Plan Review Stops For Permit 12040671 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2012-04-26 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2012-04-26 |
Time |
12:45 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2012-04-26 |
Time |
12:45 |
Sent To |
|
|
Notes |
2012-04-26 12:45:40 | BUILDING PROVISO: | | 2010 FBC-B 1507.2.8 UNDERLAYMENT APPLICATION. FOR ROOF | | SLOPES FROM TWO UNITS VERTICAL IN 12 UNITS HORIZONTAL | | (17-PERCENT SLOPE) AND UP TO FOUR UNITS VERTICAL IN 12 | | UNITS HORIZONTAL (33-PERCENT SLOPE), UNDERLAYMENT SHALL | | BE TWO LAYERS APPLIED IN THE FOLLOWING MANNER. APPLY A | | MINIMUM 19-INCH-WIDE (483 MM) STRIP OF UNDERLAYMENT | | FELT PARALLEL WITH AND STARTING AT THE EAVES, FASTENED | | SUFFICIENTLY TO HOLD IN PLACE. STARTING AT THE EAVE, | | APPLY 36-INCH-WIDE (914 MM) SHEETS OF UNDERLAYMENT | | OVERLAPPING SUCCESSIVE SHEETS 19 INCHES (483 MM), BY | | FASTENED SUFFICIENTLY TO HOLD IN PLACE. DISTORTIONS IN | | THE UNDERLAYMENT SHALL NOT INTERFERE WITH THE ABILITY | | OF THE SHINGLES TO SEAL. FOR ROOF SLOPES OF FOUR UNITS | | VERTICAL IN 12 UNITS HORIZONTAL (33-PERCENT SLOPE) OR | | GREATER, UNDERLAYMENT SHALL BE ONE LAYER APPLIED IN THE | | FOLLOWING MANNER. UNDERLAYMENT SHALL BE APPLIED SHINGLE | | FASHION, PARALLEL TO AND STARTING FROM THE EAVE AND | | LAPPED 2 INCHES (51 MM), FASTENED SUFFICIENTLY TO HOLD | | IN PLACE. DISTORTIONS IN THE UNDERLAYMENT SHALL NOT | | INTERFERE WITH THE ABILITY OF THE SHINGLES TO SEAL. | | |
|
|
|