Plan Review Stops For Permit 12040085 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2013-01-02 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2013-01-02 |
Time |
10:05 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2013-01-02 |
Time |
10:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2012-10-11 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2012-10-11 |
Time |
08:24 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2012-10-11 |
Time |
08:58 |
Sent To |
|
|
Notes |
2012-10-11 08:46:39 | BUILDING PLAN REVIEW | | PERMIT:12040085 | | ADD: 4312 PINEWOOD | | CONT: ANCHOR GENERAL CONTRACTING | | TEL: (561)386-1266 | | | | 2010 FLORIDA BUILDING CODE- RESIDENTIAL W | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | 3RD REVIEW | | OCT. 11/2012 | | ACTION: DENIED | | | | NOTE: PLANS DATED FROM 5/15/2012 ARE PLANS FROM 2ND | | REVIEW, NO ADDITIONAL PLANS WERE SUBMITED!!!!!! | | | | BUILDING: | | 1) SEMI-COMPLIED. CHANGE OF OCCUPANCY FROM GARAGE | | UTILTY R-3 AN EFFICENCY UNIT. | | | | 2) COMPLIED.2 | | | | 3) 2ND REQUEST.CHANGE OF OCCUPANCY SCOPE OF WORK HAS | | CHANGED, THE VALUE OF THE PROJECT IS TO LOW PER CITY | | AMENDMENTS 109.3 VALUE NEEDS TO BE ADJUSTED TO REFLECT | | PROPOSED WORK TO BE COMPLETED UNDER THIS PERMIT. WPB | | ADMINISTRATIVE CODE. 109.3 BUILDING PERMIT VALUATIONS. | | IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE | | CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE, | | ELECTRICAL, GAS, MECHANICAL OR PLUMBING SYSTEMS APPEARS | | TO BE UNDERESTIMATED ON THE APPLICATION, THE PERMIT | | SHALL BE DENIED, UNLESS THE APPLICANT CAN SHOW | | DETAILED, QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED | | CONTRACTS (EXCLUDING LAND VALUE) TO MEET THE APPROVAL | | OF THE BUILDING OFFICIAL. FOR PERMITTING PURPOSES, | | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL | | REPLACEMENT VALUE TO INCLUDE STRUCTURAL, ELECTRIC, | | PLUMBING, MECHANICAL, INTERIOR FINISH, RELATIVE SITE | | WORK, ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | OVERHEAD AND PROFIT; EXCLUDING | | ONLY LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE | | LATEST PUBLISHED DATA OF NATIONAL CONSTRUCTION COST | | ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS | | PUBLISHED BY INTERNATIONAL CODE CONGRESS. FINAL | | BUILDING PERMIT VALUATION SHALL BE SET BY THE BUILDING | | OFFICIAL. | | | | 4) COMPLETED. | | | | 5) 3RD REQUEST, APPLICABLE CODES, A CHANGE OF OCCUPANCY | | IS NOT A LEVEL 3 ALTERATION PLEASE REVIEW 2010 EXST | | BLDG CODE CHAPTER 9 SECTION 901.3, WHEN A CHANGE OF | | OCCUPANCY OCCURS FOR THE FULL BUILDING THEN SECTION 902 | | THROUGH 912 SHALL APPLY. | | | | 6) 3RD REQUEST, PROVIDE A WIND LOAD ANALYSIS OF THE | | EXISTING STRUCTURE TO SHOW COMPLIANCE WITH THE | | APPLICABLE WIND LOAD PROVISIONS OF THE FLORIDA BUILDING | | CODE AS REQUIRED BY EXST BLDG CODE 907.2. | | | | 7) 3RD REQUEST, SUBMIT A STRUCTURAL DETAIL OF THE | | IN-FILL WALL AT TTHE GARGE OPENING PER CITY AMENDMENT | | 107.2.1.3. DISCREPANCY IN PLANS, SHEET A-1 INDICATES | | WOOD INFILL PEN SCRATCHED OUT, WHEREAS A2 SECTION B | | INDICATES CBS CONSTRUCTION DETAIL ON A2 INDICATES WOOD | | INFILL. | | | | 8-12) COMPLIED. | | | | 13) 3RD REQUEST, WITH THE BATHROOM ONLY BEING 4'-0" | | WIDE IT IS QUESTIONABLE IF THERE WILL BE 21" IN FRONT | | OF THE WATER CLOSET PER FBC-R 307.1. | | | | 14-15) COMPLIED. | | | | 16) SHOW COMPLIANCE WITH R303.8 FOR REQUIRED HEATING. | | | | 17) COMPLIED. | | | | 18) COMPLIED. | | | | 19) SHOW COMPLIANCE WITH FBC ENERGY CONVERSATION | | 101.4.1 & 101.4.5. