Plan Review Stops For Permit 12040588 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2012-10-10 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2012-10-10 |
Time |
13:41 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2012-10-10 |
Time |
13:40 |
Sent To |
|
|
Notes |
2012-10-10 14:01:38 | BUILDING PLAN REVIEW | | PERMIT: 12040588 | | ADD:2700 BROADWAY | | CONT: PKS CONSTRUCTION | | TEL: (561)704-2394 | | | | 2010 FLORIDA BUILDING CODE W | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | 4TH REVIEW | | OCT .10/2012 | | ENGINEER JOHN HOLT PE # 15252 | | | | | | BUILDING APPROVED WITH EXCEPTION! | | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO | | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO | | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE | | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE | | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. | | | | A SEPERATE ROOFING PERMIT IS REQUIRED. PRODUCT | | APPROVALS WERE GIVEN BACK TO THE CGC TO BE SUBMITTED BY | | ROOFING CONTRACTOR. | | PRODUCT APPROVALS WERE SUBMITTED: | | 1) SANTAFE TILE, MISSION BARREL ROOFING TILE NOA | | 07-0626.04. | | RUBBER STAMP REVIEWED AND APPROVED BY JOHN HOLT PE BUT | | NO SIGNATURE | | TYPE OF ATTACHMENT FOR ROOF TILE NOT IDENTIFIED | | | | 2) POLYGLASS SELF-ADHERED ROOF SYSTEM OVER WOOD DECK | | NOA 11-0425.07 | | SUB-SYSTEMS NOT IDENTIFIED AS TO WHICH SUB-SYSTEM WOULD | | BE INSTALLED, ALL SUB-SYSTEMS WITH LIMITATION # 7 | | WILL NEED ENHANCED FASTENING RAS 117 SCHEDULE BY EITHER | | AN ENGINEER, ARCHITECT | | | | 3) FLAT DECK BASE SHEET NAILING SCHEDULE SUBMITTED NO | | DESIGN PROFESSIONAL SIGNATURE NOR SEAL AS PER NOA | | REQUIREMENT LIMITATION # 7. | | | | 4) 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | SHOP DRAWINGS ETC.. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CONSTRUCTION SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2012-09-14 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2012-09-14 |
Time |
16:15 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2012-09-14 |
Time |
15:46 |
Sent To |
|
|
Notes |
2012-09-14 16:12:47 | BUILDING PLAN REVIEW | | PERMIT: 12040588 | | ADD:2700 BROADWAY | | CONT: PKS CONSTRUCTION | | TEL: (561)704-2394 | | | | 2010 FLORIDA BUILDING CODE W | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | 3RD REVIEW | | SEPT. 14/2012 | | ENGINEER JOHN HOLT PE # 15252 | | | | | | 1ST REVIEW | | ACTION: DENIED | | | | 1) SHEET A-1: | | 1A) SHEET A-1 & A-2 SIGNED AND SEALED DATED 8/29/12, | | PLANS ARE DESIGNED UNDER THE 2007 FBC-B. MARCH 15/ 2012 | | IS THE ADOPTION DATE STATEWIDE FOR THE 2010 FBC-B, | | PLANS SUBMITTED ON THAT DATE AND LATER FOR FIRST REVIEW | | ARE TO BE DESIGNED TO THE 2010 FBC. SINCE THIS IS AN | | ADDITION THE PLANS WILL ALSO BE REVIEWED TO THE 2010 | | EXISTING BUILDING CODE CHAPTER 10 FOR ADDITIONS AND | | CHAPTER 11 FOR HISTORIC BUILDINGS. | | | | | | 1B) 2010 EXIST BUILDING CODE 1002.2 PLEASE PROVIDE CODE | | ANALYSIS FOR BUILDING, MINIMUM BUILDING TYPE, SQUARE | | FOOTAGE OF EXISTING BUILDING, SPRINKLERED OR NOT AND | | TYPE OF OCCUPANCY FOR AREA LIMITATIONS. 