Plan Review Details - Permit 12050020
Plan Review Stops For Permit 12050020
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2012-08-03 Cont ID  
Sent By shill Date 2012-08-03 Time 19:01 Rev Time 0.00
Received By shill Date 2012-08-03 Time 19:01 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-05-15 Cont ID  
Sent By shill Date 2012-05-15 Time 10:55 Rev Time 0.00
Received By shill Date 2012-05-15 Time 10:55 Sent To  
Notes
2012-05-15 11:09:23****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2010
 FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL
  
 1. ON SHEET 1, PLEASE REVISE THE FOLLOWING:
  
 GOVERNING CODE
 WIND SPEED
 EXPOSURE CLASSIFICATION (APPEARS TO BE D)
 ASCE 7 REFERENCE (FBC CHAPTER 35)
  
 SEE FBC 1603.1.4 FOR INFORMATION REQUIRED ON THE PLAN.
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2012-08-03 Cont ID  
Sent By shill Date 2012-08-03 Time 19:01 Rev Time 0.00
Received By shill Date 2012-08-03 Time 19:01 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2012-05-07 Cont ID  
Sent By rlecky Date 2012-05-07 Time 16:15 Rev Time 0.00
Received By rlecky Date 2012-05-07 Time 16:12 Sent To B
Notes
2012-05-07 16:16:15REQUIRES AN ELECTRICAL PERMIT AND PLANS.
  
 ROBERT LECKY, CBO
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6718
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2012-08-03 Cont ID  
Sent By shill Date 2012-08-03 Time 19:01 Rev Time 0.00
Received By shill Date 2012-07-27 Time 12:22 Sent To  
Notes
2012-07-30 12:22:24IN ZONING BOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-08-03 Cont ID  
Sent By shill Date 2012-08-03 Time 19:01 Rev Time 0.00
Received By shill Date 2012-07-26 Time 09:54 Sent To  
Notes
2012-08-03 14:26:488/3 ON SH DESK
2012-07-27 09:54:57SENT TO ZONING SHELF FOR JOHN'S REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-05-15 Cont ID  
Sent By shill Date 2012-05-15 Time 11:09 Rev Time 0.00
Received By shill Date 2012-05-01 Time 16:06 Sent To  
Notes
2012-05-01 16:06:13TO ZONING
  

Review Stop Z ZONING
Rev No 2 Status P Date 2012-08-03 Cont ID  
Sent By jroach Date 2012-08-03 Time 10:02 Rev Time 0.00
Received By jroach Date 2012-08-03 Time 10:02 Sent To E
Notes
2012-08-03 10:03:07PROVISO
  
 1. PRIOR TO ISSUANCE OF A CERTIFICATE OF COMPLETION,
 ALL MOORING SLIPS SHALL BE PROVIDED WITH APPROPRIATE
 CONNECTIONS FOR POTABLE WATER AND ELECTRICAL SERVICE.
 2. ALL DECKING SHALL BE CONSTRUCTED OF A GRATED
 MATERIAL WITH 43 PERCENT OPEN SPACE.
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER,
 AT (561) 822-1435.
  

Review Stop Z ZONING
Rev No 1 Status F Date 2012-05-07 Cont ID  
Sent By jroach Date 2012-05-07 Time 14:38 Rev Time 0.00
Received By jroach Date 2012-05-03 Time 10:01 Sent To E
Notes
2012-05-07 14:39:05ZONING PLAN REVIEW
 ___________________________________________
  
 DATE OF REVIEW: 05.07.2012
 PERMIT NO.: 12050020
 ADDRESS: 5901 SOUTH FLAGLER DRIVE
 CONTRACTOR/CONTACT: CHRIS BRYANT
 TELEPHONE NO.: 421.2321
 SCOPE OF REVIEW: INSTALL FINGER PIER, BOATLIFT, AND 4
 MOORING PILINGS.
 ___________________________________________
  
 REVIEW STATUS: FAILED
 ___________________________________________
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1. PRIOR TO THE ISSUANCE OF A BUILDING PERMIT, A CLASS
 A SPECIAL USE PERMIT MUST BE APPROVED BY THE CITY
 COMMISSION. AN APPLICATION FOR SUCH HAS ALREADY BEEN
 SUBMITTED; HOWEVER, SUCH PROCESS SHALL BE COMPLETED
 PRIOR TO THE ISSUANCE OF THE BUILDING PERMIT.
  
 2. PLEASE INCLUDE WITH THE BUILDING PERMIT APPLICATION
 THE LETTER PROVIDED FROM THE PROPERTY OWNER'S ATTORNEY
 INDICATING PROOF OF RIPARIAN RIGHTS.
  
 3. PLEASE NOTE THAT THE APPROVAL FROM THE US ARMY CORPS
 OF ENGINEERS HAS EXPIRED, AS OF MAY 1, 2012.
  
 4. PLEASE PROVIDE A COPY OF A SEAGRASS STUDY TO SHOW
 THAT NO MARINE GRASSES, ETHNIC COMMUNITIES, OR
 IMPORTANT ESTUARINE OR ECOLOGICAL FEATURES ARE BEING
 AFFECTED BY THE PROPOSED DOCK CONSTRUCTION.
  
 5. ALL MOORING SLIPS SHALL BE PROVIDED WITH APPROPRIATE
 CONNECTIONS FOR POTABLE WATER AND ELECTRICAL SERVICE.
 IT IS ASSUMED THAT ELECTRICAL SERVICE IS BEING PROVIDED
 AS THERE IS A PROPOSED BOAT LIFT, BUT PLANS DO NOT
 REFERENCE ANY POTABLE WATER CONNECTION. PLEASE
 CLARIFY?IS A WAIVER FROM THIS PROVISION BEING REQUESTED
 AS PART OF THE CLASS A SPECIAL USE PERMIT?
  
 6. THE CENTERLINE OF THE DOCK SHALL BE CONSTRUCTED
 PERPENDICULAR TO THE SEAWALL?A WAIVER FROM THIS
 PROVISION WILL BE REQUIRED AS PART OF THE CLASS A
 SPECIAL USE PERMIT.
  
 7. PLEASE NOTE THE DISTANCE FROM THE END OF THE DOCK TO
 THE NAVIGABLE CHANNEL.
 ___________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ___________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN ROACH, SENIOR PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3366
 WEST PALM BEACH, FLORIDA 33402
  
 PHONE: 561.822.1435
 FAX: 561.822.1460
  
 EMAIL: [email protected]
  