2012-04-11 12:08:02 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2007 | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. PROVIDE INFORMATION REGARDING THE LOCATION OF THE | | ACCESSIBLE ENTRANCE(S), FBC11 4.3.2, FBC 11 4. FBC 11 | | 4.6.2, ACCESSIBLE PARKING SPACES SERVING A PARTICULAR | | BUILDING SHALL BE LOCATED ON THE SHORTEST SAFELY | | ACCESSIBLE ROUTE OF TRAVEL FROM ADJACENT PARKING TO AN | | ACCESSIBLE ENTRANCE. SHOW ANY ELEVATION CHANGES IN THE | | ACCESSIBLE ROUTE. | | | | 2ND REVIEW, ACCESSIBLE PARKING SHOWN BUT ONE SPACE | | COMPELS THE USER TO WHEEL BEHIND A PARKED CAR. THIS IS | | PROHIBITED BY FBC 11-4.6.2(1). | | | | 2. FBC 11 4.3.2, SHOW ACCESSIBLE ROUTE FROM THE PUBLIC | | WAY TO THE ACCESSIBLE BUILDING ENTRANCE. | | | | NOT ADDRESSED. | | | | 3. ADVISORY ONLY, THE FOLLOWING WEBSITE MAY BE | | INFORMATIVE: | | HTTP://WWW.ADA.GOV/RESTRIPE.PDF | | | | 4-6. OK | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2012-03-13 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-03-13 |
Time |
15:39 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-03-13 |
Time |
15:39 |
Sent To |
|
|
Notes |
2012-03-13 15:47:52 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2007 | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. PROVIDE INFORMATION REGARDING THE LOCATION OF THE | | ACCESSIBLE ENTRANCE(S), FBC11 4.3.2, FBC 11 4. FBC 11 | | 4.6.2, ACCESSIBLE PARKING SPACES SERVING A PARTICULAR | | BUILDING SHALL BE LOCATED ON THE SHORTEST SAFELY | | ACCESSIBLE ROUTE OF TRAVEL FROM ADJACENT PARKING TO AN | | ACCESSIBLE ENTRANCE. SHOW ANY ELEVATION CHANGES IN THE | | ACCESSIBLE ROUTE. | | | | 2. FBC 11 4.3.2, SHOW ACCESSIBLE ROUTE FROM THE PUBLIC | | WAY TO THE ACCESSIBLE BUILDING ENTRANCE. | | | | 3. ADVISORY ONLY, THE FOLLOWING WEBSITE MAY BE | | INFORMATIVE: | | HTTP://WWW.ADA.GOV/RESTRIPE.PDF | | | | 4. THE DESIGNER TAKING RESPONSIBILITY FOR THIS DESIGN | | AND INFORMATION (AND CERTIFYING AS TO CODE COMPLIANCE) | | IS TO PROVIDE HIS/HER NAME AND SIGNATURE ON THE PLAN. | | | | 5. FBC 11-4.1.2(5)(A), THREE ACCESSIBLE SPACES | | REQUIRED. | | | | 6. ACCESS AISLE REQUIRED, FBC 11-4.6.6. REVISE PLAN TO | | SHOW REQUIRED ACCESS AISLES. | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2012-04-19 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-04-19 |
Time |
11:00 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-04-11 |
Time |
15:30 |
Sent To |
|
|
Notes |
2012-04-18 17:23:26 | TO ZONING FOR NEW SHEETS TO BE STAMPED | | | 2012-04-11 15:31:29 | IN ZONING BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2012-04-11 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-04-11 |
Time |
12:08 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-04-09 |
Time |
17:21 |
Sent To |
|
|
Notes |
2012-04-09 17:21:38 | SENT TO SAMANTHA'S DESK FOR REVIEW. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2012-03-13 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-03-13 |
Time |
15:47 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-03-01 |
Time |
16:25 |
Sent To |
|
|
Notes |
2012-03-01 16:25:52 | 3/01/2012 INCOMING SENT TO ZONING BOX. JW |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2012-04-16 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2012-04-16 |
Time |
15:51 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2012-04-13 |
Time |
08:47 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2012-03-13 |
|
|
Cont ID |
|
Sent By |
astelly |
Date |
2012-03-13 |
Time |
09:18 |
Rev Time |
0.00 |
Received By |
astelly |
Date |
2012-03-13 |
Time |
09:18 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |