Plan Review Stops For Permit 12010096 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2012-02-09 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-02-09 |
Time |
11:30 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-02-09 |
Time |
06:59 |
Sent To |
|
|
Notes |
2012-02-09 11:34:18 | BUILDING PROVISO | | | | SUBMIT TWO CURRENT COPIES OF PRODUCT APPROVALS FOR THE | | MONIER LIFETILE TILE SEAL AND THE SIW ALUMNIUM OUTSWING | | DOOR W/WO SIDELITE & TRANSOM FOR APPROVAL. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2012-01-17 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-01-17 |
Time |
16:09 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-01-11 |
Time |
06:53 |
Sent To |
|
|
Notes |
2012-01-17 16:56:05 | 2007 FBC W/2009 REVISIONS | | | | DENIED BY BUILDING | | | | 1) THE STRUCTURE IS LOCATED LESS THAN 700 FEET FROM THE | | INTER-COASTAL WATERWAY WHICH MAKES THE EXPOSURE | | CATEGORY C. SEE FBC R301.2.1.4.3. | | | | 2) REVISE THE COMPONENT AND CLADDING PRESSURES ON SHEET | | ONE TO COMPLY WITH EXPOSURE CATEGORY C. SEE FBC | | R301.2.1. | | | | 3) PLEASE HAVE THE STRUCTURAL ENGINEER REVIEW THE SOIL | | REPORT FROM D & N DRILLING AND ENGINEERING, INC. TO | | INSURE THAT THE FOOTING DESIGN IS ADEQUATE. THE SOIL | | ENGINEER RECOMMENDS 24" WIDE CONTINUOUS FOOTERS AND A | | MINIMUM OF 36" FOR INDIVIDUAL FOOTERS WITH A MINIMUM | | DEPTH OF 18" BELOW THE LOWEST BORDERING FINISHED GRADE. | | | | 4) ON SHEET 4 THE DOOR BUCKS ARE SPECIFIED AS 2 X 4 | | WHICH MAY NOT BE WIDE ENOUGH TO PROVIDE FULL SUPPORT OF | | THE DOOR FRAME AS REQUIRED BY FBC R613.6.1.1. PLEASE | | REVISE. | | | | 5) FBC R308.4 REQUIRES GLAZING IN BATHROOM WINDOWS AND | | DOORS WHERE THE BOTTOM EDGE IS OF THE GLAZING IS LESS | | THAN 60 INCHES ABOVE ANY STANDING OR WALKING SURFACE TO | | BE SAFETY GLASS OR IMPACT RATED GLASS. | | | | 6) SPECIFY THE TRUSS UPLIFT PRESSURES AND PROVIDE A | | TRUSS ANCHOR SCHEDULE ON THE PLANS. SEE FBC R802.1.6.5. | | | | 7) SUBMIT TWO COMPLETE COPIES OF PRODUCT APPROVALS FOR | | THE NEW EXTERIOR DOORS, WINDOWS, STRUCTURAL MULLIONS | | AND ROOFING COVERING MATERIALS AS REQUIRED BY DCA 9N-3. | | IN ADDITION TO THE FLORIDA PRODUCT APPROVAL COVER | | SHEETS THAT WERE SUBMITTED, THE PRODUCT EVALUATIONS AND | | INSTALLATION INSTRUCTIONS ARE REQUIRED. THESE ARE | | AVAILABLE ON LINE AT | | WWW.FLORIDABUILDING.ORG/C/DEFAULT.ASPX . | | | | 8) TWO SETS OF THE PRODUCT APPROVALS ARE REQUIRED FOR | | EACH DIFFERENT TYPE OF WINDOW OR DOOR. CITY AMENDMENTS | | 106.1. | | | | 9) IF HURRICANE PANELS ARE BEING USED, SUBMIT TWO SETS | | OF PRODUCT APPROVALS, KEY PLANS AND INSTALLATION | | SCHEDULES FOR THEM. DCA RULE 9N-3 AND FBC R301.2.1.2 | | FOR INSTALLATION SCHEDULES SEE WWW.WPB.ORG/CONSTRUCTION | | /PDF/SCHEDULE_FOR_INSTALLATION.PDF. | | | | 10) SPECIFY WHICH ONE OF THE ROOF TILE ATTACHMENT | | METHODS LISTED IN THE PRODUCT APPROVAL WILL BE USED. IF | | USING A MORTAR OR ADHESIVE SET SYSTEM SUBMIT PRODUCT | | APPROVALS FOR THE PRODUCT THAT WILL BE USED. DCA RULE | | 9N-3. | | | | 11) PROVIDE A DETAIL FOR THE SISTERED 2 X 4 TRUSS TAILS | | SHOWN ON THE WALL SECTIONS ON SHEET 7. FBC R801.2 | | | | 12) THE PLANS SPECIFY A NEW 4 X 4 STEEL COLUMN AT THE | | COVERED PATIO. PROVIDE A DETAIL FOR THE 4 X 4 STEEL | | COLUMN BASE AND CAP. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2012-02-13 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2012-02-10 |
Time |
16:33 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2012-02-10 |
Time |
10:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2012-01-10 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2012-01-10 |
