Plan Review Stops For Permit 12030350 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2012-05-16 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-05-16 |
Time |
15:41 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-05-16 |
Time |
15:41 |
Sent To |
|
|
Notes |
2012-05-16 15:44:36 | BUILDING PROVISO | | | | THE DESIGNER OF RECORD IS TO SUBMIT A SIGNED AND SEALED | | LETTER LISTING ALL OF THE PRODUCT APPROVAL NUMBERS AND | | STATING THAT THEY HAVE BEEN REVIEWED AND APPROVED FOR | | USE IN HIS DESIGN. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2012-05-16 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-05-16 |
Time |
11:10 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-05-16 |
Time |
11:10 |
Sent To |
|
|
Notes |
2012-05-16 11:19:25 | 2007 FBC W/2009 REVISIONS | | | | DENIED BY BUILDING | | | | 1) THE PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD FOR | | THE PROJECT. CITY AMENDMENTS 106.3.3 | | | | 2) THE ENERGY CALCULATION FORM THAT WAS SUBMITTED IS | | THE ONE FOR THE 2010 FBC. PLEASE SUBMIT THE CORRECT | | FORMS FOR THE 2007 FBC. 2007 FBC ENERGY GLITCH | | AMENDMENTS N1100 | | | | 3) THE ENERGY CALCULATIONS THAT WERE SUBMITTED ARE | | WORST- CASE. THIS IS NOT PERMITTED FOR SIZING THE | | HEATING AND COOLING EQUIPMENT. PLEASE CORRECT. 2007 FBC | | ENERGY GLITCH | | AMENDMENTS N1107.AB.1 | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2012-04-04 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-04-04 |
Time |
13:35 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-04-04 |
Time |
06:44 |
Sent To |
|
|
Notes |
2012-04-04 13:42:00 | 2007 FBC W/2009 REVISIONS | | | | DENIED BY BUILDING | | | | 1) THE PROPOSED STRUCTURE IS LOCATED IN AN A5 FLOOD | | ZONE. THE MINIMUM FINISHED FLOOR ELEVATION IS 7.5 FEET | | B.F.E. PER CITY FLOOD ORDINANCE. PLEASE SPECIFY THE | | PROPOSED FLOOR ELEVATIONS ON THE PLANS. ELEVATION | | CERTIFICATES WILL BE REQUIRED. | | | | 2) ON SHEETS A3 AND A4 THE WRONG EXPOSURE CATEGORY IS | | SPECIFIED. THE STRUCTURE IS LOCATED IN EXPOSURE | | CATEGORY C PER FBC R301.2.1.4.3. PLEASE CORRECT. | | | | 3) THE COMPONENT AND CLADDING PRESSURES WILL NEED TO BE | | INCREASED TO CORRESPOND WITH EXPOSURE C. FBC R301.2.1 | | | | 4) SUBMIT TWO COPIES OF A SITE DRAINAGE PLAN COMPLYING | | WITH FBC R401.3. | | | | 5) THE ENERGY CALCULATION FORM SPECIFIES A VENTED ATTIC | | AND THE WALL SECTIONS ON SHEET D1 APPEAR TO SHOW AN | | UNVENTED ATTIC. PLEASE CLARIFY. IF ATTIC IS VENTED, | | SPECIFY THE ATTIC VENTILATION ON THE PLANS SHOWING | | COMPLIANCE WITH FBC R806. IF IT IS UNVENTED, SUBMIT TWO | | COPIES OF THE MANUFACTURER'S PRODUCT EVALUATIONS FOR | | THE SPRAY FOAM INSULATION. | | | | 6) FBC R613.6.1.1 REQUIRES WINDOW AND DOOR BUCKS TO BE | | THE FULL WIDTH OF THE FRAMES. PLEASE REVISE BUCK | | DETAILS. | | | | 7) A 30" ROOF OVERHANG IS SPECIFIED ON THE | | ARCHITECTURAL DRAWINGS AND A 12" ONE IS SHOWN ON THE | | STRUCTURAL PLANS. PLEASE COORDINATE PROJECTION OF THE | | OVERHANG. CITY AMENDMENTS 106.1.1 | | | | 8) SUBMIT TWO COPIES OF PRODUCT APPROVALS FOR THE 16' | | WIDE GARAGE DOOR AS REQUIRED BY DCA RULE 9N-3. THE ONE | | SUBMITTED HAS A MAXIMUM WIDTH LIMITATION OF 9 FEET. | | | | 9) PLEASE REVIEW THAT DESIGN PRESSURES FOR THE PRODUCTS | | THAT WERE SUBMITTED TO VERIFY THAT THEY WILL MEET THE | | INCREASED DESIGN PRESSURE REQUIREMENTS FOR EXPOSURE | | CATEGORY C. | | | | 10) THE PRODUCT APPROVALS ARE REQUIRED TO BE REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD FOR | | THE PROJECT. CITY AMENDMENTS 106.3.3 | | | | 11) THE OWNER/AGENT IS REQUIRED TO SIGN THE ENERGY | | CALCULATION FORMS. 