Plan Review Details - Permit 12010196
Plan Review Stops For Permit 12010196
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2012-01-13 Cont ID  
Sent By jnguyen Date 2012-01-13 Time 14:19 Rev Time 0.00
Received By jnguyen Date 2012-01-11 Time 13:22 Sent To  
Notes
2012-01-13 14:19:12INITIALLY, I CHECKED WITH JOHN ROACH TO FIND OUT IF
 THERE WERE ANY ADDITIONAL DEMOLITIONS IN THE AREA, BUT
 IT WAS NOT DEFINITIVE. THEREFORE, I DECIDED TO PROCEED
 WITH ADDRESSING IT BASED ON THE CURRENT LAYOUT. IN
 ADDRESSING, THE FRONTAGE OF A STRUCTURE IS USUALLY
 GIVEN MORE WEIGHT. DESPITE THE FACT THAT THIS BUILDING
 (WITH NINE RESIDENTIAL UNITS) APPEARED TO BE FACING
 DOUGLASS AVE, MORE PRIORITY WAS GIVEN TO ITS DRIVEWAY
 ACCESS, WHICH WAS EXCLUSIVELY OFF N TAMARIND AVE (DUE
 TO EMERGENCY SERVICES CONCERNS). I DECIDED NOT TO REUSE
 ADDRESSES THAT PREVIOUSLY REFERENCED DEMOLISHED
 STRUCTURES AT THIS LOCATION (RETIRED/DEACTIVATED
 ADDRESSES), SO I ASSIGNED NEW ADDRESSES OF 1860 N
 TAMARIND AVE # 1-9 (UNITS GOING FROM SOUTH TO NORTH)
 FOR THIS BUILDING. I OBTAINED A DIGITAL SITE PLAN FROM
 THE ARCHITECT, DAVID LAWERENCE, THEN I PROCEEDED WITH
 SENDING OUT THE OFFICIAL E-MAIL NOTIFICATION. I HAVE
 RETURNED THE PLANS & DOCUMENTS BACK DOWNSTAIRS.
  
 JOHN NGUYEN
 GIS SUPPORT SPECIALIST
 CITY OF WEST PALM BEACH
 PUBLIC UTILITIES DEPARTMENT
 OFFICE: (561) 822-1239
 FAX: (561) 822-1249
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2012-12-11 Cont ID  
Sent By jwitmer Date 2012-12-11 Time 12:21 Rev Time 0.00
Received By jwitmer Date 2012-12-11 Time 12:16 Sent To  
Notes
2012-12-11 12:21:51BUILDING PLAN REVIEW
 PERMIT: 12010196
 ADD: 1860 N TAMARIND AVE.
 CONT: HARTNETT BUILDING GROUP
 TEL: (561)523-5902
  
 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
  
  
 PROVISO: 11/09/2012 ARCHITECT IS LOOK AT OPTIONS FOR
 SAFETY GLAZING.
 SHEET A2.1 WINDOW SCHEDULE NOTE # 3 INDICATES ALL
 SAFETY GLAZING IN HAZARDOUS AREAS SHALL BE TEMPERED.
 THE WINDOW SCHEDULE DOES INDICATE
 WINDOW TYPE E BUT NOT TYPE A WHERE THE WINDOW WILL BE
 NEXT TO THE STAIR IS THE DESIGNER USING THE LARGE
 MISSILE TESTED LAMINATED GLAZING AS MEETING THE SAFETY
 GLAZING REQUIREMENTS UNDER 2406.4.
  