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | NOTE: | | CHAPTER 553.80(2)(B) FLORIDA STATUTES STATES THAT A | | LOCAL GOVERNMENT SHALL IMPOSE A FEE OF FOUR TIMES THE | | FEE FOR PLAN REVIEW, IF PLANS ARE REJECTED THREE | | OR MORE TIMES FOR REPEATED FAILURE TO CORRECT A CODE | | VIOLATION. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2012-07-06 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2012-07-06 |
Time |
14:12 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2012-07-06 |
Time |
14:12 |
Sent To |
|
|
Notes |
2012-07-06 16:58:17 | BUILDING PLAN REVIEW | | PERMIT:12040085 | | ADD: 4312 PINEWOOD | | CONT: ANCHOR GENERAL CONTRACTING | | TEL: (561)386-1266 | | | | 2010 FLORIDA BUILDING CODE- RESIDENTIAL W | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | BUILDING: | | 1) CHANGE OF OCCUPANCY FROM GARAGE UTILTY R-3 AN | | EFFICENCY UNIT. | | | | 2) 2ND REQUEST, CONTRACTOR TO CHANGE SCOPE OF WORK ON | | THE PERMIT APPLICATION TO INCLUDE " CHANGE OF | | OCCUPANCY". | | | | 3) 2ND REQUEST.CHANGE OF OCCUPANCY SCOPE OF WORK HAS | | CHANGED, THE VALUE OF THE PROJECT IS TO LOW PER CITY | | AMENDMENTS 109.3 VALUE NEEDS TO BE ADJUSTED TO REFLECT | | PROPOSED WORK TO BE COMPLETED UNDER THIS PERMIT. | | WPB ADMINISTRATIVE CODE. 109.3 BUILDING PERMIT | | VALUATIONS. IF, IN THE OPINION OF THE BUILDING | | OFFICIAL, THE CLAIMED VALUATION OF | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | DENIED, UNLESS THE APPLICANT CAN SHOW | | DETAILED, QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED | | CONTRACTS (EXCLUDING LAND VALUE) TO MEET THE | | APPROVAL OF THE BUILDING OFFICIAL. FOR PERMITTING | | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL | | BE TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING | | ONLY LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE | | LATEST PUBLISHED DATA OF NATIONAL CONSTRUCTION | | COST ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.), | | AS PUBLISHED BY INTERNATIONAL CODE CONGRESS. | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | BUILDING OFFICIAL. | | | | 4) COMPLETED. | | | | 5) 2ND REQUEST, APPLICABLE CODES, A CHANGE OF OCCUPANCY | | IS NOT A LEVEL 3 ALTERATION PLEASE REVIEW 2010 EXST | | BLDG CODE CHAPTER 9 SECTION 901.3, WHEN A CHANGE OF | | OCCUPANCY OCCURS FOR THE FULL BUILDING THEN SECTION 902 | | THROUGH 912 SHALL APPLY. | | | | 6) 2ND REQUEST, PROVIDE A WIND LOAD ANALYSIS OF THE | | EXISTING STRUCTURE TO SHOW COMPLIANCE WITH THE | | APPLICABLE WIND LOAD PROVISIONS OF THE FLORIDA BUILDING | | CODE AS REQUIRED BY EXST BLDG CODE 907.2. | | | | 7) 2ND REQUEST, SUBMIT A STRUCTURAL DETAIL OF THE | | IN-FILL WALL AT TTHE GARGE OPENING PER CITY AMENDMENT | | 107.2.1.3. DISCREPANCY IN PLANS, SHEET A-1 INDICATES | | WOOD INFILL | | PEN SCRATCHED OUT, WHEREAS A2 SECTION B INDICATES CBS | | CONSTRUCTION DETAIL ON A2 INDICATES WOOD INFILL. | | | | 8-12) COMPLIED. | | | | 13) 2ND REQUEST, WITH THE BATHROOM ONLY BEING 4'-0" | | WIDE IT IS QUESTIONABLE