2007 FBC ENERGY GLITCH AMENDMENTS | | N1100.2.2 | | | | 12) THE ENERGY CALCULATION FORM INCORRECTLY SPECIFIES | | 3525 SQUARE FEET UNDER ATTIC. A PORTION OF THIS | | STRUCTURE IS TWO STORIES. THERE IS A TOTAL OF 3525 SQFT | | OF CONDITIONED AREA AND THE SECOND FLOOR IS 1244 SQFT. | | PLEASE CORRECT THE FORM. 2007 FBC ENERGY GLITCH | | AMENDMENTS N1100 | | | | 13) THE ENERGY CALCULATIONS THAT WERE SUBMITTED ARE | | WORSE CASE. THIS IS NOT PERMITTED FOR SIZING THE | | HEATING AND COOLING EQUIPMENT. PLEASE CORRECT. 2007 FBC | | ENERGY GLITCH | | AMENDMENTS N1107.AB.1 | | | | 14) PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW THE | | REVIEW COMMENTS HAVE BEEN ADDRESSED. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2012-04-23 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2012-04-23 |
Time |
07:50 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2012-04-23 |
Time |
07:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2012-03-16 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2012-03-16 |
Time |
11:24 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2012-03-16 |
Time |
08:36 |
Sent To |
|
|
Notes |
2012-03-16 11:27:30 | PLANS REDLINED FOR SMOKE / CARBON MONOXIDE ALARMS AND | | 20 AMP BATHROOM CIRCUIT. | | | | ROBERT LECKY | | COMMERCIAL COMBINATION PLANS EXAMINER | | [email protected] | | 561-805-6718 | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
N |
Date |
2012-05-16 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-05-16 |
Time |
11:21 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-05-16 |
Time |
11:21 |
Sent To |
|
|
Notes |
2012-05-16 11:22:21 | SEE DRIVEWAY PERMIT #12050165 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2012-05-16 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-05-16 |
Time |
11:22 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-04-23 |
Time |
07:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2012-04-04 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-04-04 |
Time |
13:35 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-03-14 |
Time |
12:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2012-05-16 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-05-16 |
Time |
15:48 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-05-16 |
Time |
15:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2012-04-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-04-02 |
Time |
16:43 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-04-02 |
Time |
16:43 |
Sent To |
|
|
Notes |
2012-04-02 16:44:20 | AN IMPACT FEE REVIEW IS REQUIRED BY PALM BEACH COUNTY. | | BEFORE A PERMIT TO CONSTRUCT CAN BE | | ISSUED, IMPACT FEES MUST BE PAID TO | | PALM BEACH COUNTY. THE PLANS MUST BE | | STAMPED AND THE RECEIPT ATTACHED TO THE | | APPLICATION. 233-5025 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2012-05-16 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-05-16 |
Time |
15:46 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-05-16 |
Time |
15:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2012-05-16 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-05-16 |
Time |
07:56 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-05-15 |
Time |
16:36 |
Sent To |
|
|
Notes |
2012-05-16 08:28:56 | 2010 FBC | | | | DENIED BY MECHANICAL | | | | 1) THE ENERGY CALCULATIONS THAT WERE SUBMITTED ARE ON | | THE FORMS FOR THE 2010 FBC AND THIS PROJECT IS UNDER | | THE 2007 FBC. PLEASE SUBMIT THE CORRECT FORMS. 2007 FBC | | ENERGY GLITCH AMENDMENTS N1100.1 | | | | 2) THE HVAC EQUIPMENT CAN NOT BE SIZED USING WORST- | | CASE SIZING, THE ACTUAL BUILDING ORIENTATION MUST BE | | USED. SEE 2007 FBC ENERGY GLITCH AMENDMENTS N1107.AB.1 | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2012-04-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-04-03 |
Time |