Time |
09:25 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2012-01-09 |
Time |
16:55 |
Sent To |
|
|
Notes |
2012-01-09 17:46:38 | 12010096 | | 6501 WASHINGTON RD. | | RESIDENTIAL ADDITION | | | | CARBON MONOXIDE ALARMS ARE REQUIRED WITHIN 10 FEET OF | | ALL EXISTING SLEEPING AREAS. FBC R313 | | MAIN ELECTRICAL DISCONNECTS MUST BE SERVICE RATED AND | | GROUPED IN ONE LOCATION. PANEL BOARDS ARE MISLABELED. | | NEC 230. | | SHOW LOCATION OF THE NEW SERVICE. NEC 215.15 | | AN INTERSYSTEM BONDING STRIP IS REQUIRED AT THE MAIN | | SERVICE GROUND NEC 250.94 | | PROVIDE A SUMMARY LOAD CALCULATION VERIFYING THE NEW | | 300 AMP SERVICE IS ADEQUATE. NEC 220.40 | | ALL NEW BRANCH CIRCUITS MUST BE PROTECTED WITH ARC | | FAULT CIRCUIT INTERRUPTERS. 2008 NEC 210.12 | | NEW RECEPTACLES MUST BE TAMPER RESISTANT NEC 406.11 | | PROVIDE A 20 AMPERE RATED BRANCH CIRCUIT FOR THE NEW | | BATHROOMS. NEC 210.11 (C) (3) | | A DISCONNECTING MEANS IS REQUIRED FOR THE AIR | | CONDITIONING UNITS. NEC 440.11 | | THE ATTIC SPACE REQUIRES A WALL-SWITCH CONTROLLED | | LIGHTING OUTLET. A LIGHTING OUTLET IS REQUIRED IN THE | | ATTIC AT OR NEAR THE EQUIPMENT REQUIRING SERVICE. NEC | | 210.70 | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2012-02-14 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2012-02-14 |
Time |
13:34 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-02-07 |
Time |
13:52 |
Sent To |
|
|
Notes |
2012-02-13 16:40:57 | NEEDS IMPACT FEE STEP RESULTED. | 2012-02-08 13:53:57 | INCOMING SENT TO R04 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2012-01-17 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-01-17 |
Time |
16:09 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-01-05 |
Time |
14:48 |
Sent To |
|
|
Notes |
2012-01-06 14:49:26 | ****************EXPEDITED******************* | | R--7 |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
P |
Date |
2012-02-14 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-02-14 |
Time |
13:52 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-02-14 |
Time |
13:52 |
Sent To |
|
|
Notes |
2012-02-14 13:53:37 | CALLED PBC IMPACT FEE DEPARTMENT AND VERIFIED THAT FEES | | HAD BEEN PAID. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2012-02-09 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-02-09 |
Time |
11:34 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-02-09 |
Time |
11:34 |
Sent To |
|
|
Notes |
2012-02-09 11:35:21 | SUBMIT A COPY OF THE PAID RECEIPT FOR THE IMPACT FEES. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2012-01-11 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-01-11 |
Time |
07:27 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-01-11 |
Time |
07:26 |
Sent To |
|
|
Notes |
2012-01-11 07:27:57 | PLAM BEACH COUNY IMPACT FEE REVIEW IS REQUIRED. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2012-02-09 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-02-09 |
Time |
08:04 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-02-09 |
Time |
08:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2012-01-12 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-01-12 |
Time |
08:23 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-01-12 |
Time |
07:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2012-02-09 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-02-09 |
Time |
08:04 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-02-09 |
Time |
08:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2012-01-11 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-01-11 |
Time |
07:26 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-01-10 |
Time |