IF THERE WILL BE 21" IN FRONT | | OF THE WATER CLOSET PER FBC-R 307.1. | | | | 14-15) COMPLIED. | | | | 16) SHOW COMPLIANCE WITH R303.8 FOR REQUIRED HEATING. | | | | 17) THE CONTRACTOR ELECTED TO USE NON-IMPACT GLAZING, | | PRODUCT APPROVALS WERE SUBMITTED BUT THE FOLLOWING | | INFORMATION IS STILL UNKNOWN: | | PROVIDE STORM PANEL INFORMATION WITH INSTALLATION | | SCHEDULE AND KEY PLAN WITH SPECIFIC ANCHORS AND | | MOUNTING TO BE USED FOR ALL NON-IMPACT GLAZING. FBC | | 1609.1.4. | | | | FL BLD CODE 2004 SECTION 106.3.3, | | 1609.1.4, 1714.5.1 & EXIST BUILD CODE 507.3. | | PROCEDURES: 1(B) A COMPLETE INSTALLATION | | SCHEDULE SUMMARIZING & IDENTIFYING OPENING SIZES, STORY | | HEIGHTS, UNIT MARK NUMBERS, UNIT SPANS/WIDTHS, UNIT | | STORM | | BAR REINFORCING REQUIREMENTS, WALL PRESSURE ZONES, SLAT | | TYPES, ETC., SHALL BE SUBMITTED AT TIME OF PERMIT | | APPLICATION | | TO FACILITATE PLAN REVIEW AND PERMIT ISSUANCE. | | | | 18) COMPLIED. | | | | 19) SHOW COMPLIANCE WITH FBC ENERGY CONVERSATION | | 101.4.1 & 101.4.5. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2012-05-08 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-05-08 |
Time |
16:45 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-05-08 |
Time |
10:07 |
Sent To |
|
|
Notes |
2012-05-08 12:01:00 | 2010 FBC EXISTING BUILDING | | | | CHANGE OF OCCUPANCY | | | | DENIED BY BUILDING | | | | 1) BASED ON THE 2010 FBC EXISTING BUILDING, THIS | | PROJECT IS CONSIDERED A CHANGE OF OCCUPANCY. THE | | PROPERTY APPRAISER INDICATES THAT THIS STRUCTURE IS A | | FINISHED DETACHED GARAGE WHICH IS A GROUP U OCCUPANCY | | TYPE. THE PLANS THAT WERE SUBMITTED SHOW HABITABLE | | SPACE AND IS CONSIDERED AN R3 OCCUPANCY. I WAS UNABLE | | TO LOCATE ANY INFORMATION THAT INDICATES THAT THE | | GARAGE WAS CONVERTED TO HABITABLE SPACE WITH THE | | REQUIRED PERMITS AND INSPECTIONS. | | | | 2) THE DESCRIPTION OF WORK ON THE PERMIT APPLICATION | | NEEDS TO BE CHANGED TO ADEQUATELY DESCRIBE THE SCOPE OF | | WORK WHICH IS A CHANGE OF OCCUPANCY. CITY AMENDMENTS | | 105.6.1 | | | | 3) THE VALUATION OF THE WORK PROPOSED ON THE PERMIT | | APPLICATION IS TOO LOW. FOR PERMITTING PURPOSES THE | | VALUATION SHALL BE THE TOTAL REPLACEMENT VALUE OF ALL | | WORK, DESIGN FEES, OVERHEAD AND PROFIT PER CITY | | AMENDMENTS 109.3. THE VALUE WILL ALSO NEED TO INCLUDE | | ANY ADDITIONAL COSTS OF THE WORK REQUIRED TO MAKE THE | | CHANGE OF OCCUPANCY CODE COMPLIANT. | | | | 4) BEFORE THE PERMIT CAN BE ISSUED, THE PLANS WILL BE | | REQUIRED TO BE REVIEWED BY PALM BEACH COUNTY TO | | DETERMINE IF ANY IMPACT FEES ARE DUE. | | | | 5) SPECIFY ON THE PLANS THE APPLICABLE BUILDING CODE, | | THE CLASSIFICATION OF WORK FROM CHAPTER 4 OF THE FBC | | EXISTING BUILDING AND THE WINDSPEED DATA PER FBC | | R301.2.1. | | | | 6) PROVIDE A WIND LOADS ANALYSIS OF THE EXISTING | | STRUCTURE TO SHOW THAT IT COMPLIES WITH THE APPLICABLE | | WIND LOAD PROVISIONS OF THE FLORIDA BUILDING CODE AS | | REQUIRED BY FBC EXISTING BUILDING 907.2. | | | | 7) SUBMIT A STRUCTURAL DETAIL OF THE IN-FILL WALL AT | | THE GARAGE DOOR OPENING PER CITY AMENDMENTS 107.2.1.3. | | | | 8) SUBMIT A SECTION OF THE EXTERIOR WALLS FROM THE | | FOUNDATION THROUGH THE ROOF, INCLUDING ASSEMBLY AND | | MATERIALS CONNECTOR TABLES. CITY AMENDMENTS 107.3.5.3 | | | | 