Plan Review Details - Permit 12040512
Plan Review Stops For Permit 12040512 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2012-06-01 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-06-01 |
Time |
11:09 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-06-01 |
Time |
11:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2012-05-29 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-05-29 |
Time |
15:18 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-05-29 |
Time |
15:18 |
Sent To |
|
|
Notes |
2012-05-29 15:31:20 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | 1. PLEASE SUBMIT DETAILS FOR ALL CONNECTIONS FOR THE | | PROPOSED INSTALLATION. FOR EXAMPLE, THE FOLLOWING PAGES | | ARE MISSING FROM THE PACKAGE SUBMITTED: | | | | PAGE 3-A | | PAGE 3-3 | | PAGE I, GENERAL NOTES | | | | DETAILS FOR: | | | | C1-3 AND C2-3 | | C3-3 | | C4-3 | | | | PLEASE REVIEW THE DETAIL ON PAGE 3-3 AND CONFIRM THAT | | PACKAGE HAS ALL DETAILS REFERENCED ON THIS PAGE. THE | | LISTED SHEETS ARE PROVIDED AS A CONVIENCE FOR THE | | CONTRACTOR; RESPONSIBILITY FOR SUBMITTAL OF ALL | | REQUIRED SHEETS WITH ALL REQUIRED DETAILS IS | | RESPONSIBILITY OF CONTRACTOR AND THE LIST MAY NOT BE | | COMPLETE. | | | | 2. TWO COMPLETE SETS OF PLANS REQUIRED. | | | | ONLY ONE SET WAS SUBMITTED. FAILURE TO PROVIDE TWO SETS | | MAY RESULT IN PERMIT ISSUANCE DELAYS AND ADDITIONAL | | FEES (ADMIN COST PLUS COPIES). | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2012-05-16 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-05-16 |
Time |
07:36 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-05-16 |
Time |
07:36 |
Sent To |
|
|
Notes |
2012-05-16 07:40:11 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | 1. THE SITE SPECIFIC FOR PROPOSED CONSTRUCTION WAS NOT | | PROVIDED. THE SHEETS PROVIDED ARE FROM TWO DIFFERENT | | CHAPTERS, SCREEN ROOM AND SCREEN ENCLOSURES. ISN'T THE | | PROPOSED CONSTRUCTION UNDER AN EXISTING ROOF AND OVER | | AN EXISTING SLAB? PROVIDE DETAILS FROM THE APPROPRIATE | | SECTION OF THE AAF GUIDE, INCLUDE SPAN CHARTS, ALL | | APPLICABLE DETAILS. | | | | NOTE - PREVIOUS SUBMITTAL COMMENTS WERE GIVEN TO | | CONTRACTOR VERBALLY, INCORRECT WIND SPEED AND EXPOSURE | | SUBMITTED, PLANS TO BE MINIMUM OF 140MPH V(ASD) | | EXPOSURE C. | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2012-05-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-05-07 |
Time |
11:27 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-05-07 |
Time |
11:27 |
Sent To |
|
|
Notes |
2012-05-07 12:43:36 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2010 | | FBC R FLORIDA BUILDING CODE 2010 RESIDENTIAL | | | | | | 1. GOVERNING CODE CHANGED EFFECTIVE MARCH 15, 2012. SEE | | FBC CHAPTER 35, AAF-10 REQUIRED. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2012-05-29 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-05-29 |
Time |
15:37 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-05-18 |
Time |
11:53 |
Sent To |
|
|
Notes |
2012-05-18 11:53:57 | INCOMING SENT TO S HILL. JW |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2012-05-16 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-05-16 |
Time |
07:41 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-05-09 |
Time |
16:19 |
Sent To |
|
|
Notes |
2012-05-09 16:20:48 | SENT TO S HILL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2012-05-07 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-05-07 |
Time |
12:43 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-04-19 |
Time |
12:47 |
Sent To |
|
|
Notes |
2012-04-20 12:47:56 | INCOMING SENT TO ZONING BOX. JW |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2012-04-25 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2012-04-25 |
Time |
13:49 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2012-04-24 |
Time |
13:36 |
Sent To |
B |
|
Notes |
2012-04-24 13:36:29 | GIVEN TO JR |
|
|
|