106.3.5.1.1* | | MINIMUM COMMERCIAL PLAN REVIEW CRITERIA. | | THE PROPERTY APPRAISERS OFFICE AND CITY LIST THIS | | BUILDING AS A RESTROOM (I-1). PLANS INDICATE THIS AS A | | A-2 OCCUPANCY? | | SHEET A1 ALSO INDICATES THE MINIMUM BLDG TYPE AS A TYPE | | 5 CLASS 1 THIS IS NOT TERMINOLOGY FOUND IN TABLE 503 | | EITHER VA OR VB. | | | | 1C) SHEET A-1 INDICATES THE PLANS ARE DESIGNED TO THE | | 2010 FBC FOR WIND DESIGN BUT STILL REFERENECES ASCE | | 7-05 AND A IMPORTANCE FACTOR OF 1.15 WHAT IS REQUIRING | | THE IMPORTANCE FACTOR OF 1.15, THE 2010 WIND TABLE HAVE | | THIS DESIGNED INTO WHICH WIND SPEED MAP THAT IS USED, | | THE 170 MPH WIND ZONE MAP WILL BE A BUILDING CATEGORY | | OF II, THE THE EXPOSURE ZONE AND HEIGHT FACTOR ARE NOT | | PROVIDED WITHIN THE WIND DESIGN CRITERIA 2010 FBC-B T | | 1609.7.(2). PLEASE SHOW PRESSURES IN VULT. | | OLD COMMENT: WIND DESIGN CRITERIA IS FOR THE 2007 FBC | | NOT THE 2010 FBC-B PLEASE REVIEW 1609.1.1. | | | | 2-3) COMPLIED. | | | | NEW COMMENTS: | | | | 4) PRODUCT APPROVALS SUBMITTED POLYGLASS NOA | | 11-0425.07, & GAF MODIFIED NOA 11-0425.07 ARE STAMPED | | REVIEWED BY LUIS LOPEZ NOT REVIEWED BY PE JOHN HOLT, | | NEITHER HAS THE PRODUCT APPROVAL SANTAFE TILE, MISSION | | BARREL ROOFING TILE NOA 07-0626.04. | | | | 2010 FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | SHOP DRAWINGS ETC.. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CONSTRUCTION SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2012-07-24 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2012-07-24 |
Time |
11:32 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2012-07-24 |
Time |
11:32 |
Sent To |
|
|
Notes |
2012-07-24 11:34:56 | BUILDING PLAN REVIEW | | PERMIT: 12040588 | | ADD:2700 BROADWAY | | CONT: PKS CONSTRUCTION | | TEL: (561)704-2394 | | | | 2010 FLORIDA BUILDING CODE W | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | 2ND REVIEW | | | | ENGINEER LUIS LOPEZ PE # 59805 VOLUNTARY RELINGUISHMENT | | 4/27/2012. JW | | | | | | 1ST REVIEW | | ACTION: DENIED | | | | 1) SHEET A-1: | | 1A) SHEET A-1 & A-2 SIGNED AND SEALED DATED 4/19/2012, | | PLANS ARE DESIGNED UNDER THE 2007 FBC-B. MARCH 15/ 2012 | | IS THE ADOPTION DATE STATEWIDE FOR THE 2010 FBC-B, | | PLANS SUBMITTED ON THAT DATE AND LATER FOR FIRST REVIEW | | ARE TO BE DESIGNED TO THE 2010 FBC. SINCE THIS IS AN | | ADDITION THE PLANS WILL ALSO BE REVIEWED TO THE 2010 | | EXISTING BUILDING CODE CHAPTER 10 FOR ADDITIONS AND | | CHAPTER 11 FOR HISTORIC BUILDINGS. | | | | 1B) 2010 EXIST BUILDING CODE 1002.2 PLEASE PROVIDE CODE | | ANALYSIS FOR BUILDING, MINIMUM BUILDING TYPE, SQUARE | | FOOTAGE OF EXISTING BUILDING, SPRINKLERED OR NOT AND | | TYPE OF OCCUPANCY FOR AREA LIMITATIONS. 106.3.5.1.1* | | MINIMUM COMMERCIAL PLAN REVIEW CRITERIA. | | | | 1C) WIND DESIGN CRITERIA IS FOR THE 2007 FBC NOT THE | | 2010 FBC-B PLEASE REVIEW 1609.1.1. | | | | 2) FRONT PORCH ADDITION; | | 2A) SHEET A2 ROOF FRAMING PLAN FAILS TO IDENTIFY BOTH | | B-1 CARRYING BEAM ATTACHMENTS TO THE EXISTING | | STRUCTURE, PART OF THE MWFRS (MAIN WIND FORCE RESITING | | SYSTEM) PLEASE PROVIDE TYPE OF BUCKET AND ATTACHMENT. | | 106.1.2* ADTIONAL INFORMATION REQUIRED / | | 106.3.5.1.1.(8)*. | | | | 2B) SHEET A1 FRONT PORCH DETAIL INDICATES THE ROOF | | JOIST ANCHORING TO BEAM B1 BUT THIS DETAIL NOR THE | | DETAIL ON A2 PROVIDE THE CANTILVERED ROOF JOIST | | ATTACHMENT TO BEAM B-1 NOR THE COMMON JOIST THEY ATTACH | | TOO? PART OF THE MWFRS, 106.3.5.1.1(8)*. | | | | 2C) THE SAME DETAIL INDICATES THE ATTACHMENT OF LEDGER | | TO THE WALL WITH 1/2" BOLTS @ 4'-0" O.C.? PLANS LACK | | THE TYPE OF ANCHOR TO BE INSTALLED, LENGTH OF ANCHOR, | | IS THIS ANCHOR GOING TO BE INSTALLED INTO A CONCRETE | | BEAM, FILLED MASONRY BLOCK BEAM OR EMPTY CONCRETE BLOCK | | UNITS. | | | | 2D) SHEET A-1 FRONT PORCH DETAIL INDICATES THE ROOFING | | MATERIALS TO BE MODIFIED PEEL AND