Plan Review Stops For Permit 11110627 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2012-05-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-05-24 |
Time |
15:58 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-05-23 |
Time |
07:49 |
Sent To |
|
|
Notes |
2012-05-24 16:03:39 | THE SCOPE OF WORK WAS CHANGED FROM THE DEMOLISION AND | | REPLACEMENT OF BALCONY AND STAIRS TO REPAIRING THE | | EXISTING STAIRS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2012-04-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-04-13 |
Time |
10:03 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-04-12 |
Time |
07:21 |
Sent To |
|
|
Notes |
2012-04-13 10:02:22 | 2007 FBC W/2009 REVISIONS | | | | DENIED BY BUILDING | | | | 1) THE LIVE LOAD FOR THE BALCONY IS REQUIRED TO BE 100 | | PSF BY FBC TABLE 1607.1 (5) & (16). PLEASE REVISE SHEET | | A1 AND VERIFY DECK DESIGN FOR 100 PSF LIVE LOAD. | | | | 2) FBC 1009.4 REQUIRES STAIRWAY LANDINGS TO HAVE A | | MINIMUM DIMENSION MEASURED IN THE DIRECTION OF TRAVEL | | EQUAL TO THE WIDTH OF THE STAIRWAY. PLEASE CORRECT. | | | | 3) SHOW COMPLIANCE WITH FBC 1013.2 HEIGHT. GUARDS SHALL | | FORM A PROTECTIVE BARRIER NOT LESS THAN 42 INCHES (1067 | | MM) HIGH, MEASURED VERTICALLY ABOVE THE LEADING EDGE OF | | THE TREAD, ADJACENT WALKING SURFACE OR ADJACENT | | SEATBOARD. | | NOTE: FBC 1012.2 HEIGHT. HANDRAIL HEIGHT, MEASURED | | ABOVE STAIR TREAD NOSINGS, OR FINISH SURFACE OF RAMP | | SLOPE SHALL BE UNIFORM, NOT LESS THAN 34 INCHES (864 | | MM) AND NOT MORE THAN 38 INCHES (965 MM). EXCEPTION: | | HANDRAILS FOR STAIRS NOT REQUIRED TO BE ACCESSIBLE THAT | | FORM PART OF A GUARDRAIL MAY BE 42 INCHES (1067 MM) | | HIGH. BECAUSE THESE STAIRS ARE NOT REQUIRED TO COMPLY | | WITH ACCESSIBILITY, THE STAIR HANDRAILS CAN BE THE TOP | | OF THE GUARDS AT A HEIGHT OF 42". HOWEVER THE 36" SHOWN | | ON THE PLANS IS NOT ALLOWED. PLEASE CORRECT. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2012-01-09 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-01-09 |
Time |
15:25 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-01-09 |
Time |
10:27 |
Sent To |
|
|
Notes |
2012-01-09 10:33:39 | 2007 FBC W/2009 REVISIONS | | | | DENIED BY BUILDING | | | | 1) SPECIFY THE USE, OCCUPANCY TYPE, NUMBER OF UNITS AND | | OCCUPANT LOAD ON THE PLANS. FBC 302 | | | | 2) SPECIFY THE CONSTRUCTION TYPE OF THE BUILDING THAT | | THE STAIRS ARE SERVING ON THE PLANS. SEE FBC 602 AND | | 1009.5. | | | | 3) SPECIFY THE 2007 FLORIDA BUILDING CODE AND THE | | DESIGN PARAMETERS ON THE PLANS PER FBC 1603.1. SPECIFY | | THE FLOOR LIVE LOAD FOR THE STAIRS, LANDING AND | | BALCONY, AS WELL AS THE WIND DESIGN DATA. | | | | 4) SHOW COMPLIANCE WITH 1604.1 FOR STRUCTURAL DESIGN | | AND A CONTINUOUS LOAD PATH. | | | | 5) SUBMIT TWO COPIES OF A SURVEY THAT INDICATES THE | | DISTANCE TO OTHER STRUCTURES LOCATED ON THE PROPERTY | | AND TO THE PROPERTY LINES. SEE FBC 701. | | | | 6) SPECIFY THE STAIRWAY WIDTH ON THE PLANS. SHOW | | COMPLIANCE WITH FBC 1009.1. | | | | 7) PLEASE CLARIFY THE NUMBER OF STAIR STRINGERS ON THE | | PLANS. IT IS SPECIFIED AS 2 IN ONE PLACE AND 3 IN | | ANOTHER. | | | | 8) SPECIFY THE STAIR TREAD AND RISER DIMENSIONS ON THE | | PLANS. SHOW COMPLIANCE WITH FBC 1009.3. | | | | 9) SPECIFY THE NUMBER OF STEPS AND THE TOTAL VERTICAL | | RISE OF THE STAIRS. SEE FBC 1009.6 VERTICAL RISE. | | | | 10) SPECIFY THE STAIR LANDING DIMENSIONS ON THE PLANS, | | SHOWING THAT THEY COMPLY WITH FBC 1009.4. | | | | 11) SHOW COMPLIANCE WITH FBC 1013 FOR THE REQUIRED | | GUARDS AT THE BALCONY, LANDING AND STAIRS. SHOW | | COMPLIANCE FOR HEIGHT, OPENING LIMITATIONS AND | | STRENGTH. | | | | 12) SHOW COMPLIANCE WITH FBC 1009.10 FOR THE REQUIRED | | HANDRAILS. | | | | 13) SHOW COMPLIANCE WITH FBC 1012 FOR HEIGHT AND | | GRASPABILITY AND FBC 1607.7 FOR STRENGTH AND ATTACHMENT | | REQUIREMENTS. | | | | 14) SHOW COMPLIANCE WITH FBC 1012.5 FOR HANDRAIL | | EXTENSIONS WHERE HANDRAILS ARE NOT CONTINUOUS BETWEEN | | FLIGHTS. | | | | 15) IF REQUIRED TO BE ACCESSIBLE, HANDRAILS SHALL | | COMPLY WITH FBC 11-4.26.2. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