9) SUBMIT TWO COPIES OF AN EXISTING FLOOR PLAN DRAWN TO | | A MINIMUM 1/8 INCH SCALE PER CITY AMENDMENTS 107.2.1.4. | | | | 10) SHOW COMPLIANCE WITH EMERGENCY ESCAPE AND RESCUE | | OPENING AT BEDROOMS AS REQUIRED BY FBC R10.1. | | | | 11) SHOW COMPLIANCE EGRESS DOOR AS REQUIRED BY FBC | | R311.2. | | | | 12) SHOW COMPLIANCE WITH R305.1 FOR REQUIRED MINIMUM | | HEIGHT. | | | | 13) PROVIDE PROPOSED FLOOR PLAN DRAWN TO A MINIMUM 1/8 | | INCH SCALE SHOWING ROOM AREA DIMENSIONS AND BATH | | FIXTURE CLEARANCES. FBC R304 AND R307 | | | | 14) SHOW COMPLIANCE WITH R303.3 FOR REQUIRED BATHROOM | | VENTILATION. | | | | 15) SHOW COMPLIANCE WITH R303.1 FOR REQUIRED LIGHT AND | | VENTILATION OF HABITABLE ROOMS. | | | | 16) SHOW COMPLIANCE WITH R303.8 FOR REQUIRED HEATING. | | | | 17) SHOW COMPLIANCE WITH R301.2.1.2 FOR PROTECTION OF | | GLAZED OPENINGS FROM WINDBORNE DEBRIS. | | | | 18) SHOW COMPLIANCE FOR ACCESSIBLE BATHROOM WITH A DOOR | | THAT HAS A 29-INCH CLEAR OPENING. FBC R320 | | | | 19) SHOW COMPLIANCE WITH FBC ENERGY CONSERVATION | | 101.4.1 AND 101.4.5 | | | | 20) PLEASE RESPOND IN WRITING TO THE REVIEW COMMENTS | | INDICATING HOW EACH ITEM HAS BEEN ADDRESSED. | | | | NOTE: DUE TO THE LARGE AMOUNT OF MISSING INFORMATION, | | ADDITIONAL REVIEW COMMENTS MAY RESULT WHEN THAT | | INFORMATION IS SUBMITTED. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2012-11-27 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2012-11-27 |
Time |
14:28 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2012-11-27 |
Time |
14:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2012-08-27 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2012-08-27 |
Time |
15:56 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2012-08-27 |
Time |
15:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2012-07-09 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2012-07-06 |
Time |
14:05 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2012-07-06 |
Time |
14:50 |
Sent To |
|
|
Notes |
2012-07-09 14:05:32 | SEE NOTES ON PLAN. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2012-04-23 |
Time |
|
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2012-04-23 |
Time |
14:49 |
Sent To |
|
|
Notes |
2012-04-23 14:57:03 | 12040085 | | 4312 PINEWOOD AVE. | | INTERIOR RENOVATION | | | | REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO | | INCLUDE INTERCONNECTED SMOKE DETECTORS IF THEY DO NOT | | ALREADY EXIST WITHIN THE RESIDENCE. IF THE RESIDENCE | | HAS GAS APPLIANCES, AN ATTACHED GARAGE OR A FIRE PLACE | | A CARBON MONOXIDE DETECTOR IS REQUIRED WITHIN TEN FEET | | OF EACH ROOM USED FOR SLEEPING. FBC R313 | | FOR THE NEW WALL SPACES ADD RECEPTACLES SO THAT NO WALL | | SPACE IS MORE THAN 6 FEET FROM A RECEPTACLE AND ALL | | WALL SPACES MORE THAN 2 FEET IN WIDTH HAVE A RECEPTACLE | | I.E. NEW CLOSET WALL. NEC 210.52 | | ALL NEW GENERAL PURPOSE OUTLETS INCLUDING THOSE IN THE | | BEDROOMS AND SMOKE ALARMS MUST BE AFCI PROTECTED. NEC | | 210.12 | | NEW RECEPTACLES MUST BE TAMPER RESISTANT. NEC 406.11 | | RECEPTACLES SHALL BE SPACED SO THAT AT NO POINT ALONG | | THE FLOOR IN ANY WALL IS MORE THAN 6 FEET FROM A | | RECEPTACLE OUTLET. NEC 210.52 | | THE NEW LIVING AREA REQUIRES A SWITCHED RECEPTACLE OR | | LIGHT AND A SWITCHED LIGHT AT OUTSIDE ENTRANCES. A GFCI | | PROTECTED RECEPTACLE IS REQUIRED OUTSIDE FRONT AND | | BACK. NEC 210.70 | | | | ROBERT LECKY | | ELECTRIC PLANS EXAMINER | | [email protected] | | 561-805-6718 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2019-04-09 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2019-04-09 |