09:57 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-04-03 |
Time |
09:57 |
Sent To |
|
|
Notes |
2012-04-03 10:27:35 | 2007 FBC W/2009 REVISIONS | | | | DENIED BY MECHANICAL | | | | 1) THE ENERGY CALCULATION FORMS ARE REQUIRED BY BE | | SIGNED BY THE OWNER/AGENT. 2007 FBC ENERGY GLITCH | | AMENDMENTS N1100.2.2 | | | | 2) SUBMIT TWO SETS OF MECHANICAL PLANS WITH DUCT LAYOUT | | AND EQUIPMENT SCHEDULE. SPECIFY THE DUCT AND GRILL | | SIZES, SPECIFY CFMS AT EACH DROP AND SHOW LOCATIONS OF | | ALL EQUIPMENT. CITY AMENDMENTS 106.3.5.4 | | | | 3) SHOW COMPLIANCE WITH FBCR M1602.4 FOR BALANCED | | RETURN AIR. | | | | 4) NOTE: THE STRUCTURE IS LOCATED IN AN A5 FLOOD ZONE | | WHICH REQUIRES ALL MECHANICAL EQUIPMENT TO BE LOCATED | | ABOVE 7.5 FEET BFE. AN ELEVATION CERTIFICATE WILL BE | | REQUIRED AT FINAL. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2012-05-15 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-05-15 |
Time |
16:35 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-05-15 |
Time |
16:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2012-04-03 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-04-03 |
Time |
09:51 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-04-03 |
Time |
09:51 |
Sent To |
|
|
Notes |
2012-04-03 09:57:37 | 2007 FBC W/2009 REVISIONS | | | | DENIED BY PLUMBING | | | | 1) SUBMIT TWO SETS OF SANITARY ISOMETRIC RISER | | DIAGRAMS. CITY AMENDMENTS 106.3.5.4 | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2012-05-03 |
|
|
Cont ID |
|
Sent By |
lfranco |
Date |
2012-05-03 |
Time |
16:50 |
Rev Time |
0.00 |
Received By |
lfranco |
Date |
2012-05-01 |
Time |
18:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2012-03-30 |
|
|
Cont ID |
|
Sent By |
lfranco |
Date |
2012-03-30 |
Time |
13:37 |
Rev Time |
0.00 |
Received By |
lfranco |
Date |
2012-03-28 |
Time |
15:20 |
Sent To |
|
|
Notes |
2012-03-30 13:46:10 | PLANNING: **** FAILED **** | | | | 1. RESPOND TO COMMENTS IN WRITING. | | | | 2. PROVIDE HEIGHT OF HOME TO THE TOP OF THE ROOFLINE. | | PURSUANT TO THE ZONING AND LAND DEVELOPMENT REGULATIONS | | ("ZLDR'), THE MAXIMUM HEIGHT ALLOWED IS 30 FEET. | | | | 3. INDICATE SETBACK DIMENSIONS FROM PROPOSED A/C | | EQUIPMENT TO ALL PROPERTY LINES. PURSUANT TO SECTION | | 94-305(B)(4) OF THE ZLDR: MECHANICAL EQUIPMENT MAY NOT | | PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK. | | | | 4. A SEPARATE LANDSCAPE PERMIT IS REQUIRED. PLEASE | | APPLY FOR A LANDSCAPE PERMIT THROUGH CONSTRUCTION | | SERVICES AND SUBMIT TWO COPIES OF THE LANDSCAPE PLAN. A | | CERTIFIED COST ESTIMATE THAT INCLUDES THE TOTAL COST OF | | ALL LANDSCAPE MATERIALS AND LABOR, BROKEN DOWN INTO | | UNIT COST SHALL BE INCLUDED. IS THERE EXISTING | | LANDSCAPING (TREES ON SITE). A TREE SURVEY SHALL BE | | PROVIDED SHOWING EXISTING VS. PROPOSED LANDSCAPING FOR | | THE SITE. | | | | 5. PLEASE PROVIDE THE TABULATION NECESSARY FOR THE | | EVALUATION OF COMPLIANCE WITH ARTICLE XIV OF THE ZONING | | AND LAND DEVELOPMENT REGULATIONS. | | | | 6. THE SURVEY SHOWS TWO PROPOSED WALLS AT EACH PROPERTY | | LINE. WHAT IS THE HEIGHT? PROVIDE ELEVATIONS AND | | INFORMATION ON PLANS. OTHERWISE, A SEPARATE PERMIT WILL | | BE REQUIRED, PRIOR TO BUILDING THE WALLS. REFER TO | | SECTION 94-302 FOR FENCES AND WALL HEIGHTS ALLOWED. | | WITHIN A FRONT SETBACK (25 FEET) A MAXIMUM HEIGHT OF 4 | | FEET IS ALLOWED. ON THE SIDES AND REAR, A MAXIMUM OF A | | 6-FOOT HEIGHT IS ALLOWED. | | | | POOL AND OTHER ACCESSORY STRUCTURES ARE NOT PART OF | | THIS PERMIT. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME. | | | | LINDA MIA FRANCO, AICP | | SENIOR PLANNER | | PLANNING DIVISION | | TEL: (561) 822-1443 | | EMAIL: [email protected] | | | | | | | | | | |
|
|