Plan Review Details - Permit 12030654
Plan Review Stops For Permit 12030654 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2012-03-28 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-03-28 |
Time |
15:07 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-03-28 |
Time |
15:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2012-04-19 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2012-04-19 |
Time |
12:59 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2012-04-19 |
Time |
12:59 |
Sent To |
|
|
Notes |
2012-04-19 13:00:56 | PLANS REDLINED PER CONTRACTORS REQUEST.RL |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2012-04-06 |
|
|
Cont ID |
|
Sent By |
ddaniels |
Date |
2012-04-05 |
Time |
12:20 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2012-04-06 |
Time |
12:46 |
Sent To |
|
|
Notes |
2012-04-06 15:12:24 | 12030654 | | 3330 45TH ST #A | | INTERIOR WAREHOUSE REMODEL | | | | PROVIDE AN ELECTRICAL PERMIT. PROVIDE A PANEL SCHEDULE | | SHOWING RATING, SIZE AND WIRING METHOD FOR THE NEW | | ELECTRICAL CIRCUITS. NEC 210.3 | | A GFCI GENERAL PURPOSE RECEPTACLE MUST BE INSTALLED AT | | AN ACCESSIBLE LOCATION FOR THE SERVICE OF HEATING, AIR | | CONDITIONING, AND REFRIGERATION EQUIPMENT. NEC 210.63 | | SPECIFY ON THE PLANS HOW THE LIGHTING WILL BE | | CONTROLLED USING MOTION SENSORS OR SIMILAR TECHNIQUES | | AS REQUIRED BY THE FLORIDA BUILDING CODE. SPACE CONTROL | | FBC 13-415 ABC.1.2; ADDITIONAL CONTROLS 13-415.ABC.1.3, | | EXISTING BUILDING CODE 711.1 | | | | NOTE: | | SEPARATE PERMITS AND PLANS ARE REQUIRED FOR THE FIRE | | ALARM SYSTEM, VOICE AND DATA. | | | | | | | | ROBERT LECKY, CBO | | ELECTRIC PLANS EXAMINER | | [email protected] | | 561-805-6718 | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2012-04-24 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2012-04-24 |
Time |
10:03 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2012-04-24 |
Time |
09:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2012-04-05 |
|
|
Cont ID |
|
Sent By |
ddaniels |
Date |
2012-04-05 |
Time |
12:09 |
Rev Time |
0.00 |
Received By |
ddaniels |
Date |
2012-04-05 |
Time |
12:09 |
Sent To |
E |
|
Notes |
2012-04-05 12:20:40 | FIRE DEPARTMENT REVIEW ***DENIED*** | | ADDRESS:3330 45TH STREET SUITE A | | PERMIT # 12030654 | | CONTRACTOR: CAREY CONSTRUCTION COMPANY | | PHONE: 561 746-1440 | | | | 1.) ADDRESS ON PLANS DOES NOT MATCH THE ADDRESS ON THE | | PERMIT APPLICATION. | | 2.) DESIGN SHALL CONFORM TO THE 2010 EDITION OF THE | | FLORIDA FIRE PREVENTION CODE WHICH CONTAINS THE FLORIDA | | EDITION OF NFPA 1 AND NFPA 101. | | 3.) ALL DEMOLITION WORK SHALL CONFORM TO THE | | REQUIREMENTS OF NFPA 241. TRASH AND CONSTRUCTION DEBRIS | | SHALL BE REMOVED FROM THE SITE DAILY. | | 4.) SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE | | INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER | | SYSTEM AND/OR FIRE ALARM SYSTEM. | | 5.) EACH NEW SMOKE OR FIRE-RATED WALL/PARTITION SHALL | | BE PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING | | READING FIRE/SMOKE BARRIER?PROTECT ALL OPENINGS. | | CHARACTERS SHALL BE AT LEAST 4-INCHES IN HEIGHT AND | | HALF-INCH IN WIDTH. IDENTIFICATION SHALL BE SPACED NOT | | MORE THAN 15 FEET ON CENTER. REFERENCE SECTION 8.3.2.4 | | OF FLORIDA FIRE PREVENTION CODE ? NFPA 101 | | 6.) PENETRATIONS THROUGH A FIRE-RATED WALL ASSEMBLY | | SHALL BE PROTECTED BY A FIRESTOP SYSTEM OR DEVICE. | | REFERENCE SECTION 8.3.5.1 OF FLORIDA FIRE PREVENTION | | CODE ? NFPA 101 | | | | | | DERRICK L. DANIELS, BATTALION CHIEF | | WEST PALM BEACH FIRE RESCUE | | FIRE & LIFE SAFETY PLAN REVIEW | | (561) 805-6722 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2012-04-10 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-04-10 |
Time |
15:32 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-03-28 |
Time |
14:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2012-04-10 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2012-04-10 |
Time |
14:42 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2012-04-10 |
Time |
14:33 |
Sent To |
|
|
Notes |
|
|
|