Plan Review Details - Permit 11100380
Plan Review Stops For Permit 11100380 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2012-01-23 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2012-01-23 |
Time |
16:29 |
Rev Time |
0.77 |
Received By |
jwitmer |
Date |
2012-01-23 |
Time |
16:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2011-11-21 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2011-11-21 |
Time |
16:34 |
Rev Time |
0.77 |
Received By |
jwitmer |
Date |
2011-11-21 |
Time |
16:34 |
Sent To |
|
|
Notes |
2011-11-21 16:38:26 | BUILDING PLAN REVIEW | | PERMIT: 11100380 | | ADD: 2045 REGENTS BLVD | | CONT: GADSEN PROPERTY INVESTMENT INC | | TEL: (561)294-5339 | | | | 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS | | * WEST PALM BEACH AMENDMENTS | | | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | ACTION: DENIED | | | | 1) SHEET A-1 SECTION A-A. PLEASE PROVIDE SOME | | CLARIFICATION, THE PLAN AAPPEARS TO HAVE TWO TYPES OF | | LEDGERS A 2X8 AND ALSO A 1X8 PLEASE PROVIDE WHICH IS | | THE LEDGER? | | | | 2) SHEET A-1 INDICATE THE WIND DESIGN CRITERIA AS A "B" | | EXPOSURE THIS BACK YARD BACKS UP TO A GOLF COARSE WHICH | | WILL MAKE THIS AN "C" EXPOSURE PLEASE REVIEW ASSOCIATED | | PRESSURES. FBC-B 1609.4.3 EXPOSURE C. THIS EXPOSURE | | SHALL ALSO APPLY TO ANY BUILDING LOCATED WITHIN | | EXPOSURE B-TYPE TERRAIN WHERE THE BUILDING IS WITHIN | | 100 FEET HORIZONTALLY IN ANY DIRECTION OF OPEN AREAS OF | | EXPOSURE C-TYPE TERRAIN THAT EXTENDS MORE THAN 600 FEET | | (182.9 M) AND WIDTH GREATER THAN 150 FT. IN THE UPWIND | | DIRECTION. | | | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-01-03 |
Time |
09:31 |
Sent To |
|
|
Notes |
2012-01-03 09:31:52 | TO A STELLY DESK | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2011-11-21 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2011-11-21 |
Time |
16:34 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2011-10-18 |
Time |
10:56 |
Sent To |
|
|
Notes |
2011-10-18 10:57:09 | SENT TO ZONING SHELF FOR REVIEW. JG. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2012-01-23 |
|
|
Cont ID |
|
Sent By |
astelly |
Date |
2012-01-23 |
Time |
13:11 |
Rev Time |
0.00 |
Received By |
astelly |
Date |
2012-01-23 |
Time |
13:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2011-11-02 |
|
|
Cont ID |
|
Sent By |
astelly |
Date |
2011-11-02 |
Time |
14:43 |
Rev Time |
0.00 |
Received By |
astelly |
Date |
2011-11-02 |
Time |
14:43 |
Sent To |
|
|
Notes |
2011-11-02 14:50:40 | AMY STELLY | | PLANNING AND ZONING | | 561-822-1442 | | | | THE REAR SETBACK FOR THIS PROPERTY IS 15 FEET IN | | ACCORDANCE WITH ORDINANCE 2541-92 (ORD. 2238-88 | | AMENDED). A CURSORY MEASUREMENT OF THE SETBACK AS | | PROPOSED INDICATES THAT IT IS APPROXIMATELY TEN (10) | | FEET. PLEASE ADJUST ACCORDINGLY OR APPLY FOR A VARIANCE | | FROM THE ZONING BOARD OF APPEALS TO MAINTAIN THE | | CURRENT PROPOSAL. |
|
|
|