Plan Review Stops For Permit 12050724 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2012-07-25 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-07-25 |
Time |
11:19 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-07-25 |
Time |
10:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2012-07-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-07-14 |
Time |
10:55 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-07-14 |
Time |
10:55 |
Sent To |
|
|
Notes |
2012-07-14 11:00:11 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | 1. 3RD REVIEW, PGT COVER SHEETS HAVE BEEN PROVIDED. IT | | APPEARS THAT NOT ALL OF THE KOLBE PRODUCTS HAVE CURRENT | | APPROVAL. ARE THE PRODUCTS WITHOUT APPROVAL TO BE | | REPLACED BY PGT PRODUCTS? ONLY PGT COVER SHEETS | | PROVIDED, NO EVALUATION REPORTS/INSTALLATION | | INSTRUCTIONS. THE PLASTI-PRO DOOR REFERS TO FL 12061.1, | | THIS IS NOT A CURRENT 2010 APPROVAL. ONLY ONE SET | | PROVIDED. | | | | PLEASE ASSEMBLE PACKAGE. PROVIDE TWO COLLATED SETS WITH | | ALL REQUIRED INFORMATION. EACH PRODUCT TO HAVE A | | PRODUCT APPROVAL COVER SHEET (WHICH SHOWS CURRENT | | NUMBER AND STATUS). PRODUCTS NO LONGER PROPOSED SHOULD | | BE MARKED "VOID." | | | | SEE FAC9N-3, FBC 301, PRODUCT APPROVALS REQUIRED TO | | SHOW RESISTANCE TO WIND LOADS AND EVIDENCE OF IMPACT | | PROTECTION. | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2012-06-21 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-06-21 |
Time |
14:09 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-06-21 |
Time |
14:09 |
Sent To |
|
|
Notes |
2012-06-21 14:13:49 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | 1. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED. | | FOR THE EVALUATION REPORTS SUBMITTED, PROVIDE THE | | FLORIDA STATE PRODUCT APPROVAL COVER SHEET, | | WWW.FLORIDABUILDING.ORG. THIS IS REQUIRED IN ORDER TO | | CONFIRM THAT THE PRODUCT HAS A VALID APPROVAL, FAC9N-3. | | | | 2ND REVIEW, NOT ADDRESSED. ULTRA STERLING IMPACT DOUBLE | | HUNG WINDOW, ULTRA IMPACT CASEMENT, ULTRA TRADITIONAL | | HORIZONTAL SLIDER, GLAZED FIBERGLASS DOOR, NEED FLORIDA | | STATE OR LOCAL PRODUCT APPROVAL. ONLY TEST REPORTS | | | | 2. IN ORDER TO EXPEDITE THE INSPECTION PROCESS, AND DUE | | TO THE NUMBER OF DIFFERENT PRODUCTS BEING INSTALLED, IT | | IS SUGGESTED THAT THE SPECIFIC ANCHOR METHOD/APPLICABLE | | DETAILS FOR INSPECTION FOR EACH PRODUCT BE | | TABBED/HIGHLIGHTED. ***THIS DOES NOT NEED TO BE DONE | | PRIOR TO PERMIT ISSUANCE, BUT IS SUGGESTED TO BE DONE | | PRIOR TO FIRST INSPECTION*** | | | | NEW COMMENT: | | | | 3. IF YOU DO NOT UNDERSTAND THE COMMENTS, PLEASE | | CONTACT ME. THE RESUBMITTAL INCLUDED PHOTOS OF ALL OF | | THE WINDOWS. THIS IS NOT REQUIRED AND WAS NOT | | REQUESTED. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2012-06-06 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-06-06 |
Time |
07:59 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-06-06 |
Time |
07:59 |
Sent To |
|
|
Notes |
2012-06-06 08:03:17 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | 1. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED. | | FOR THE EVALUATION REPORTS SUBMITTED, PROVIDE THE | | FLORIDA STATE PRODUCT APPROVAL COVER SHEET, | | WWW.FLORIDABUILDING.ORG. THIS IS REQUIRED IN ORDER TO | | CONFIRM THAT THE PRODUCT HAS A VALID APPROVAL, FAC9N-3. | | | | 2. IN ORDER TO EXPEDITE THE INSPECTION PROCESS, AND DUE | | TO THE NUMBER OF DIFFERENT PRODUCTS BEING INSTALLED, IT | | IS SUGGESTED THAT THE SPECIFIC ANCHOR METHOD/APPLICABLE | | DETAILS FOR INSPECTION FOR EACH PRODUCT BE | | TABBED/HIGHLIGHTED. ***THIS DOES NOT NEED TO BE DONE | | PRIOR TO PERMIT ISSUANCE, BUT IS SUGGESTED TO BE DONE | | PRIOR TO FIRST INSPECTION*** | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2012-07-25 |
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
2012-07-25 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2012-05-24 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2012-05-24 |
Time |
10:04 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2012-05-24 |
Time |
09:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-07-25 |
Time |
11:19 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-07-19 |
Time |
15:29 |
Sent To |
|
|
Notes |
2012-07-25 11:34:41 | 7/25 TO ZONING | | | 2012-07-20 15:30:14 | SENT TO SAMANTHA'S DESK FOR REVIEW. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2012-07-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-07-14 |
Time |
11:00 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-07-03 |
Time |
17:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2012-06-21 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-06-21 |
Time |
14:13 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-06-15 |
Time |
17:42 |
Sent To |
|
|
Notes |
2012-06-15 17:42:58 | GAVE TO SAMANTHA |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2012-06-06 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-06-06 |
Time |
08:23 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-05-24 |
Time |
10:14 |
Sent To |
|
|
Notes |
2012-05-29 10:14:40 | INCOMING SENT TO MISC BOX # 1. JW |
|
|