 ROOFING : FL GAF-ELK ASPHALT ROOF SHINGLES
 FL 10124-R3
 EVAL RE: 01506.01.08-R4
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2012-10-31 Cont ID  
Sent By jwitmer Date 2012-10-31 Time 09:40 Rev Time 0.00
Received By jwitmer Date 2012-10-31 Time 08:46 Sent To  
Notes
2012-10-31 10:54:21BUILDING PLAN REVIEW
 PERMIT: 12010196
 ADD: 1860 N TAMARIND AVE.
 CONT: HARTNETT BUILDING GROUP
 TEL: (561)523-5902
  
 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 2ND REVIEW
 OCT. 31/ 2012
 ACTION: DENIED
  
 1) 11/09/2012 COMPLIED, AARCHITECT RED LINED PLANS.
 SHEET A1.1 SEMI- COMPLIED. THE PLANS ARE MISSING THE
 ACCESS AISLE AS REQUIRED BY ANSI 4.6. SITE PLAN DOES
 NOT COMPLIANCE WITH THE FAIR HOUSING ACT, AND ANSI
 A117.1 4.3 ACCESSIBLE ROUTE, AN ACCESSIBLE ROUTE TO ALL
 SITE AMENITIES (DUMPSTER), PARKING SPACES, ACCESS
 AISLES, CURB RAMPS, RAMPS SLOPES, CROSS SLOPES &
 ACCESIBILTY TO PUBLIC TRANS PORTATION.
 \
  
 12) COMPLIED. 11/14/2012 CLARIFICATION LETTER FROM
 ONMJ.
 2ND REQUEST. SHEET S1 VERSES SHEET A2.1 DOOR # 2 IS
 INDICATED AS A 6'-0" WIDE DOOR OPENING, WHERE AS S1
 INDICATES TTHE BLOCK OPENING TO BE NARROWER. PLEASE
 ALSO REVIEW THE BEAM SCHEDULE ON S3, VERSES S1 AND S2
 ALL BEAMS ARE LABELED BB-1 WITH NO STIRRUPS OR HOOPS
 (HAIRPINS DETAIL 4 / SHEET S4) ) OVER THE WINDOWS AND
 DOORS. ACI 530 # 7.5.3.1 SHEAR REINFORCEMENT SHALL BE
 PROVIDED PARALLEL TO THE DIRECTION OF APPLIED FORCE.
 SPACING OF SHEAR REINFORCEMENT SHALL NOT EXCEED THE
 LESSEER OF D/2 OR 48 INCHES.
  
 13-15) COMPLIED.
  
 16) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 NEW COMMENTS
  
 17) 11/09/2012 COMPLIED, AARCHITECT RED LINED PLANS.
 SHEET A2.1 PLEASE REVIEW EGRESS WINDOW NOTE IN REGARDS
 TO TOTAL GLAZED AREA VERSES THE REQUIRED CLEAR OPENING
 REQUIREMENTS FOR FIRST FLOOR VERSES SECOND FLOOR. 2007
 FBC-B SECTION 1026.2.
  
 18) PROVISO: 11/09/2012 ARCHITECT IS LOOK AT OPTIONS
 FOR SAFETY GLAZING.
 SHEET A2.1 WINDOW SCHEDULE NOTE # 3 INDICATES ALL
 SAFETY GLAZING IN HAZARDOUS AREAS SHALL BE TEMPERED.
 THE WINDOW SCHEDULE DOES INDICATE
 WINDOW TYPE E BUT NOT TYPE A WHERE THE WINDOW WILL BE
 NEXT TO THE STAIR IS THE DESIGNER USING THE LARGE
 MISSILE TESTED LAMINATED GLAZING AS MEETING THE SAFETY
 GLAZING REQUIREMENTS UNDER 2406.4.
  
 19) 11/14/2012 LETTER FROM ARCHITECT DAVID LAWRENCE TO
 DOUG WISE B.O. ASKING FOR REVIEW OF ALTERNATE MATERIALS
 & METHODS, SUBMITTED TO ROBERT BROWNS OFFICE. JW.
  
