Plan Review Stops For Permit 12010221 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2012-02-22 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2012-02-22 |
Time |
11:27 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2012-02-22 |
Time |
11:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2012-01-24 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2012-01-24 |
Time |
07:39 |
Rev Time |
0.55 |
Received By |
jwitmer |
Date |
2012-01-23 |
Time |
16:44 |
Sent To |
|
|
Notes |
2012-01-24 07:51:35 | BUILDING PLAN REVIEW | | PERMIT: 12010221 | | ADD: 5200 N FLAGLER DR # 2102 | | CONT: A& A DEVELOPMENT GROUP | | TEL: (561)719-0895 | | | | 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS | | * WEST PALM BEACH AMENDMENTS | | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | ACTION: DENIED | | | | 1) FL S S 489. THE ARCHITECTURAL PLAN DESIGNED BY THE | | REGISTERED ARCHITECT MICHAEL SIPULA HAS WHITE OUT ON IT | | AND APPEARS TO BE USED FROM A PREVIOUS CLIENT TASK IN | | UNIT #603 PERMIT # 11040193. PLEASE NOTE THAT | | ARCHITECTS WORK FALLS UNDER COPYRIGHT LAWS AND SUBJECT | | TO PENALTY AS SUCH. FL ADMIN 61G16.003. | | | | 2) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED | | WITH THE CLERK OF THE COURT. NOTE: 713.24(2) IF THE | | WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT | | ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2012-02-16 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2012-02-16 |
Time |
08:23 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2012-02-16 |
Time |
08:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2012-01-19 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2012-01-19 |
Time |
14:20 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2012-01-19 |
Time |
12:26 |
Sent To |
|
|
Notes |
2012-01-19 14:21:11 | 12010221 | | 5200 N. FLAGLER DR. #2102 | | INTERIOR CONDO RENOVATION | | | | SCOPE OF ELECTRICAL WORK INSUFFICIENTLY DETAILED. | | PLEASE PROVIDE THE FOLLOWING: | | INDICATE THE SIZE OF THE NEW ELECTRICAL PANEL. PROVIDE | | A PANEL SCHEDULE. SHOW THE FEEDER SIZE AND EXISTING | | OVER CURRENT PROTECTION. ON THE FLOOR PLAN SHOW THE | | LOCATION OF ALL NEW AND EXISTING LIGHTING OUTLETS, | | RECEPTACLE OUTLETS AND SMOKE DETECTORS. NEC 215.5 | | VERIFY THE KITCHEN COUNTER TOP RECEPTACLES AND BATHROOM | | RECEPTACLES ARE GFCI PROTECTED. NEC 210.8 | | INDICATE THAT ALL NEW RECEPTACLES WILL BE TAMPER | | RESISTANT. NEC 406.11 | | ALL NEW GENERAL PURPOSE BRANCH CIRCUITS MUST BE | | PROTECTED WITH ARC FAULT CIRCUIT INTERRUPTERS. NEC | | 210.12 | | | | ROBERT LECKY | | COMMERCIAL COMBINATION PLANS EXAMINER | | [email protected] | | 561-805-6718 | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2012-01-23 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2012-01-23 |
Time |
09:53 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2012-01-23 |
Time |
09:47 |
Sent To |
|
|
Notes |
2012-01-23 11:20:58 | DRAWINGS WILL BE STAMPED, INITIALED, AND DATED BY THE | | FIRE DEPARTMENT AFTER ALL PLAN REVIEWER COMMENTS HAVE | | BEEN SATISFIED. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2012-02-22 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2012-02-22 |
Time |
11:27 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2012-02-14 |
Time |
15:13 |
Sent To |
|
|
Notes |
2012-02-14 15:14:11 | GAVE TO LARRY |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2012-01-24 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2012-01-24 |
Time |
07:39 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2012-01-12 |
Time |
16:01 |
Sent To |
|
|
Notes |
2012-01-12 16:02:06 | SENT TO B6 SHELF FOR REVIEW. JG. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2012-02-15 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2012-02-15 |
Time |
13:26 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2012-02-15 |
Time |
13:17 |
Sent To |
E |
|
Notes |
2012-02-15 13:26:02 | FIXTURE SPACING SHALL BE PER FBC 2007 PLUMBING |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2012-01-19 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2012-01-19 |
Time |
10:23 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2012-01-18 |
Time |
13:01 |
Sent To |
|
|
Notes |
2012-01-18 13:26:20 | FBC 2007 PLUMBING REVIEW #1 | | DENIED: | | | | THE PLUMBING FIXTURES AS SHOWN ON A-1 APPEAR TO BE TOO | | CLOSE TOGETHER IN THE SPARE BATHROOM. THE WATER CLOSET | | LOOKS TO BE TOO CLOSE TO THE SHOWER IN THE MASTER | | BATHROOM. | | 405.3.1 WATER CLOSETS, URINALS, LAVATORIES AND BIDETS. | | A WATER CLOSET, URINAL, LAVATORY OR BIDET SHALL NOT BE | | SET CLOSER THAN 15 INCHES (381 MM) FROM ITS CENTER TO | | ANY SIDE WALL, PARTITION, VANITY OR OTHER OBSTRUCTION, | | OR CLOSER THAN 30 INCHES (762 MM) CENTER-TO-CENTER | | BETWEEN ADJACENT FIXTURES. THERE SHALL BE AT LEAST A | | 21-INCH (533 MM) CLEARANCE IN FRONT OF THE WATER | | CLOSET, URINAL, LAVATORY OR BIDET TO ANY WALL, FIXTURE | | OR DOOR. WATER CLOSET COMPARTMENTS SHALL NOT BE LESS | | THAN 30 INCHES (762 MM) WIDE AND 60 INCHES (1524 MM) | | DEEP (SEE FIGURE 405.3.1). | | | | ***NOTE*** | | THE PLANS ARE NOT SIGNED AND SEALED. | | | | REVIEW BY | | LARRY WAGNER | | CHIEF PLUMBING INSPECTOR | | PHONE # 805-6692 | | EMAIL [email protected] | | FAX # 805-6676 | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2012-01-13 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2012-01-13 |
Time |
15:53 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2012-01-13 |
Time |
15:53 |
Sent To |
|
|
Notes |
2012-01-13 15:54:43 | RESIDENTIAL INTERIOR RENOVATION DOES NOT EXCEED 50% OF | | BUILDING VALUE. |
|
|