Plan Review Details - Permit 11120562
Plan Review Stops For Permit 11120562 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2011-12-30 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2011-12-29 |
Time |
13:03 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2011-12-29 |
Time |
12:35 |
Sent To |
|
|
Notes |
2011-12-29 13:23:41 | BUILDING PLAN REVIEW | | PERMIT: 11120562 | | ADD: 1475 CENTREPARK BLVD # 130 | | CONT: FISHER | | TEL: (561)691-4716 | | | | 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS | | * WEST PALM BEACH AMENDMENTS | | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | ACTION: DENIED | | | | 1) PLEASE REVIEW SHEET A-2 AND A-3 FOR DISCREPANCY IN | | DOOR INDENTIFICATION. SHEET A3 DOOR MARK "B" IS | | INDICATED AS A 20 MINUTE DOOR, FBC-B TABLE 715.4 | | FOR EXIT ENCLOSURE AND EXIT PASSAGE WAYS A 1 HOUR RATED | | WAL REQUIRES A 1 HOUR RATED DOOR, THE 450 DEGREE | | TEMPERATURE RISE IS NOT REQUIRED FBC-B 715.4.4EXCEPTION | | FOR FULLY SPRINKLERED BUILDINGS. THE SAME DOOR ON SHEET | | A2 IS INDINTIFIED AS A TYPE "C" DOOR WHICH IS A BI-FOLD | | IN THE DOOR SCHEDULE. | | | | 12/29/11 A CALL IS INTO THE DESIGN PROFESSIONAL ALLEN | | BIRSE FOR RED LINING OF PLAN. | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | 12/30 /11 | | I SPOKE WITH DESIGNER ARCHITECT ALLEN BURSE AND OK TO | | RED LINE PLANS IN REGARD TO DOOR LEADING INTO THE EXIT | | PASSAGEWAY TABLE 715.4 1 HOUR/ FIRE SPRINKLERED | | BUILDING. JW |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2011-12-28 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2011-12-28 |
Time |
15:17 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2011-12-28 |
Time |
15:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2012-01-03 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2012-01-03 |
Time |
13:33 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2012-01-03 |
Time |
12:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2012-01-05 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2012-01-05 |
Time |
14:15 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2011-12-21 |
Time |
16:15 |
Sent To |
|
|
Notes |
2011-12-21 16:16:24 | ********************EXPEDITED*********************** | | B--1 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2012-01-05 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2012-01-05 |
Time |
13:58 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2012-01-05 |
Time |
13:41 |
Sent To |
|
|
Notes |
2012-01-05 13:58:19 | PASS PROVISO | | REFER TO SECTION 601.4 BALANCED RETURN AIR FOR OFFICE # | | 104 | | PLAN REVIEW BY HAROLD MOSER | | 561-805-6732 | | [email protected]. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2012-01-03 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2012-01-03 |
Time |
14:38 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2012-01-03 |
Time |
14:20 |
Sent To |
|
|
Notes |
|
|
|