 11/09/2012 ARCHITECT IS TO WRITE LETTER FOR ALTERNATE
 MATERIALS AND METHODS 2010 FBC ADMINISTRATIVE CODE
 104.11.THE COVERSHEET A1.0 UNDER THE BUILDING DESIGN
 LIST THIS BUILDING AS A TYPE V-B UNSPRINKLERED. BOTH
 THE BUILDING AND FIRE CODES REQUIRE ALL R TYPE
 OCCUPANCIES TO BE FIRE SPRINKLERED WIT THE EXCEPTION OF
 ONE AND TWO FAMILY DWELLINGS THAT ARE REVIEWED UNDER
 THE 2007 FBC-R RESIDENTIAL CODE.
 2007-09 FBC-B 903.2.7 REQUIRES FIRE SPRINKLERS. WE DO
 UNDERSTAND THERE WAS TALK WITH THE FIRE DEPARTMENT
 ABOUT FIRE SPRINKLER REQUIREMENTS BUT NO OTHER
 INFORMATION HAS BEEN PROVIDED BY THE FIRE DEPARTMENT AS
 TO THE RESULTS OF SUCH MEETING. CHIEF DANIELS HAS
 ENTERED IN THE PLAN REVIEW FIELD RESULTS THAT A MEETING
 WITH THE DESIGNER HAD OCCURED WHICH HAS KEPT THE PERMIT
 ALIVE SINCE THE LAST LISTED ACTIVITY. THE DESIGNER OF
 RECORD ON THE COMMENT RESPONCE SHEET INDICATES THEY ARE
 GOING WITH A PERFORMANCE BASED METHOD IN LEIU OF FIRE
 SPRINKLERS. THE COVER SHEET DOES NOT INDICATE A
 PREFORMANCE BASED METHOD VERSES FIRE SPINKLERS. IF THE
 DESIGNER OF RECORD IS PROPOSING TO USE ALTERNATE
 MATERIALS, DESIGN AND METHODS OF CONSTRUCTION (104.11
 WEST PALM BEACH ADMINISTRATIVE CODE) A LETTER TO THE
 BUILDING OFFICIAL REQUESTING THE USE OF ALTERNANTE
 MATERIAL AND METHODS TO BE SUBSTITUTED. WHEN ALTERNANTE
 LIFE SAFETY SYSTEMS ARE DESIGNED, THE SFPE ENGINEERING
 GUIDE OF PERFORMANCE- BASED FIRE PROTECTION ANALYSIS
 AND DESIGN OF BUILDINGS OR OTHER METHODS APPROVED BY
 THE BUILDING OFFICIAL MAY BE USED.
  
 NOTE NO PRODUCT APPROVALS HAVE BEEN SUBMITTED FOR
 ROOFING AT THIS TIME, A SEPERATE PERMIT, REVIEW AND
 ASSOCIATED FEES SHALL OCCUR.
  
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2012-01-25 Cont ID  
Sent By jwitmer Date 2012-01-19 Time 16:11 Rev Time 0.00
Received By jwitmer Date 2012-01-19 Time 11:37 Sent To  
Notes
2012-01-20 11:02:35BUILDING PLAN REVIEW
 PERMIT: 12010196
 ADD: 1860 N TAMARIND AVE.
 CONT: HARTNETT BUILDING GROUP
 TEL: (561)523-5902
  
 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) SHEET A1.1 SITE PLAN DOES NOT COMPLIANCE WITH THE
 FAIR HOUSING ACT, AND ANSI A117.1 4.3 ACCESSIBLE ROUTE,
 AN ACCESSIBLE ROUTE TO ALL SITE AMENITIES (DUMPSTER),
 PARKING SPACES, ACCESS AISLES, CURB RAMPS, RAMPS
 SLOPES, CROSS SLOPES & ACCESIBILTY TO PUBLIC TRANS
 PORTATION.
  
 2) SHEET A3.1 UNIT A AND (REVERSE A) BOTH INDICATE A
 BI-FOLD DOOR # 3 WITH A WIDTH OF 2'-6" PLEASE SEE ANSI
 4.13 FOR INTERIOR USABLE DOORS TO HAVE A CLEAR WIDTH OF
 32 INCHES.
  
 3) SHEET A3.1 UNIT A AND REVERSE A PLEASE DIMENSION
 FROM THE SINK CENTERLINE TO THE INSIDE CORNER AS WELL
 AS FROM THE INSIDE CORNER TO THE CENTER LINE OF THE
 STOVE. PLEASE PROVIDE THE CLEAR FLOOR SPACE (30X48)
 CENTER-LINED ON THE APPLIANCES IT APPEARS THERE MAY NOT
 BE ENOUGH ROOM TO ACCOMADATE THE CLEAR FLOOR SPACE FOR
 A SIDE APPROACH.
  
 4) SHEET A3.1 UNIT D INDICATES A BI-FOLD DOOR # 2 WITH
 A WIDTH OF 2'-6" PLEASE SEE ANSI 4.13 FOR INTERIOR
 USABLE DOORS TO HAVE A CLEAR WIDTH OF 32 INCHES.
  
 5) SHEET A3.1 UNIT D PLEASE DIMENSION FROM THE SINK
 CENTERLINE TO THE INSIDE CORNER AS WELL AS FROM THE
 INSIDE CORNER TO THE CENTER LINE OF THE STOVE. PLEASE
 PROVIDE THE CLEAR FLOOR SPACE (30X48) CENTER-LINED ON
 THE APPLIANCES IT APPEARS THERE MAY NOT BE ENOUGH ROOM
 TO ACCOMADATE THE CLEAR FLOOR SPACE FOR A SIDE
 APPROACH.
  
 6) SHEET A3.1 FOR BOTH A & D BATHROOM UNITS PLEASE
 DIMENSION LAVATORY AND WATER CLOSET LOCATIONS FROM WALL
 TO CENTER LINE OF FIXTURE AND OR FROM CENTERLINE OF
 FIXTURE TO CENTERLINE OF FIXTURE. PLEASE PROVIDE WHICH
 TYPE OF RESTROOM TYPE A OR B HAS BEEN PROVIDED.
  
 7) SHEET A3.2 FOR B UNIT & A3.3 FOR C UNIT BOTH ARE
 MISSING ATTIC ACCESS FBC-B 11209.2.
  
 8) SHEET A5.2 THE SINGLE STORY CUT SECTION OF WALL DOES
 INDICATE THE USE OF FIRE BLOCKING AT THE CEILING LINE
 BUT THE 2 STORY DETAILS DO NOT INDICATE THE USE OF FIRE
 BLOCKING AT THE CEILING.
  
 9) SHEET A5.2 FIRE BLOCKING NOTE # 2 INDICATES THE USE
 OF FIBERGLASS BATTS AND BLANKETS AS AN ALTERNATIVE
 FIREBLOCKING MATERIAL. PLEASE PROVIDE THE MANUFACTURERS
 SPEC FOR THIS TYPE INSULATION TO BE USED AS A FIRE
 BLOCKING MATERIAL. 106.1.2 ADDITIONAL INFORMATION
 REQUIRED.
  
 10) SHEET A6.1 INDICATES THE USE OF WOOD SUB-BUCKS AT
 WINDOWS AND DOOR. THE DETAILS INDICATE THAT THE BUCKS
 ARE NOT AS WIDE AS THE DOOR OR WINDOW FRAME. PLEASE
 REVIEW FBC-B 1714.5.4.2. MASONRY, CONCRETE OR OTHER
 STRUCTURAL SUBSTRATE.
  
 11) PLEASE REVIEW SHEET S-1 VERSES A3.1, SHEET S-1 FOR
 UNITS D, UNIT A AND REVERSE A THEY ALL SHOW A DROPPED
 MONOLITHIS SLAB AT THE FRONT ENTRY PORCH VERSES A3.1
 WHICH INDICATES THE ENTRY PORCH FLOOR LEVEL WITH THE
 INTERIOR SLAB SINCE THESE UNITS ARE FAIR HOUSING
 NEEDING AN ACCESSIBLE ENTRY.
  
 12) SHEET S1 VERSES SHEET A2.1 DOOR # 2 IS INDICATED AS
 A 6'-0" WIDE DOOR OPENING, WHERE AS S1 INDICATES TTHE
 BLOCK OPENING TO BE NARROWER. PLEASE ALSO REVIEW THE
 BEAM SCHEDULE ON S3, VERSES S1 AND S2 ALL BEAMS ARE
 LABELED BB-1 WITH NO STIRRUPS OR HOOPS OVER THE WINDOWS
 AND DOORS. ACI 530 # 7.5.3.1 SHEAR REINFORCEMENT SHALL
 BE PROVIDED PARALLEL TO THE DIRECTION OF APPLIED FORCE.
 SPACING OF SHEAR REINFORCEMENT SHALL NOT EXCEED THE
 LESSEER OF D/2 OR 48 INCHES.
  