N |
Date |
2012-05-29 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2012-05-29 |
Time |
10:45 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2012-05-29 |
Time |
10:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2012-03-08 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2012-03-08 |
Time |
11:14 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2012-03-08 |
Time |
09:57 |
Sent To |
|
|
Notes |
2012-03-08 11:08:45 | 1021 14TH STREET | | PERMIT #11110627 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | TO ENSURE CONTINUOUS GRASPABILITY OF THE HANDRAIL, A | | MINIMUM GAP OF 1-1/2" NEEDS TO BE PROVIDED BETWEEN THE | | HANDRAIL AND THE 3" NEWEL POST DESIGNATED AS C2 ON THE | | PLANS. | | | | WESLEY JOLIN | | WEST PALM BEACH FIRE RESCUE | | FIRE & LIFE SAFETY PLAN REVIEW |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2011-12-28 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2011-12-28 |
Time |
11:22 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2011-12-28 |
Time |
10:35 |
Sent To |
|
|
Notes |
2011-12-28 11:22:31 | 1021 14TH STREET | | PERMIT #11110627 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | THE ADDRESS PROVIDED ON THE PLANS DOES NOT MATCH THE | | ADDRESS PROVIDED ON THE PERMIT APPLICATION. | | | | INDICATE WHERE THIS STAIR WILL TERMINATE IN RELATION TO | | THE ADJACENT EXTERIOR STAIR. | | | | PROVIDE SCALABLE OR DIMENSIONED STAIR, HANDRAIL AND | | GUARD DETAILS. | | | | HANDRAILS AND GUARDRAILS ARE REQUIRED ON BOTH SIDES OF | | THE STAIR. HANDRAIL ENDS SHALL BE RETURNED TO THE WALL | | OR FLOOR OR SHALL TERMINATE AT NEWEL POSTS. | | | | HANDRAIL CROSS SECTION SHALL HAVE A DIAMETER OF NOT | | LESS THAN 1.25-INCHES AND NOT MORE THAN 2-INCHES AND | | SHALL BE CONTINUOUSLY GRASPABLE. | | | | STAIRS SHALL BE SLIP RESISTANT AND HAVE A MINIMUM TREAD | | DEPTH OF 11-INCHES AND PREVENT THE ACCUMULATION OF | | WATER. | | | | WESLEY JOLIN | | WEST PALM BEACH FIRE RESCUE | | FIRE & LIFE SAFETY PLAN REVIEW | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2012-06-01 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-06-01 |
Time |
07:15 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-04-17 |
Time |
17:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2012-04-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-04-13 |
Time |
10:03 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-03-05 |
Time |
08:47 |
Sent To |
|
|
Notes |
2012-03-05 08:48:19 | SENT TO B15 SHELF FOR REVIEW. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2012-01-09 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2012-01-09 |
Time |
15:25 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2012-01-09 |
Time |
15:25 |
Sent To |
|
|
Notes |
2011-11-30 14:16:22 | IN ZONING BOX |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2012-05-01 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2012-05-01 |
Time |
10:36 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2012-05-01 |
Time |
10:36 |
Sent To |
|
|
Notes |
2012-05-01 10:36:50 | ONLY REPAIRS TO EXISTING PORCH. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2012-03-19 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2012-03-19 |
Time |
15:17 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2012-03-19 |
Time |
15:05 |
Sent To |
|
|
Notes |
2012-03-19 15:24:59 | EXISTING COVERED PORCH AND STAIR ENCROACHES INTO THE | | REQUIRED FRONT SETBACK. IF DEMOLISHED NEW PORCH AND | | STAIR SHALL MEET MINIMUM FRONT SETBACK (25'). | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | APONTE AT 561-822-1439 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2011-12-14 |
|
|
Cont ID |
|
Sent By |
astelly |
Date |
2011-12-14 |
Time |
11:55 |
Rev Time |
0.00 |
Received By |
astelly |
Date |
2011-12-14 |
Time |
11:55 |
Sent To |
|
|
Notes |
2011-12-14 11:56:54 | AMY STELLY | | PLANNING AND ZONING | | 561-822-1442 | | | | PLEASE PROVIDE A SURVEY SHOWING THE LOCATION OF THE | | SCOPE OF WORK. |
|
|