPM AT | | 50 TDH. A 3" SUCTION LINE IS REQUIRED TO ACHIEVE THE 8 | | FEET PER SECOND MAXIMUM VELOCITY ALLOWED FOR SUCTION | | PIPING BY FBC R4101.6.3. ANSI/APSP 7-06 SECTION 4.4 | | REQUIRES THE MAXIMUM SYSTEM FLOW RATE FOR CALCULATIONS. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2012-06-13 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2012-06-13 |
Time |
13:48 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2012-06-08 |
Time |
15:32 |
Sent To |
B |
|
Notes |
|
|
|