15:57 |
Sent To |
|
|
Notes |
2012-01-11 07:26:08 | 2007 FBC W/2009 REVISIONS | | | | DENIED BY PLUMBING | | | | 1) THE SANITARY RISER DIAGRAM FOR BATH NUMBER 4 IS NOT | | CODE COMPLIANT. FBCR P3108.3 STATES THAT IN HORIZONTAL | | WET-VENT SYSTEMS, NOT MORE THAN ONE WET-VENTED FIXTURE | | DRAIN SHALL DISCHARGE UPSTREAM OF THE DRY-VENTED | | FIXTURE DRAIN CONNECTION. THE SHOWER AND WATER CLOSET | | BOTH ARE UP STREAM OF THE DRY-VENTED LAVATORY. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2012-02-13 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2012-02-13 |
Time |
15:16 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2012-02-13 |
Time |
14:43 |
Sent To |
|
|
Notes |
2012-02-13 15:19:52 | ZONING PLAN REVIEW | | ___________________________________________ | | | | DATE OF REVIEW: 02.13.2012 | | PERMIT NO.: 12010096 | | ADDRESS: 6501 WASHINGTON ROAD | | CONTRACTOR/CONTACT: STEPHEN CURY | | TELEPHONE NO.: 561.797.6007 | | SCOPE OF REVIEW: ADDITION TO EXISTING RESIDENCE. | | ___________________________________________ | | | | REVIEW STATUS: PASSED WITH PROVISOS | | ___________________________________________ | | | | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | PROVISOS: | | | | 1. AS THE VALUE OF THE PROPOSED IMPROVEMENTS EXCEEDS 50 | | PERCENT OF THE ASSESSED VALUE OF THE STRUCTURE, THE | | PROPERTY SHALL BE BROUGHT IN COMPLIANCE WITH ARTICLE | | XIV (LANDSCAPING) OF THE CITY'S ZONING AND LAND | | DEVELOPMENT REGULATIONS (ZLDRS). | | | | PRIOR TO THE FIRST INSPECTION, A LANDSCAPE PERMIT | | APPLICATION SHALL BE SUBMITTED WITH TWO (2) COPIES OF A | | LANDSCAPE PLAN, AND A CERTIFIED COST ESTIMATE. THE | | LANDSCAPE PLAN SHALL INDICATE ALL EXISTING AND PROPOSED | | TREES/SHRUBS/GROUNDCOVER/ETC AND A TABULATION TABLE | | INDICATING COMPLIANCE WITH ARTICLE XIV. | | | | IF THE EXISTING LANDSCAPING CURRENTLY CONFORMS TO THE | | MINIMUM STANDARDS OF ARTICLE XIV AND NO ADDITIONAL WORK | | IS NEEDED, SIMPLY PROVIDE A PLAN INDICATING ALL OF THE | | EXISTING LANDSCAPING, ALONG WITH A TABULATION TABLE, | | INDICATING COMPLIANCE WITH SUCH. | | ___________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | ___________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN ROACH, SENIOR PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3366 | | WEST PALM BEACH, FLORIDA 33402 | | | | PHONE: 561.822.1435 | | FAX: 561.822.1460 | | | | EMAIL: [email protected] | | | | WWW.CITYOFWPB.COM | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2012-01-13 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2012-01-13 |
Time |
16:11 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2012-01-13 |
Time |
16:11 |
Sent To |
|
|
Notes |
2012-01-13 16:15:42 | ZONING PLAN REVIEW | | ___________________________________________ | | | | DATE OF REVIEW: 01.13.2012 | | PERMIT NO.: 12010096 | | ADDRESS: 6501 WASHINGTON ROAD | | CONTRACTOR/CONTACT: STEPHEN CURY | | TELEPHONE NO.: 561.797.6007 | | SCOPE OF REVIEW: ADDITION TO EXISTING SINGLE FAMILY | | RESIDENCE. | | ___________________________________________ | | | | REVIEW STATUS: FAILED | | ___________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1. PLEASE PROVIDE THE HEIGHT OF THE PROPOSED ADDITIONS, | | AS MEASURED FROM GRADE TO THE MEAN POINT OF THE PITCHED | | ROOF. | | ___________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | ___________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN ROACH, SENIOR PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3366 | | WEST PALM BEACH, FLORIDA 33402 | | | | PHONE: 561.822.1435 | | FAX: 561.822.1460 | | | | EMAIL: [email protected] | | | | WWW.CITYOFWPB.COM | | |
|
|