Plan Review Details - Permit 12050220
Plan Review Stops For Permit 12050220
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2012-07-09 Cont ID  
Sent By jwitmer Date 2012-07-09 Time 11:16 Rev Time 0.00
Received By jwitmer Date 2012-07-09 Time 11:16 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2012-05-09 Cont ID  
Sent By rlecky Date 2012-05-09 Time 11:23 Rev Time 0.00
Received By rlecky Date 2012-05-09 Time 11:23 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2012-07-14 Cont ID  
Sent By wjolin Date 2012-07-14 Time 18:22 Rev Time 0.00
Received By wjolin Date 2012-07-14 Time 18:16 Sent To IMPACT
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2012-07-09 Cont ID  
Sent By ddaniels Date 2012-07-09 Time 12:32 Rev Time 0.00
Received By ddaniels Date 2012-07-09 Time 12:32 Sent To  
Notes
2012-07-09 12:53:0607/09/2012 PLANS REVIEWED BY FIRE ***DENIED***
  
 1. PROVIDE EMERGENCY LIGHTING FOR PATH OF EXIT IN ROOM
 LABELED ACCOUNTING ON SHEET A-3.
 2. ADD A FIRE ALARM PULL STATION AT EXIT DOOR IN ROOM
 LABELED ACCOUNTING ON SHEET A-2
  
 DERRICK DANIELS, BATTALION CHIEF / FIRE MARSHAL
 OFFICE OF THE FIRE MARSHAL
 561 804-4709

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2012-05-29 Cont ID  
Sent By wjolin Date 2012-05-29 Time 10:36 Rev Time 0.00
Received By wjolin Date 2012-05-29 Time 10:35 Sent To  
Notes
2012-05-29 10:35:572465 MERCER AVENUE - SUITE #106 & #107
 PERMIT #12050220
 (SEE ALSO PERMIT #12050218 FOR SUITE #105)
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 THE 2009 EDITION OF BOTH NFPA 1 AND NFPA 101 WITH
 FLORIDA AMENDMENTS SHOULD BE REFERENCED IN THE CODE
 LIST.
  
 ALL CONSTRUCTION AND DEMOLITION WORK SHALL CONFORM TO
 THE REQUIREMENTS OF NFPA 241. TRASH AND CONSTRUCTION
 DEBRIS SHALL BE REMOVED FROM THE SITE DAILY. ALL
 DEMOLITION OR CONSTRUCTION AREAS SHALL HAVE "NO
 SMOKING" SIGNS POSTED.
  
 FIRE PROTECTION SYSTEMS SHALL REMAIN ACTIVE DURING
 DEMOLITION AND RENOVATION ACTIVITIES. IN THE EVENT A
 FIRE PROTECTION SYSTEM IS OUT OF SERVICE FOR MORE THAN
 4-HOURS IN A 24-HOUR PERIOD, THE BUILDING SHALL BE
 PLACED UNDER A FIRE WATCH. ALL FIRE WATCH REQUESTS MUST
 BE SUBMITTED IN WRITING AND APPROVED BY THE OFFICE OF
 THE FIRE MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY.
  
 PROVIDE AN EXTERIOR KEY SAFE TO ALLOW EMERGENCY
 RESPONDERS NON-FORCIBLE ENTRY INTO THE BUILDING DURING
 NON-BUSINESS HOURS. A KEY SAFE CAN BE ORDERED FROM
 WWW.KNOXBOX.COM.
  
 PROVIDE TACTILE SIGNAGE AT ALL REQUIRED EXIT DOORS WITH
 EXIT SIGNS.
  
 PLANS DO NOT INDICATE THE SCOPE OF WORK FOR THE FIRE
 SPRINKLER SYSTEM. ANY RESIDENTIAL TYPE SPRINKLERS WOULD
 NEED TO BE REPLACED WITH COMMERCIAL STYLE SPRINKLERS.
  
 SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE
 MODIFICATION OF THE FIRE SPRINKLER SYSTEM AND FIRE
 ALARM SYSTEM.
  
 PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS
 SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE
 TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL
 DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET.
  