Time |
13:04 |
Rev Time |
0.00 |
Received By |
skennedy |
Date |
2019-04-01 |
Time |
13:04 |
Sent To |
|
|
Notes |
2019-04-09 13:06:01 | REISSUE APPROVED 4/9/19. ACCEPTED NEW APPLICATION BY | | CGC OF RECORD. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2013-01-02 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2013-01-02 |
Time |
10:07 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2012-11-21 |
Time |
10:56 |
Sent To |
|
|
Notes |
2012-11-26 10:56:55 | SENT TO R3 SHELF FOR REVIEW. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2012-10-11 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2012-10-11 |
Time |
08:58 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2012-09-19 |
Time |
09:28 |
Sent To |
|
|
Notes |
2012-10-11 08:59:41 | PLEASE SEE ZONING 5TH REVIEW WAS UNDER THE 3RD REVIEW | | CYCLE. JW | 2012-09-20 09:29:19 | SENT TO ZONING BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2012-09-04 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2012-09-04 |
Time |
12:32 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2012-08-23 |
Time |
09:20 |
Sent To |
|
|
Notes |
2012-08-23 09:20:54 | R04 | 2012-08-23 08:00:15 | TO RM |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2012-07-09 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2012-07-09 |
Time |
14:06 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2012-05-17 |
Time |
13:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2012-05-08 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-05-08 |
Time |
16:45 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-04-04 |
Time |
14:33 |
Sent To |
|
|
Notes |
2012-04-10 12:17:44 | 4/10 PUT ON RESIDENTIAL BOARD (NEEDS MULTIPLE TRADES) | | | 2012-04-04 14:35:01 | INCOMING SENT TO BLDG <$5K. JW |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
N |
Date |
2013-01-02 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2013-01-02 |
Time |
10:00 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2013-01-02 |
Time |
10:00 |
Sent To |
|
|
Notes |
2013-01-02 10:02:00 | IMPACT FEES : | | 5/17/2012 | | MU-2012-8871 | | $1,093.12 PAID |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2012-05-08 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-05-08 |
Time |
14:30 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-05-08 |
Time |
14:30 |
Sent To |
|
|
Notes |
2012-05-08 14:34:24 | AN IMPACT FEE REVIEW BY PALM BEACH COUNTY IS REQUIRED. | | A STAMPED SET OF PLANS AND COPY OF THE PAID RECIEPT | | MUST BE SUBMITTED. 233-5025 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
N |
Date |
2013-01-02 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2013-01-02 |
Time |
10:05 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2013-01-02 |
Time |
10:05 |
Sent To |
|
|
Notes |
2013-01-02 10:07:01 | MECHANICAL TO BE PULLED UNDER A SEPERATE PERMIT WITH | | SEPERATE PLANS, REVIEW AND ASSOCIATED FEES. JW |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2012-12-12 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2012-12-12 |
