Plan Review Details - Permit 11120157
Plan Review Stops For Permit 11120157 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2011-12-09 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2011-12-09 |
Time |
16:25 |
Rev Time |
0.77 |
Received By |
jwitmer |
Date |
2011-12-09 |
Time |
11:32 |
Sent To |
|
|
Notes |
2011-12-09 16:25:20 | NOTE: THIS ALTERATION DOES NOT MEET THE 50% RULE FOUND | | IN THE 2007/09 FL. EXISTING BUILDING CODE SECTION | | 703.2.2 SUPPLEMENTAL SHAFT | | AND FLOOR OPENING ENCLOSURE REQUIREMENTS, (ELEVATOR | | LOBBIES). WHEN LESS THAN 50% OF THE FLOOR PLATE IS | | BEING REMODELED THEN THE | | ELEVATOR LOBBY AND EXCEPTIONS WILL NOT BE ENFORCED. | | 2007/09 FL B C- 707.14 ELEVATOR LOBBIES | | | | BUILDING PROVISO: | | THE FILE ROOM # 1609 IS LARGER THAN 100'-0" SQ FT. | | PLEASE REVIEW FBC-B 508.2.2.1 CONSTRUCTION FOR WALLS, | | FOR INCIDENTAL USE AREAS. | | THE INCIDENTAL USE AREA SHALL BE SEPARATED FROM THE | | REMAINDER OF THE BUILDING BY CONSTRUCTION CAPABLE OF | | RESISTING THE PASSAGE OF SMOKE. | | THE PARTITIONS SHALL EXTEND FROM THE FLOOR TO THE | | UNDERSIDE OF THE FIRE-RESISTANCE-RATED FLOOR/CEILING | | ASSEMBLY OR FIRE-RESISTANCE-RATED ROOF/ | | CEILING ASSEMBLY ABOVE OR TO THE UNDERSIDE OF THE FLOOR | | OR ROOF SHEATHING, OR SUB DECK ABOVE. DOORS SHALL BE | | SELF- OR AUTOMATIC CLOSING | | UPON DETECTION OF SMOKE IN ACCORDANCE WITH SECTION | | 715.4.7.3. DOORS SHALL NOT HAVE AIR TRANSFER OPENINGS | | AND SHALL NOT BE UNDERCUT | | IN EXCESS OF THE CLEARANCE PERMITTED IN ACCORDANCE WITH | | NFPA 80. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2011-12-13 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2011-12-13 |
Time |
17:12 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2011-12-13 |
Time |
17:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2011-12-19 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2011-12-19 |
Time |
13:18 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2011-12-19 |
Time |
12:24 |
Sent To |
|
|
Notes |
2011-12-19 13:18:46 | 250 SOUTH AUSTRALIAN AVENUE - SUITE #1601 | | PERMIT #11120157 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | PROVIDE FIRE ALARM STROBE DEVICE IN FILE ROOM #1609. | | | | WESLEY JOLIN | | WEST PALM BEACH FIRE RESCUE | | FIRE & LIFE SAFETY PLAN REVIEW | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2011-12-19 |
Time |
|
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2011-12-08 |
Time |
16:44 |
Sent To |
|
|
Notes |
2011-12-08 16:44:52 | **DIGITAL** |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2011-12-08 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2011-12-08 |
Time |
16:45 |
Rev Time |
0.00 |
Received By |
rregueir |
Date |
2011-12-08 |
Time |
16:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2011-12-13 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2011-12-13 |
Time |
13:35 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2011-12-13 |
Time |
13:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2012-01-04 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2012-01-04 |
Time |
11:16 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2012-01-04 |
Time |
11:16 |
Sent To |
|
|
Notes |
2012-01-04 11:18:48 | TWO PEDDS SIGNATURE DOCUMENTS RECEIVED. ONE FOR 6 | | SIGNED AND SEALED FILES FROM KEITH SPINA, R.A., AND THE | | OTHER FOR 9 SIGNED AND SEALED FILES FROM BRADLY BROWN, | | P.E. |
|
|
|