|
 |
 |
 |
 |
 |
Plan Review Details - Permit 12010494
Plan Review Stops For Permit 12010494 |
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2012-02-28 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2012-02-28 |
Time |
10:00 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2012-02-28 |
Time |
10:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2012-01-30 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2012-01-30 |
Time |
11:51 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2012-01-30 |
Time |
11:48 |
Sent To |
|
|
Notes |
2012-01-30 11:50:59 | SCOPE OF ELECTRICAL WORK INSUFFICIENTLY DETAILED. | | ADDITIONAL INFORMATION MAY BE NEEDED. PLEASE PROVIDE | | THE FOLLOWING: | | | | INDICATE THE SIZE AND LOCATION OF THE ELECTRICAL PANEL. | | PROVIDE A PANEL SCHEDULE AND SUMMARY LOAD CALCULATION. | | SHOW THE SERVICE LOCATION, FEEDER SIZE AND EXISTING | | MAIN BREAKER. INCLUDE A FLOOR PLAN SHOWING THE LOCATION | | OF ALL NEW AND EXISTING OUTLETS INCLUDING LIGHTING. NEC | | 215.5 | | REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO | | INCLUDE INTERCONNECTED SMOKE DETECTORS IF THEY DO NOT | | ALREADY EXIST WITHIN THE RESIDENCE. IF THE RESIDENCE | | HAS GAS APPLIANCES, AN ATTACHED GARAGE OR A FIRE PLACE | | A CARBON MONOXIDE DETECTOR IS REQUIRED WITHIN TEN FEET | | OF EACH ROOM USED FOR SLEEPING. FBC R313 | | VERIFY THE BATHROOM RECEPTACLES ARE GFCI PROTECTED. NEC | | 210.8 | | INDICATE THAT ALL NEW RECEPTACLES WILL BE TAMPER | | RESISTANT. NEC 406.11 | | ALL NEW GENERAL PURPOSE BRANCH CIRCUITS MUST BE | | PROTECTED WITH ARC FAULT CIRCUIT INTERRUPTERS. NEC | | 210.12 | | BATHROOMS EACH REQUIRE A DEDICATED 20 AMP BRANCH | | CIRCUIT. NEC 210.11 (C) (3) | | AT LEAST ONE GFCI PROTECTED RECEPTACLE IS REQUIRED | | OUTSIDE FRONT AND BACK. NEC 210.70 | | | | ROBERT LECKY | | COMMERCIAL COMBINATION PLANS EXAMINER | | [email protected] | | 561-805-6718 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2012-02-28 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2012-02-28 |
Time |
10:00 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2012-02-27 |
Time |
16:12 |
Sent To |
|
|
Notes |
2012-02-27 16:13:15 | SENT TO ROBERT LECKY'S DESK FOR REVIEW. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2012-01-30 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2012-01-30 |
Time |
11:51 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2012-01-25 |
Time |
08:06 |
Sent To |
|
|
Notes |
2012-01-25 08:07:43 | INCOMING SENT TO <$5K BOX. JW |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |