Plan Review Stops For Permit 12010341 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2012-03-01 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-03-01 |
Time |
11:29 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-02-27 |
Time |
07:44 |
Sent To |
|
|
Notes |
2012-03-01 11:30:39 | PROVISO - SUBMIT PRODUCT APPROVALS FOR MULLIONS, ENTRY | | DOOR, AND SINGLE HUNG WINDOW AS A REVISION PRIOR TO | | INSTALLATION | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2012-02-02 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-02-02 |
Time |
10:19 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-01-31 |
Time |
12:01 |
Sent To |
|
|
Notes |
2012-02-02 10:19:32 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2007 | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | 1. IMPACT FEE ASSESSMENT REQUIRED; CONTACT 561-233-5025 | | FOR MORE INFORMATION. | | | | 2. FIREPLACE SPECS REQUIRED, FBC R1005. THIS MAY BE | | SUBMITTED AT THIS TIME OR WILL BE PROVISO ITEM TO | | SUBMIT AS A REVISION. | | | | 3. PROVIDE PRODUCT APPROVALS FOR THE ENTRY DOOR, | | MULLION, SINGLE HUNG WINDOW, FAC9N-3. THIS MAY BE | | SUBMITTED AT THIS TIME OR WILL BE A PROVISO ITEM TO | | SUBMIT AS A REVISION AFTER ISSUANCE. | | | | 4. DESIGN PRESSURES ON ARCHITECTURAL SHEETS APPEAR TOO | | LOW (FOR EXAMPLE, SHEET A02) AND IN CONFLICT WITH | | STRUCTURAL SHEET S0, FBC R301. PLEASE REMOVE FROM | | AFFECTED SHEETS OR CORRELATE WITH STRUCTURAL SHEETS. | | | | 5. SHEET A.08, STRUCTURAL CRITERIA, INCORRECTLY STATES | | 100 MPH FASTEST MILE NON WIND BORNE DEBRIS REGION. | | OTHER AREAS OF PLAN CORRECTLY DECLARE WIND DESIGN | | CRITERIA AS 140MPH, EXPOSURE C. AS THIS APPEARS TO BE A | | TYPO, PLEASE REMOVE LANGUAGE FROM PLAN TO AVOID | | POSSIBLE CONFLICTS, FBC R301. IF THIS IS NOT A TYPO AND | | IS DESIGN INTENT, PLEASE CONTACT ME TO DISCUSS. | | | | 6. M2, PROVIDE PRODUCT APPROVAL FOR THE MIAMI TECH CU | | TIE DOWNS, FAC9N 3. PLAN STATES THAT THESE ARE TO BE | | INSTALLED IN ACCORDANCE WITH MANUFACTURER?S | | INSTRUCTIONS, BUT I WAS UNABLE TO LOCATE THE PRODUCT | | WITH THIS DESCRIPTION ON THE INTERNET. PROVIDE SPEC | | SHEETS AND FASTENING PATTERN/CONFIGURATION TO SHOW HOW | | THE UNIT WILL RESIST WIND LOADS, FBC R301. | | | | 7. PROVIDE ORIGINAL SOILS INVESTIGATION REPORT, FS471. | | DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR | | PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | ORIGINALS. | | | | 8. ENERGY CALCS ARE INCOMPLETE. PLEASE PROVIDE CORRECT | | ENERGY CALCS, FBC 13 103.1.1.2. PREPARER AND | | OWNER/AGENT ARE TO READY ENERGY CALCS AND CERTIFY AS TO | | ACCURACY PRIOR TO SIGNING. | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2012-02-22 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2012-02-22 |
Time |
16:45 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2012-02-22 |
Time |
16:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2012-01-23 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2012-01-23 |
Time |
09:10 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2012-01-20 |
Time |
12:22 |
Sent To |
|
|
Notes |
2012-01-23 09:11:14 | 12010341 | | 235 EDMOR RD. | | NEW CUSTOM HOME | | | | CARBON MONOXIDE DETECTORS ARE REQUIRED WITHIN 10 FEET | | OF ALL SLEEPING AREAS. FBC R313 | | ADD RECEPTACLES SO THAT NO WALL SPACE IS MORE THAN 6 | | FEET FROM A RECEPTACLE AND ALL WALL SPACES MORE THAN 2 | | FEET IN WIDTH HAVE A RECEPTACLE I.E. WET BAR, FRONT | | ENTRY, BEDROOM 3, UNDER STAIRCASE ETC. NEC 210.52 | | PANEL BOARD FEEDERS APPEAR TO BE UNDERSIZED. MIN. 3/0 | | REQUIRED FOR 200 AMPERE BREAKER. NEC T. 310.16 | | PANEL ?C? EQUIPMENT GROUND SHOULD BE #6. NEC T. 250.122 | | INDICATE LOCATION OF ALL PANEL BOARDS AND THE | | ELECTRICAL SERVICE. NEC 215.5 | | | | ROBERT LECKY | | COMMERCIAL COMBINATION PLANS EXAMINER | | [email protected] | | 561-805-6718 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2012-03-09 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-03-08 |
Time |
07:38 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-02-16 |
Time |
15:32 |
Sent To |
|
|
Notes |
2012-02-16 15:32:53 | SENT TO R24 SHELF FOR REVIEW. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2012-02-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-02-02 |
Time |
15:32 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-01-18 |
Time |
10:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
P |
Date |
2012-03-01 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-03-01 |
Time |
13:14 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-03-01 |
Time |
13:14 |
Sent To |
|
|
Notes |
2012-03-01 13:15:06 | MU 2012 002569 0000 |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2012-03-01 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-03-01 |
Time |
08:23 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-03-01 |
Time |
08:22 |
Sent To |
|
|
Notes |
2012-03-01 08:24:28 | PROVIDE IMPACT FEE RECEIPT FOR 2012-2569 | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2012-02-02 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-02-02 |
Time |
07:59 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-02-02 |
Time |
07:59 |
Sent To |
|
|
Notes |
2012-02-02 08:08:11 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2007 | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | 1. IMPACT FEE ASSESSMENT REQUIRED. PLEASE CONTACT | | 561-233-5025 FOR MORE INFORMATION. THE PLANS ARE TO BE | | STAMPED AND THE RECEIPT, IF APPLICABLE, IS TO BE | | PROVIDED. | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2012-02-28 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-02-28 |
Time |
08:18 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-02-28 |
Time |
07:24 |
Sent To |
|
|
Notes |
2012-02-28 16:50:57 | REVISED PLANS REQUIRED SHOWING RETURN DUCT SIZES FOR | | A/H #1 @ WET BAR AND A/H #2 @ MASTER BEDROOM. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2012-02-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-02-02 |
Time |
15:31 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-01-31 |
Time |
14:28 |
Sent To |
|
|
Notes |