STICK ROOFING WHERE | | AS THE ACTUAL PRODUCT APPROVAL IS A GAF RUBEROID | | MODIFIED BITUMEN ROOF SYSTEM FOR ROOF DECKS WHICH IS | | CORRECT? IF THE PEEL AND STICK NOTE IS DELETED AND THIS | | APPROVAL WILL BE INSTALLED THEN PLEASE IDENTIFY WHICH | | OF THE SUB-SYSTEMS WILL BE APPLIED, PLEASE NOTE THAT IN | | ROOF ZONES 2 & 3 ENHANCED FASTENING WILL BE REQUIRED | | WHEN LIMITATION NOTE # 7 APPEARS LIMITATION NOTE # 9 | | DOES NOT ALLOW FOR ENHANCED FASTENING. | | | | 3) BACK PORCH ADDITION, ALL OF THE CONDITIONS LISTED | | ABOVE ARE THE SAME CONDITIONS FOR THE BACK PORCH | | ADDITION. | | | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CONSTRUCTION SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2012-05-22 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2012-05-22 |
Time |
10:10 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2012-05-22 |
Time |
09:56 |
Sent To |
|
|
Notes |
2012-05-22 10:59:31 | BUILDING PLAN REVIEW | | PERMIT: 12040588 | | ADD:2700 BROADWAY | | CONT: PKS CONSTRUCTION | | TEL: (561)704-2394 | | | | 2010 FLORIDA BUILDING CODE W | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | 1ST REVIEW | | ACTION: DENIED | | | | 1) SHEET A-1: | | 1A) SHEET A-1 & A-2 SIGNED AND SEALED DATED 4/19/2012, | | PLANS ARE DESIGNED UNDER THE 2007 FBC-B. MARCH 15/ 2012 | | IS THE ADOPTION DATE STATEWIDE FOR THE 2010 FBC-B, | | PLANS SUBMITTED ON THAT DATE AND LATER FOR FIRST REVIEW | | ARE TO BE DESIGNED TO THE 2010 FBC. SINCE THIS IS AN | | ADDITION THE PLANS WILL ALSO BE REVIEWED TO THE 2010 | | EXISTING BUILDING CODE CHAPTER 10 FOR ADDITIONS AND | | CHAPTER 11 FOR HISTORIC BUILDINGS. | | | | 1B) 2010 EXIST BUILDING CODE 1002.2 PLEASE PROVIDE CODE | | ANALYSIS FOR BUILDING, MINIMUM BUILDING TYPE, SQUARE | | FOOTAGE OF EXISTING BUILDING, SPRINKLERED OR NOT AND | | TYPE OF OCCUPANCY FOR AREA LIMITATIONS. 106.3.5.1.1* | | MINIMUM COMMERCIAL PLAN REVIEW CRITERIA. | | | | 1C) WIND DESIGN CRITERIA IS FOR THE 2007 FBC NOT THE | | 2010 FBC-B PLEASE REVIEW 1609.1.1. | | | | 2) FRONT PORCH ADDITION; | | 2A) SHEET A2 ROOF FRAMING PLAN FAILS TO IDENTIFY BOTH | | B-1 CARRYING BEAM ATTACHMENTS TO THE EXISTING | | STRUCTURE, PART OF THE MWFRS (MAIN WIND FORCE RESITING | | SYSTEM) PLEASE PROVIDE TYPE OF BUCKET AND ATTACHMENT. | | 106.1.2* ADTIONAL INFORMATION REQUIRED / | | 106.3.5.1.1.(8)*. | | | | 2B) SHEET A1 FRONT PORCH DETAIL INDICATES THE ROOF | | JOIST ANCHORING TO BEAM B1 BUT THIS DETAIL NOR THE | | DETAIL ON A2 PROVIDE THE CANTILVERED ROOF JOIST | | ATTACHMENT TO BEAM B-1 NOR THE COMMON JOIST THEY ATTACH | | TOO? PART OF THE MWFRS, 106.3.5.1.1(8)*. | | | | 2C) THE SAME DETAIL INDICATES THE ATTACHMENT OF LEDGER | | TO THE WALL WITH 1/2" BOLTS @ 4'-0" O.C.? PLANS LACK | | THE TYPE OF ANCHOR TO BE INSTALLED, LENGTH OF ANCHOR, | | IS THIS ANCHOR GOING TO BE INSTALLED INTO A CONCRETE | | BEAM, FILLED MASONRY BLOCK BEAM OR EMPTY CONCRETE BLOCK | | UNITS. | | | | 2D) SHEET A-1 FRONT PORCH DETAIL INDICATES THE ROOFING | | MATERIALS TO BE MODIFIED PEEL AND STICK ROOFING WHERE | | AS THE ACTUAL PRODUCT APPROVAL IS A GAF RUBEROID | | MODIFIED BITUMEN ROOF SYSTEM FOR ROOF DECKS WHICH IS | | CORRECT? IF THE PEEL AND STICK NOTE IS DELETED AND THIS | | APPROVAL WILL BE INSTALLED THEN PLEASE IDENTIFY WHICH | | OF THE SUB-SYSTEMS WILL BE APPLIED, PLEASE NOTE THAT IN | | ROOF ZONES 2 & 3 ENHANCED FASTENING WILL BE REQUIRED | | WHEN LIMITATION NOTE # 7 APPEARS LIMITATION NOTE # 9 | | DOES NOT ALLOW FOR ENHANCED FASTENING. | | | | 3) BACK PORCH ADDITION, ALL OF THE CONDITIONS LISTED | | ABOVE ARE THE SAME CONDITIONS FOR THE BACK PORCH | | ADDITION. | | | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CONSTRUCTION SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2012-04-30 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2012-04-30 |
Time |
12:52 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2012-04-30 |
Time |
11:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
3 |
Status |
P |
Date |
2012-09-10 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2012-09-10 |
Time |
11:06 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2012-09-10 |
Time |
11:06 |
Sent To |
|
|
Notes |
2012-09-10 11:06:37 | MUST USE 6X6 COLUMN FOR SUPPORT |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
F |
Date |
2012-07-20 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2012-07-20 |
Time |
12:29 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2012-07-20 |
Time |
12:29 |
Sent To |
|
|
Notes |
2012-07-20 12:30:31 | APPLICATION REQUIRES FILING OF A COA (CERTIFICATE OF | | APPROPRIATENESS). ADDTION DOES NOT APPEAR TO BE | | ARCHITECTURALLY COMPATIBLE. SAME CONCERNS AS FROM FIRST | | SUBMITTAL. QUESTIONS CONTACT FRIEDERIKE AT 822-1457. |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
F |
Date |
2012-05-10 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2012-05-10 |
Time |
11:48 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2012-05-10 |
Time |
11:48 |
Sent To |
|
|
Notes |
2012-05-10 11:51:44 | REQUIRES A CERTIFICATE OF APPROPRIATENESS | | (COA)....OVERHANGS NOT ARCHITECTURALLY COMPATIBLE. | | SLOPED WITH BARREL TILE. QUESTIONS, CONTACT FRIEDERIKE | | MITTNER 822-1457. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2012-10-10 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2012-10-10 |
Time |
14:22 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2012-10-09 |
Time |
10:59 |
Sent To |
|
|
Notes |
2012-10-10 11:00:11 | SENT TO JIM'S DESK FOR REVIEW. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2012-09-14 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2012-09-14 |
Time |
16:16 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2012-09-10 |
Time |
16:49 |
Sent To |
|
|
Notes |
2012-09-13 16:50:01 | SENT TO JIM'S DESK FOR REVIEW. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2012-09-13 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2012-07-24 |
Time |
16:48 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2012-07-03 |
Time |
08:50 |
Sent To |
|
|
Notes |
2012-09-13 16:48:54 | LAST REVIEW WAS DONE ON 7/24/12. JG. | 2012-07-03 08:49:49 | INCOMING SENT TO ZONING/ HISTORIC BOX. JW |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2012-05-22 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2012-05-22 |
Time |
10:59 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2012-04-25 |
Time |
14:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
N |
Date |
2012-07-23 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2012-07-23 |
Time |
17:15 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2012-07-09 |
Time |
13:58 |
Sent To |
B |
|
Notes |
2012-07-23 17:16:34 | SEE FREDERIEK'S HISTORICAL APPROVAL. | 2012-07-09 13:59:24 | HISTORIC PROPERTY - GIVEN TO FM FOR REVIEW. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2012-05-10 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2012-05-10 |
Time |
11:52 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2012-05-10 |
Time |
11:52 |
Sent To |
|
|
Notes |
|
|