 13) SHEET A2.1 UNIT B UPSTAIRS RESTROOM WINDOW TYPE B,
 THE SILL HEIGHT IS UNKNOWN MAY OR MAY NOT BE CLASSIFIED
 AS A HAZARDOUS LOCATION FBC-B 2406.3.
  
 14) SHEET A2.1 UNIT B UPSTAIRS FRONT WINDOW TYPE "B"
 WILL NEED PRODUCT APPROVAL FOR MULLIONS. THE PGT SH-800
 ALUMINUM SINGLE HUNG REPORT 07-0801.03 DOES NOT
 INDICATE THE USE OF MULLIONS WITHIN THE REPORT. FBC-B
 1609 COMPONENTS AND CLADDING & RULE 9N-3(31)(B).
  
 15) SHEET A2.1 NOTE FOR HOLLOW METAL EXTERIOR DOOR NOA
 # 10-0209.07 NO APPROVALS WERE SUBMITTED.
  
 16) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2012-12-12 Cont ID  
Sent By rlecky Date 2012-12-12 Time 11:35 Rev Time 0.00
Received By rlecky Date 2012-12-12 Time 11:23 Sent To  
Notes
2012-12-12 11:36:15SEE ALTERNATIVE METHODS APPROVAL FROM THE BUILDING
 OFFICIAL AND FIRE OFFICIAL FOR INDIVIDUAL ELECTRICAL
 SERVICES.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2012-11-01 Cont ID  
Sent By rlecky Date 2012-11-01 Time 11:55 Rev Time 0.00
Received By rlecky Date 2012-11-01 Time 11:21 Sent To  
Notes
2012-11-05 12:07:3812010196
 1860 N. TAMARIND AVE.
 MULTIFAMILY DWELLING
  
 PLEASE PROVIDE A RESPONSE TO THE FOLLOWING ELECTRICAL
 REVIEW COMMENTS.
  
 ADD A SMALL APPLIANCE CIRCUIT TO THE PANEL SCHEDULE FOR
 UNITS ?A? AND ?D?. NEC 210.52 (C). (THIS WAS PREVIOUSLY
 NOTED DURING THE LAST REVIEW WITH A WRITTEN RESPONSE.
 AN REVISION TO SHEET E# WAS NOT PROVIDED)
  
 THE CHANGES TO THE ELECTRICAL DESIGN FOR THE APARTMENT
 ELECTRICAL SERVICE HAS PROMPTED SOME ADDITIONAL REVIEW
 COMMENTS LISTED BELOW.
  
 A BUILDING OR OTHER STRUCTURE SERVED SHALL BE SUPPLIED
 BY ONLY ONE SERVICE. NEC 230.2
 MEANS SHALL BE PROVIDED TO DISCONNECT ALL CONDUCTORS IN
 A BUILDING. NEC 230.70
 THE SERVICE DISCONNECTING MEANS SHALL CONSIST OF NOT
 MORE THAT SIX SWITCHES. NEC 230.71
 THE TWO TO SIX DISCONNECTS AS PERMITTED SHALL BE
 GROUPED IN ONE LOCATION. NEC 230.72
  
 ROBERT LECKY
 ELECTRIC PLAN REVIEWER
 [email protected]
 561-805-6718
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2012-02-09 Cont ID  
Sent By rlecky Date 2012-02-09 Time 11:58 Rev Time 0.00
Received By rlecky Date 2012-02-09 Time 09:53 Sent To  
Notes
2012-02-09 12:00:0012010196
 1860 N. TAMARIND AVE.
 MULTIFAMILY DWELLING
  
 ADD RECEPTACLES: UNIT ?B? SECOND FLOOR AT TWO FOOT WALL
 SPACE AT CLOSET IN BEDROOM 2, UNIT ?C? SECOND FLOOR
 BALCONY INCLUDING GFCI PROTECTION, UNIT ?D? ON WALL
 SPACE NEXT TO AHU. NEC 210.52
  