Time |
14:28 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2012-12-12 |
Time |
14:28 |
Sent To |
|
|
Notes |
2012-12-12 14:59:14 | *** MECHANICAL CORRECTIONS NEEDED *** | | | | NOTE: AS THE PREVIOUS WORK WAS DONE WITHOUT A PERMIT | | ALL MECHANICAL MUST BE INSPECTED. | | | | 1) SUBMIT ENERGY CALCULATIONS, PER 2010 FBC/ENERGY | | 401.3. | | | | 2) SUBMIT MECHANICAL PLANS SHOWING INFORMATION | | REGARDING AIR HANDLER UNIT, CONDENSER UNIT, AND DUCT | | WORK. STATE ON PLANS IF IT IS NEW OR EXISTING AND | | SHOWING IF THE AHU AND C/U ARE COMPATIBLE TO MEET THE | | REQUIRED SEER. CITY OF WPB AMEND. 107.3.5.3 (10). | | | | 3) SHOW THE SIZE OF THE BATHROOM WINDOW TO SHOW IF AN | | EXHAUST FAN IS NEEDED, SEE 2010 FBC/R M1507.1. | | | | 4) THE COOLING LOAD CALCULATIONS SUBMITTED STATES ONLY | | ONE TON OF A/C IS NEEDED, A COMMENT CAN NOT BE MADE AT | | THIS TIME AS THE SIZE OF THE A/C SYSTEM IS NOT KNOW. | | | | *** MECHANICAL PLAN REVIEW BY: TOM GORDON (HY-BYRD | | INC.) | | *** FOR ASSISTANCE CALL LUIS MARTINEZ (561) 805-6710 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2012-10-04 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2012-10-04 |
Time |
12:17 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2012-10-04 |
Time |
11:20 |
Sent To |
|
|
Notes |
2012-10-04 12:17:50 | CONTRACTOR WANTS TO CHANGE AIR HANDLER ONLY | | NEED A LETTER OF COMPATIBILITY . | | PER SECTION 107 GENERAL 2010 FBC | | PLAN REVIEW BY HAROLD MOSER | | 561-805-6732 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2012-07-09 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2012-07-09 |
Time |
13:39 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2012-07-09 |
Time |
13:39 |
Sent To |
|
|
Notes |
2012-07-09 13:45:05 | BUILDING PLAN REVIEW | | PERMIT:12040085 | | ADD: 4312 PINEWOOD | | CONT: ANCHOR GENERAL CONTRACTING | | TEL: (561)386-1266 | | | | 2010 FLORIDA BUILDING CODE- RESIDENTIAL W | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | MECHANICAL: | | | | SHEET A-1 INDICATES A NEW A/C UNIT NO OTHER INFORMATION | | ON UNIT IS PROVIDED NOR IS THERE ANY FORMS PROVIDING | | ENERGY COMPLIANCE. | | 2010 FBC-R 107.3.5.3 RESIDENTIAL (10) | | 10.MECHANICAL: EQUIPMENT AND LOCATION, DUCT SYSTEMS | | 13.ENERGY CALCULATIONS | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
N |
Date |
2013-01-02 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2013-01-02 |
Time |
10:02 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2013-01-02 |
Time |
10:02 |
Sent To |
|
|
Notes |
2013-01-02 10:04:46 | PLUMBING TO BE UNDER A SPERATE PERMIT, WITH SEPERATE | | PLUMBING RISER PLAN, REVIEW AND ASSOCIATED FEES . JW |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2012-10-11 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2012-10-11 |
Time |
08:55 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2012-10-11 |
Time |
08:55 |
Sent To |
|
|
Notes |