 ALL EXTERIOR DOORS NOT FUNCTIONING AS EXITS SHALL BE
 PERMANENTLY MARKED AND CLEARLY INDICATED AS, "NOT AN
 EXIT."
  
 SHEET A-2: PROVIDE FIRE ALARM NOTIFICATION APPLIANCE IN
 CONFERENCE ROOM #2 AND IN HALLWAY NEAR BREAK ROOM/COPY
 ROOM.
  
 SHEET A-3: PROVIDE EMERGENCY LIGHTING FOR EXIT PATH IN
 MTC ROOM.
  
 WESLEY JOLIN
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-07-16 Cont ID  
Sent By lmartine Date 2012-07-14 Time 16:33 Rev Time 0.00
Received By lmartine Date 2012-07-13 Time 12:56 Sent To  
Notes
2012-07-13 12:56:08TO WJ

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-07-11 Cont ID  
Sent By hmoser Date 2012-07-09 Time 09:08 Rev Time 0.00
Received By hmoser Date 2012-07-02 Time 09:08 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2012-07-11 Cont ID  
Sent By hmoser Date 2012-07-11 Time 09:05 Rev Time 0.00
Received By hmoser Date 2012-07-11 Time 08:17 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2012-05-18 Cont ID  
Sent By hmoser Date 2012-05-18 Time 14:19 Rev Time 0.00
Received By hmoser Date 2012-05-18 Time 14:19 Sent To  
Notes
2012-05-18 14:24:34PLANS DENIED
 1 PROVIDE FRESH AIR CALCULATIONS PER TABLE 403.3 FBC
 (M) 2010.
 2 REFER TO SECTION 503.2.1 CALCULATION OF HEATING AND
 COOLING LOADS
 2010 FLORIDA ENERGY CODE.
 PLAN REVIEW BY HAROLD MOSER
 561-805-6732
 [email protected]

Review Stop P PLUMBING
Rev No 2 Status N Date 2012-07-12 Cont ID  
Sent By lwagner Date 2012-07-12 Time 15:23 Rev Time 0.00
Received By lwagner Date 2012-07-12 Time 15:23 Sent To  
Notes
2012-07-12 15:23:57NO PLUMBING DRAWINGS
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2012-05-11 Cont ID  
Sent By lwagner Date 2012-05-11 Time 14:50 Rev Time 0.00
Received By lwagner Date 2012-05-11 Time 14:50 Sent To  
Notes
2012-05-11 14:51:15FBC PLUMBING 2010
 FBC ACCESSIBILITY 2010
 REVIEW #1
 DENIED:
  
 1. SHEET A-1 SHOWS RESTROOMS 5'-7" WIDE
 FBC ACCESSIBILITY 2010 - 604.3.1 AND 604.3.2 REQUIRE A
 5' CLEAR SPACE FOR THE WATER CLOSET WITH NO OTHER
 FIXTURES WITHIN THAT SPACE.
  
 2. SHEET A-5 SHOWS A SINK ATTACHED TO A WET VENT
 SYSTEM. THE SINK IS REQUIRED TO CONNECT DOWNSTREAM OF
 THE WET VENTED RESTROOM.
 FBC PLUMBING 909.1 HORIZONTAL WET VENT PERMITTED. ANY
 COMBINATION OF FIXTURES WITHIN TWO BATHROOM GROUPS
 LOCATED ON THE SAME FLOOR LEVEL IS PERMITTED TO BE
 VENTED BY A HORIZONTAL WET VENT.....ANY ADDITIONAL
 FIXTURES SHALL DISCHARGE DOWNSTREAM OF THE HORIZONTAL
 WET VENT.
  
 REVIEW BY
 LARRY WAGNER
 CHIEF PLUMBING INSPECTOR
 PHONE # 805-6692
 EMAIL [email protected]
 FAX # 805-6676
  
  
  
  
  

Review Stop Z ZONING
Rev No 1 Status P Date 2012-05-15 Cont ID  
Sent By jroach Date 2012-05-15 Time 13:25 Rev Time 0.00
Received By jroach Date 2012-05-15 Time 13:25 Sent To  
Notes
***NONE***