 ADD A SMALL APPLIANCE CIRCUIT TO THE PANEL SCHEDULE FOR
 UNITS ?A? AND ?D?. NEC 210.52 (C)
  
 AN INTERSYSTEM BONDING STRIP IS REQUIRED AT THE MAIN
 SERVICE GROUND. NEC 250.94
  
 SERVICE FEEDER OVER CURRENT PROTECTION FOR PARALLEL 400
 MCM FEEDERS IS LIMITED TO 700 AMPERES. NEC T. 310.16,
 240 .6
  
 ROBERT LECKY
 ELECTRIC PLAN REVIEWER
 [email protected]
 561-805-6718
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2012-02-10 Cont ID  
Sent By lmartine Date 2012-02-10 Time 11:09 Rev Time 0.00
Received By lmartine Date 2012-02-10 Time 11:09 Sent To  
Notes
2012-02-10 11:11:01SEPARATE SITE DEVELOPEMENT ENGINEERING PERMIT REQUIRED.
 PLEASE CONTACT MANNY AT 561-494-1085.

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2013-01-07 Cont ID  
Sent By ddaniels Date 2013-01-07 Time 12:23 Rev Time 0.00
Received By ddaniels Date 2012-12-05 Time 08:01 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2012-10-17 Cont ID  
Sent By ddaniels Date 2012-08-17 Time 14:20 Rev Time 0.00
Received By ddaniels Date 2012-08-17 Time 14:19 Sent To  
Notes
2012-10-17 14:22:4908/17/12 PLANS REVIEWED BY FIRE **DENIED***
  
  
 DERRICK DANIELS BATTALION CHIEF / FIRE MARSHAL
 561 804-4709

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2012-01-26 Cont ID  
Sent By wjolin Date 2012-01-26 Time 15:35 Rev Time 0.00
Received By wjolin Date 2012-01-26 Time 15:35 Sent To  
Notes
2012-01-26 15:35:001860 NORTH TAMARIND AVENUE
 PERMIT #12010196
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 UPDATE THE CODE LIST TO REFERENCE THE 2010 EDITION OF
 THE FLORIDA FIRE PREVENTION CODE WHICH CONTAINS THE
 2009 EDITION OF BOTH NFPA 1 AND NFPA 101 WITH FLORIDA
 AMENDMENTS.
  
 NEW APARTMENT BUILDINGS ARE REQUIRED TO BE PROVIDED
 WITH AN AUTOMATIC SPRINKLER SYSTEM (REFERENCE CH. 30 -
 NFPA 101).
  
 ENGINEERED FIRE ALARM AND FIRE SPRINKLER CONSTRUCTION
 DOCUMENTS ARE REQUIRED FOR A GENERAL BUILDING PERMIT.
 AFTER THE BUILDING PERMIT HAS BEEN ISSUED, THE
 SUBCONTRACTORS CAN THEN SUBMIT SHOP DRAWINGS
 (CONFORMING TO THE ENGINEERED CONSTRUCTION DOCUMENTS)
 FOR A SUB-PERMIT. PER FLORIDA ADMINISTRATIVE CODE
 SECTION 61G15-32.004, FIRE PROTECTION ENGINEERING
 DOCUMENTS SHALL INCLUDE THE POINT OF SERVICE FOR THE
 WATER SUPPLY, A LIST OF APPLICABLE NFPA STANDARDS
 APPLICABLE TO THE PROJECT, CLASSIFICATION OF HAZARD
 OCCUPANCY FOR EACH ROOM OR AREA, SUPPRESSION SYSTEM
 TYPE, DESIGN DENSITIES, WATER SUPPLY DATA (FIRE PUMP
 DATA, HYDRANT FLOW TEST DATA) AND ANY PERFORMANCE BASED
 INFORMATION SUCH AS PRE-ENGINEERED SYSTEMS.
  
 SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE
 INSTALLATION OF THE FIRE SPRINKLER SYSTEM.
  