2012-10-11 08:57:59 | BUILDING PLAN REVIEW | | PERMIT:12040085 | | ADD: 4312 PINEWOOD | | CONT: ANCHOR GENERAL CONTRACTING | | TEL: (561)386-1266 | | | | 2010 FLORIDA BUILDING CODE- RESIDENTIAL W | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | RESIDENTIAL PLUMBING | | OCT. 11/2012 | | 3RD REVIEW | | | | NOTE SAME PLANS AS SUBMITTED FOR 2ND REVIEW DATED | | 5/15/12 | | NOTE: | | CHAPTER 553.80(2)(B) FLORIDA STATUTES STATES THAT A | | LOCAL GOVERNMENT SHALL IMPOSE A FEE OF FOUR TIMES THE | | FEE FOR PLAN REVIEW, IF PLANS ARE REJECTED THREE | | OR MORE TIMES FOR REPEATED FAILURE TO CORRECT A CODE | | VIOLATION. | | | | 1) THE PLUMBING ISOMETRIC FOR WASTE IS DRAWN | | INCORRECTLY: | | 1A) HAND DRAWN IS INDICATED A SECOND SINK, THERE IS | | ONLY ONE SINK SHOWN ON THE FLOOR PLAN, WHAT IS | | MISLABLED IS THE HAND DRAWN SINK, IT IS PROBABLY THE | | MISSING LAVATORY. | | 2010 FBC-R 3108.1. | | 1B) THE PLUMBING RISER HAS THE KITCHEN SINK TYING IN | | BEFORE THE WET VENT IT SHOULD TIE INTO THE MAIN | | BUILDING DRAIN AFTER THE WET VENT. | | 2010 FBC-R 3108.1. | | 1C) THE STACK AS DRAWN IS DIRECTLY BEHIND THE SINK | | WHICH WOULD PLACE IT DIRECTLY IN THE MIDDLE OF THE | | WINDOW, IT SHOULD BE ON ONE SIDE OF THE WINDOW. | | 107.3.5 MINIMUM CRITERIA PLAN REVIEW. | | 2) NO INFORMATION WAS PROVIDED ON THE PLUMBING AND | | SAFETY DEVICES FOR THE WATER HEATER. | | 2010 FBC-R 2805.1 PAN REQUIRED/ P2803.1 & 2803.6.1 | | REQUIREMENTS FOR DISCHARGE PIPE. | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2012-07-09 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2012-07-09 |
Time |
12:14 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2012-07-09 |
Time |
12:14 |
Sent To |
|
|
Notes |
2012-07-09 12:14:54 | BUILDING PLAN REVIEW | | PERMIT:12040085 | | ADD: 4312 PINEWOOD | | CONT: ANCHOR GENERAL CONTRACTING | | TEL: (561)386-1266 | | | | 2010 FLORIDA BUILDING CODE- RESIDENTIAL W | | * WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | RESIDENTIAL PLUMBING | | | | 1) THE PLUMBING ISOMETRIC FOR WASTE IS DRAWN | | INCORRECTLY: | | 1A) HAND DRAWN IS INDICATED A SECOND SINK, THERE IS | | ONLY ONE SINK SHOWN ON THE FLOOR PLAN, WHAT IS | | MISLABLED IS THE HAND DRAWN SINK, IT IS PROBABLY THE | | MISSING LAVATORY. | | 2010 FBC-R 3108.1. | | 1B) THE PLUMBING RISER HAS THE KITCHEN SINK TYING IN | | BEFORE THE WET VENT IT SHOULD TIE INTO THE MAIN | | BUILDING DRAIN AFTER THE WET VENT. | | 2010 FBC-R 3108.1. | | 1C) THE STACK AS DRAWN IS DIRECTLY BEHIND THE SINK | | WHICH WOULD PLACE IT DIRECTLY IN THE MIDDLE OF THE | | WINDOW, IT SHOULD BE ON ONE SIDE OF THE WINDOW. | | 107.3.5 MINIMUM CRITERIA PLAN REVIEW. | | 2) NO INFORMATION WAS PROVIDED ON THE PLUMBING AND | | SAFETY DEVICES FOR THE WATER HEATER. | | 2010 FBC-R 2805.1 PAN REQUIRED/ P2803.1 & 2803.6.1 | | REQUIREMENTS FOR DISCHARGE PIPE. | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2012-05-08 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-05-08 |
Time |
09:56 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-05-08 |
Time |
09:56 |
Sent To |
|
|
Notes |
2012-05-08 10:04:40 | 2010 FBC | | | | DENIED BY PLUMBING | | | | 1) THE RISER DIAGRAM DOES NOT SHOW ONE OF THE | | LAVATORIES SHOWN ON THE FLOOR PLAN. PLEASE CORRECT. | | CITY AMENDMENTS 107.2.1 | | | | 2) SPECIFY ALL OF THE PIPE SIZES ON THE SANITARY RISER | | DIAGRAM. CITY AMENDMENTS 107.2.1 | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
5 |
Status |
P |
Date |
2012-10-10 |
|
|
Cont ID |
|
Sent By |
mdekle |
Date |
2012-10-10 |
Time |
|
Rev Time |
0.00 |
Received By |
mdekle |
Date |
2012-10-10 |
Time |
14:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
F |
Date |
2012-09-25 |
|
|
Cont ID |
|
Sent By |
mdekle |
Date |
2012-09-25 |
Time |
|
Rev Time |
0.00 |
Received By |
mdekle |
Date |
2012-09-24 |
Time |
10:54 |
Sent To |
M |
|
Notes |
2012-09-25 08:20:38 | APPLICANT MUST PROVIDE SURVEY DEPICTING THE PROPOSED | | LOCATION OF THE A/C MECHANICAL EQUIPMENT. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2012-08-29 |
|
|
Cont ID |
|
Sent By |
lfranco |
Date |
2012-08-29 |
Time |
19:45 |
Rev Time |
0.00 |
Received By |
lfranco |
Date |
2012-08-29 |
Time |
19:45 |
Sent To |
|
|
Notes |
2012-08-29 19:49:09 | PLANNING: **** FAILED **** | | | | | | | | 1. RESPOND TO COMMENTS IN WRITING AND SUBMIT AS PART OF | | RESUBMITTAL PACKET. THE SUBMITTAL OF THE REQUESTED | | INFORMATION MAY GENERATE ADDITIONAL COMMENTS. | | | | 2. THE ZONING FOR THIS PROPERTY IS SINGLE-FAMILY LOW | | RESIDENTIAL ("SF7"), WHICH ALLOWS ONLY ONE (1) DWELLING | | UNIT, THAT ALREADY EXISTS. THIS PERMIT IS A PROPOSAL TO | | CONVERT AN EXISTING DETACHED GARAGE INTO A DWELLING | | UNIT, WHICH IS NOT ALLOWED UNDER THE CURRENT ZONING | | DISTRICT. | | | | NOTE: SURVEY WAS NOT REQUIRED DUE TO INTERIOR WORK ONLY | | (PER ANGELLA VANN, PLANNING AND ZONING ADMINISTRATOR). | | HOWEVER, ANY INSTALLATION OF MECHANICAL EQUIPMENT, ETC. | | ON THE OUTSIDE OF THE STRUCTURE WILL REQUIRE A SURVEY, | | WHICH SHOWS DIMENSIONS FROM ALL PROPERTY LINES. SEE | | ABOVE COMMENT #2, THE CONVERSION OF A GARAGE TO A | | DWELLING UNIT IS PROHIBITED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT, | | | | LINDA MIA FRANCO, AICP | | SENIOR PLANNER | | PLANNING AND ZONING DEPARTMENT | | TEL: (561) 822-1443 | | EMAIL: [email protected] | | | | | | | | 5/8/12 - ZONING REVIEW DUE TO ADDTL. INFORMATION FROM | | BLDG (RMCD). | | | | | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2012-05-08 |
|
|
Cont ID |
|
Sent By |
lfranco |
Date |
2012-05-08 |
Time |
14:16 |
Rev Time |
0.00 |
Received By |
lfranco |
Date |
2012-05-08 |
Time |
14:15 |
Sent To |
|
|
Notes |
2012-05-08 14:23:06 | PLANNING: **** FAILED **** | | | | | | 5/8/12 - ZONING REVIEW DUE TO ADDTL. INFORMATION FROM | | BLDG (RMCD). | | | | 1. RESPOND TO COMMENTS IN WRITING AND SUBMIT AS PART OF | | RESUBMITTAL PACKET. THE SUBMITTAL OF THE REQUESTED | | INFORMATION MAY GENERATE ADDITIONAL COMMENTS. | | | | 2. THE ZONING FOR THIS PROPERTY IS SINGLE-FAMILY LOW | | RESIDENTIAL ("SF7"), WHICH ALLOWS ONLY ONE (1) DWELLING | | UNIT, THAT ALREADY EXISTS. THIS PERMIT IS A PROPOSAL TO | | CONVERT AN EXISTING DETACHED GARAGE INTO A DWELLING | | UNIT, WHICH IS NOT ALLOWED UNDER THE CURRENT ZONING | | DISTRICT. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT, | | | | LINDA MIA FRANCO, AICP | | SENIOR PLANNER | | PLANNING AND ZONING DEPARTMENT | | TEL: (561) 822-1443 | | EMAIL: [email protected] | | | | | | | | | | | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2012-04-23 |
|
|
Cont ID |
|
Sent By |
lfranco |
Date |
2012-04-23 |
Time |
11:17 |
Rev Time |
0.00 |
Received By |
lfranco |
Date |
2012-04-23 |
Time |
11:17 |
Sent To |
|
|
Notes |
2012-04-23 11:19:23 | PLANNING: **** PASSED, *ZONING REVIEW NOT REQUIRED: | | INTERIOR WORK ONLY AND THE VALUE OF PROPOSED WORK DOES | | NOT EXCEED 50% OF THE IMPROVEMENT VALUE. **** | | |
|
|