2012-02-02 15:48:51 | 2007 FBC W/2009 REVISIONS | | | | DENIED BY MECHANICAL | | | | 1) THE ENERGY CALCULATIONS ARE NOT COMPLETE. IT APPEARS | | THAT THERE MAY HAVE BEEN AN ERROR WITH THE PRINTER. | | PLEASE SUBMIT TWO COMPLETE COPIES OF THE ENERGY | | CALCULATIONS AS REQUIRED BY N1100.2 OF THE 2007 FBC | | ENERGY GLITCH AMENDMENTS. | | | | 2) THE HVAC SYSTEM HAS BEEN DESIGNED BY A DIFFERENT | | MECHANICAL CONTRACTOR THAN THE ONE THAT IS SIGNED ON | | THE PERMIT APPLICATION TO DO THE WORK. UNDER THE DESIGN | | AND BUILD EXEMPTION TO FLORIDA STATUTE 471.003(2)(H), | | THE MECHANICAL CONTRACTOR IS ALLOWED TO DESIGN THE | | SYSTEM ONLY IF IT IS INSTALLED BY HIM. SINCE THIS IS | | NOT THE CASE, THE MECHANICAL PLANS ARE REQUIRED TO BE | | SIGNED AND SEALED BY THE DESIGN ENGINEER. | | | | 3) ON SHEET M2 BOTH OF THE AIR HANDLERS FOR THE SECOND | | FLOOR ARE LABELED AHU #3. PLEASE CORRECT. CITY | | AMENDMENTS 106.1.1 | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2012-01-26 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-01-26 |
Time |
08:21 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-01-24 |
Time |
14:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2012-03-08 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2012-03-08 |
Time |
12:58 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2012-03-08 |
Time |
12:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2012-02-01 |
|
|
Cont ID |
|
Sent By |
lfranco |
Date |
2012-02-01 |
Time |
15:07 |
Rev Time |
0.00 |
Received By |
lfranco |
Date |
2012-02-01 |
Time |
15:04 |
Sent To |
|
|
Notes |
2012-02-01 15:19:24 | PLANNING: **** FAILED **** | | | | | | 1. RESPOND TO COMMENTS IN WRITING. | | | | 2. THE SURVEY AND THE SITE PLAN DIMENSIONS DO NOT | | MATCH. SURVEY SHOWS A DEPTH OF 96.7' AND SITE PLAN | | SHOWS 97'. REVISE ACCORDINGLY. SHOW UTILITY EASEMENT ON | | THE PLANS, PER SURVEY. | | | | 3. A SEPARATE PERMIT FOR THE DRIVEWAY WILL BE REQUIRED | | THROUGH THE ENGINEERING DEPARTMENT, IF THE SCOPE OF | | WORK SHOW ON THE SITE PLAN ARE EXCLUDING THE WORK. | | HOWEVER, SHOW DIMENSIONS WIDTH OF THE DRIVEWAY ON THE | | SITE PLAN. | | | | 4. WHAT ARE THE FOUR RECTANGULAR BOXES ON THE UPPER | | RIGHT HAND SIDE OF THE PLANS? | | | | 5.SHOW A/C ON SITE PLAN AND INDICATE SETBACK DIMENSIONS | | FROM PROPOSED A/C EQUIPMENT TO ALL PROPERTY LINES. | | PURSUANT TO SECTION 94-305(B)(4) OF THE ZLDR: | | MECHANICAL EQUIPMENT MAY NOT PROJECT MORE THAN 4 FEET | | INTO A REQUIRED SETBACK. | | | | NOTE: IF A PATIO OR PAVED AREA IS PROVIDED ADJACENT TO | | OR SURROUNDING A POOL, IT SHALL BE DESIGNED TO DRAIN | | AWAY FROM THE POOL, BUT NOT ONTO ADJACENT PROPERTIES. | | | | 6. PROVIDE HEIGHT OF BUILDING TO THE TOP OF THE ROOF | | LINE. THE MAXIMUM BUILDING HEIGHT IS 30 FEET. | | | | 7. SEPARATE LANDSCAPE AND IRRIGATION PERMITS ARE | | REQUIRED. TWO COPIES OF THE LANDSCAPE PLAN AND A | | CERTIFIED COST ESTIMATE THAT INCLUDES THE TOTAL COST OF | | ALL LANDSCAPE MATERIALS AND LABOR, BROKEN DOWN INTO | | UNIT COST SHALL BE SUBMITTED WITH THE LANDSCAPE PERMIT | | APPLICATION. | | | | 8. SUBMIT TWO COPIES OF THE IRRIGATION PLAN WITH THE | | IRRIGATION PERMIT APPLICATION. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME. | | | | LINDA MIA FRANCO, AICP | | SENIOR PLANNER | | PLANNING DIVISION | | TEL: (561) 822-1443 | | EMAIL: [email protected] | | |
|
|