 STRUCTURES WITH LIGHT FRAME FLOOR/ROOF TRUSS
 CONSTRUCTION SHALL BE IDENTIFIED WITH A SIGN AFFIXED TO
 THE BUILDING. THE SIGN SHALL FEATURE A MALTESE CROSS
 8-INCHES WIDE AND 8-INCHES TALL AND BE OF A BRIGHT RED
 REFLECTIVE COLOR AND BEAR THE APPROPRIATE LETTER R OR
 RF PER FLORIDA STATUTE 633.027 AND FLORIDA
 ADMINISTRATIVE CODE 69A-60.0081.
  
 INDICATE THE LOCATION OF THE DESIGNATED FIRE DEPARTMENT
 ACCESS ROAD.
  
 FIRE LANE CURBS SHALL BE PAINTED AND BE MARKED WITH
 FREESTANDING SIGNS READING, ?FIRE LANE - NO PARKING BY
 ORDER OF THE FIRE DEPARTMENT.? SIGNS SHALL BE 12? X 18?
 WITH A WHITE BACKGROUND AND RED LETTERS AND SHALL BE A
 MAXIMUM OF SEVEN FEET IN HEIGHT TO THE BOTTOM OF THE
 SIGN. SIGNS SHALL BE WITHIN SIGHT OF THE TRAFFIC FLOW
 AND BE SPACED A MAXIMUM OF 60 FEET APART. FIRE
 DEPARTMENT ACCESS ROADS SHALL HAVE A SURFACE DESIGNED
 TO ACCOMMODATE FIRE APPARATUS WEIGHING AT LEAST 32
 TONS. ACCESS ROADS SHALL HAVE AN UNOBSTRUCTED WIDTH OF
 NOT LESS THAN 20 FEET AND AN UNOBSTRUCTED VERTICAL
 CLEARANCE OF NOT LESS THAN 13 FEET 6 INCHES PER
 SECTION.
  
 DEAD-END FIRE DEPARTMENT ACCESS ROADS IN EXCESS OF 150
 FEET IN LENGTH SHALL BE PROVIDED WITH APPROVED
 PROVISIONS FOR THE FIRE APPARATUS TO TURN AROUND.
  
 IN ADDITION TO THE BUILDING ADDRESS, PROVIDE THE
 BUILDING UNIT NUMBER ON EACH BUILDING. NUMBERS SHALL BE
 ATTACHED TO THE BUILDING AND BE AT LEAST SIX-INCHES IN
 HEIGHT WITH 1-INCH STROKE AND SHALL CONTRAST THE
 BACKGROUND.
  
 PROVIDE A KNOX KEY SWITCH TO ALLOW GATE ACCESS TO
 EMERGENCY RESPONDERS. KEY SWITCH CAN BE ORDERED FROM
 WWW.KNOXBOX.COM.
  
 WESLEY JOLIN
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
  

Review Stop G GAS REVIEW
Rev No 1 Status P Date 2012-10-22 Cont ID  
Sent By lwagner Date 2012-10-22 Time 12:15 Rev Time 0.00
Received By lwagner Date 2012-10-22 Time 12:04 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-11-01 Cont ID  
Sent By rlecky Date 2012-11-01 Time 14:32 Rev Time 0.00
Received By rlecky Date 2012-09-27 Time 10:59 Sent To  
Notes
2012-09-27 10:59:43INCOMING SENT TO C-09. JW

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2012-02-10 Cont ID  
Sent By lmartine Date 2012-02-10 Time 11:11 Rev Time 0.00
Received By lmartine Date 2012-01-13 Time 14:26 Sent To  
Notes
2012-01-17 14:11:31C--13

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2013-03-27 Cont ID  
Sent By jwitmer Date 2013-03-27 Time 15:50 Rev Time 0.00
Received By jwitmer Date 2013-03-27 Time 15:50 Sent To  
Notes
2013-03-27 15:52:16PR# 2013-002808-0000
 IMPACT FEES DUE: $0.00
 WPB HOUSING AUTHORITY

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2012-10-23 Cont ID  
Sent By hmoser Date 2012-10-23 Time 11:24 Rev Time 0.00
Received By hmoser Date 2012-10-23 Time 11:14 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2012-02-07 Cont ID  
Sent By hmoser Date 2012-02-07 Time 12:14 Rev Time 0.00
Received By hmoser Date 2012-02-07 Time 09:53 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2012-10-22 Cont ID  
Sent By lwagner Date 2012-10-22 Time 12:03 Rev Time 0.00
Received By lwagner Date 2012-10-22 Time 10:32 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2012-01-26 Cont ID  
Sent By lwagner Date 2012-01-26 Time 10:03 Rev Time 0.00
Received By lwagner Date 2012-01-24 Time 12:35 Sent To  
Notes
2012-01-24 13:55:59FBC 2007 PLUMBING REVIEW #1
 DENIED:
  
 1. PER FBC 2007 106.3.5.1.3 PLEASE INCLUDE HOT AND COLD
 WATER PIPING ON DRAWINGS.
  
 REVIEW BY
 LARRY WAGNER
 CHIEF PLUMBING INSPECTOR
 PHONE # 805-6692
 EMAIL [email protected]
 FAX # 805-6676
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2012-10-25 Cont ID  
Sent By avann Date 2012-10-25 Time 10:06 Rev Time 0.00
Received By ajones Date 2012-10-25 Time 10:06 Sent To  
Notes
2012-10-25 10:08:53PASSED WITH THE FOLLOWING PROVISO
  
 THE ZONING IS APPROVED SUBJECT TO THE CONDITIONS
 OUTLINED BELOW. NO CERTIFICATE OF OCCUPANCY WILL BE
 ISSUED UNTIL THESE CONDITIONS ARE MET.
  
 CONDITION 1: EACH UNIT MUST CONNECT TO TAMARIND AVENUE
 IN COMPLIANCE WITH CURRENT ZONING AND LAND DEVELOPMENT
 REGULATIONS FOR THE COLEMAN PARK OVERLAY DISTRICT AT
 THE TIME OF THE ISSUANCE OF THE CERTIFICATE OF
 OCCUPANCY.
  
 CONDITION 2: REMOVE THE FENCE CURRENTLY FRONTING THE
 PROPERTY ALONG TAMARIND AVENUE WITHIN THE BOUNDARIES OF
 THE PROPOSED DEVELOPMENT PRIOR TO ISSUANCE OF THE
 CERTIFICATE OF OCCUPANCY.
  
 ANGELLA VANN, AICP
 561-822-1441
 [email protected]
  

Review Stop Z ZONING
Rev No 1 Status P Date 2012-02-06 Cont ID  
Sent By lfranco Date 2012-02-06 Time 15:20 Rev Time 0.00
Received By ajones Date 2012-01-31 Time 08:36 Sent To  
Notes
2012-02-06 15:26:29PASSED WITH THE FOLLOWING PROVISO
  
 THE ZONING IS APPROVED SUBJECT TO THE CONDITIONS
 OUTLINED BELOW. NO CERTIFICATE OF OCCUPANCY WILL BE
 ISSUED UNTIL THESE CONDITIONS ARE MET.
  
 CONDITION 1: EACH UNIT MUST CONNECT TO TAMARIND AVENUE
 IN COMPLIANCE WITH FUTURE CITY CODES AS ENACTED AT THE
 TIME OF THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY.
  
 CONDITION 2: REMOVE THE FENCE CURRENTLY FRONTING THE
 PROPERTY ALONG TAMARIND AVENUE WITHIN THE BOUNDARIES OF
 THE PROPOSED DEVELOPMENT PRIOR TO ISSUANCE OF THE
 CERTIFICATE OF OCCUPANCY.
  
 CONDITION 3: A SEPERATE LANDSCAPE PERMIT MUST BE
 APPLIED FOR, APPROVAL AND INSTALLED PRIOR TO THE THE
 ISSUANCE OF THE CERTIFICATE OF OCCUPANCY
  
 ANGELLA VANN, AICP
 561-822-1441
 [email protected]