Plan Review Details - Permit 12010221
Plan Review Stops For Permit 12010221
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2012-02-22 Cont ID  
Sent By jwitmer Date 2012-02-22 Time 11:27 Rev Time 0.00
Received By jwitmer Date 2012-02-22 Time 11:27 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-01-24 Cont ID  
Sent By jwitmer Date 2012-01-24 Time 07:39 Rev Time 0.55
Received By jwitmer Date 2012-01-23 Time 16:44 Sent To  
Notes
2012-01-24 07:51:35BUILDING PLAN REVIEW
 PERMIT: 12010221
 ADD: 5200 N FLAGLER DR # 2102
 CONT: A& A DEVELOPMENT GROUP
 TEL: (561)719-0895
  
 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 2007 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 ACTION: DENIED
  
 1) FL S S 489. THE ARCHITECTURAL PLAN DESIGNED BY THE
 REGISTERED ARCHITECT MICHAEL SIPULA HAS WHITE OUT ON IT
 AND APPEARS TO BE USED FROM A PREVIOUS CLIENT TASK IN
 UNIT #603 PERMIT # 11040193. PLEASE NOTE THAT
 ARCHITECTS WORK FALLS UNDER COPYRIGHT LAWS AND SUBJECT
 TO PENALTY AS SUCH. FL ADMIN 61G16.003.
  
 2) FL S S 713.13 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT. NOTE: 713.24(2) IF THE
 WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT
 ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)
 THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE
 CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2012-02-16 Cont ID  
Sent By rlecky Date 2012-02-16 Time 08:23 Rev Time 0.00
Received By rlecky Date 2012-02-16 Time 08:18 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2012-01-19 Cont ID  
Sent By rlecky Date 2012-01-19 Time 14:20 Rev Time 0.00
Received By rlecky Date 2012-01-19 Time 12:26 Sent To  
Notes
2012-01-19 14:21:1112010221
 5200 N. FLAGLER DR. #2102
 INTERIOR CONDO RENOVATION
  
 SCOPE OF ELECTRICAL WORK INSUFFICIENTLY DETAILED.
 PLEASE PROVIDE THE FOLLOWING:
 INDICATE THE SIZE OF THE NEW ELECTRICAL PANEL. PROVIDE
 A PANEL SCHEDULE. SHOW THE FEEDER SIZE AND EXISTING
 OVER CURRENT PROTECTION. ON THE FLOOR PLAN SHOW THE
 LOCATION OF ALL NEW AND EXISTING LIGHTING OUTLETS,
 RECEPTACLE OUTLETS AND SMOKE DETECTORS. NEC 215.5
 VERIFY THE KITCHEN COUNTER TOP RECEPTACLES AND BATHROOM
 RECEPTACLES ARE GFCI PROTECTED. NEC 210.8
 INDICATE THAT ALL NEW RECEPTACLES WILL BE TAMPER
 RESISTANT. NEC 406.11
 ALL NEW GENERAL PURPOSE BRANCH CIRCUITS MUST BE
 PROTECTED WITH ARC FAULT CIRCUIT INTERRUPTERS. NEC
 210.12
  
 ROBERT LECKY
 COMMERCIAL COMBINATION PLANS EXAMINER
 [email protected]
 561-805-6718
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2012-01-23 Cont ID  
Sent By wjolin Date 2012-01-23 Time 09:53 Rev Time 0.00
Received By wjolin Date 2012-01-23 Time 09:47 Sent To  
Notes
2012-01-23 11:20:58DRAWINGS WILL BE STAMPED, INITIALED, AND DATED BY THE
 FIRE DEPARTMENT AFTER ALL PLAN REVIEWER COMMENTS HAVE
 BEEN SATISFIED.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-02-22 Cont ID  
Sent By jwitmer Date 2012-02-22 Time 11:27 Rev Time 0.00
Received By jwitmer Date 2012-02-14 Time 15:13 Sent To  
Notes
2012-02-14 15:14:11GAVE TO LARRY

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-01-24 Cont ID  
Sent By jwitmer Date 2012-01-24 Time 07:39 Rev Time 0.00
Received By jwitmer Date 2012-01-12 Time 16:01 Sent To  
Notes
2012-01-12 16:02:06SENT TO B6 SHELF FOR REVIEW. JG.

Review Stop P PLUMBING
Rev No 2 Status P Date 2012-02-15 Cont ID  
Sent By lwagner Date 2012-02-15 Time 13:26 Rev Time 0.00
Received By lwagner Date 2012-02-15 Time 13:17 Sent To E
Notes
2012-02-15 13:26:02FIXTURE SPACING SHALL BE PER FBC 2007 PLUMBING

Review Stop P PLUMBING
Rev No 1 Status F Date 2012-01-19 Cont ID  
Sent By lwagner Date 2012-01-19 Time 10:23 Rev Time 0.00
Received By lwagner Date 2012-01-18 Time 13:01 Sent To  
Notes
2012-01-18 13:26:20FBC 2007 PLUMBING REVIEW #1
 DENIED:
  
 THE PLUMBING FIXTURES AS SHOWN ON A-1 APPEAR TO BE TOO
 CLOSE TOGETHER IN THE SPARE BATHROOM. THE WATER CLOSET
 LOOKS TO BE TOO CLOSE TO THE SHOWER IN THE MASTER
 BATHROOM.
 405.3.1 WATER CLOSETS, URINALS, LAVATORIES AND BIDETS.
 A WATER CLOSET, URINAL, LAVATORY OR BIDET SHALL NOT BE
 SET CLOSER THAN 15 INCHES (381 MM) FROM ITS CENTER TO
 ANY SIDE WALL, PARTITION, VANITY OR OTHER OBSTRUCTION,
 OR CLOSER THAN 30 INCHES (762 MM) CENTER-TO-CENTER
 BETWEEN ADJACENT FIXTURES. THERE SHALL BE AT LEAST A
 21-INCH (533 MM) CLEARANCE IN FRONT OF THE WATER
 CLOSET, URINAL, LAVATORY OR BIDET TO ANY WALL, FIXTURE
 OR DOOR. WATER CLOSET COMPARTMENTS SHALL NOT BE LESS
 THAN 30 INCHES (762 MM) WIDE AND 60 INCHES (1524 MM)
 DEEP (SEE FIGURE 405.3.1).
  
 ***NOTE***
 THE PLANS ARE NOT SIGNED AND SEALED.
  
 REVIEW BY
 LARRY WAGNER
 CHIEF PLUMBING INSPECTOR
 PHONE # 805-6692
 EMAIL [email protected]
 FAX # 805-6676
  
  

Review Stop Z ZONING
Rev No 1 Status N Date 2012-01-13 Cont ID  
Sent By eschneid Date 2012-01-13 Time 15:53 Rev Time 0.25
Received By eschneid Date 2012-01-13 Time 15:53 Sent To  
Notes
2012-01-13 15:54:43RESIDENTIAL INTERIOR RENOVATION DOES NOT EXCEED 50% OF
 BUILDING VALUE.