Plan Review Details - Permit 11100164
Plan Review Stops For Permit 11100164
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2012-04-03 Cont ID  
Sent By shill Date 2012-04-03 Time 10:06 Rev Time 0.00
Received By shill Date 2012-04-03 Time 10:06 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2012-03-05 Cont ID  
Sent By shill Date 2012-03-05 Time 11:25 Rev Time 0.00
Received By shill Date 2012-03-05 Time 11:25 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2011-11-30 Cont ID  
Sent By shill Date 2011-11-30 Time 15:39 Rev Time 0.00
Received By shill Date 2011-11-30 Time 15:39 Sent To  
Notes
2011-11-30 15:48:43****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 FROM PREVIOUS LIST:
  
 1. PROVIDE INFORMATION REGARDING THE LOCATION OF THE
 ACCESSIBLE ENTRANCE(S), FBC11 4.3.2, FBC 11 4.
  
 2. FBC 11 4.3.2, SHOW ACCESSIBLE ROUTE FROM THE PUBLIC
 WAY TO THE ACCESSIBLE BUILDING ENTRANCE.
  
 3. OK
  
 4. FBC 11 4.6.2, ACCESSIBLE PARKING SPACES SERVING A
 PARTICULAR BUILDING SHALL BE LOCATED ON THE SHORTEST
 SAFELY ACCESSIBLE ROUTE OF TRAVEL FROM ADJACENT PARKING
 TO AN ACCESSIBLE ENTRANCE.
  
 2ND REVIEW, PLEASE SHOW THE ACCESSIBLE ENTRANCES.
 PROXIMITY OF THE ACCESSIBLE SPACES TO THE ENTRANCE(S)
 CANNOT BE DETERMINED. IF THERE IS MORE THAN ONE
 ADJACENT PARKING AREA, ACCESSIBLE PARKING IS TO BE
 DISPERSED.
  
 5. ADVISORY ONLY, THE FOLLOWING WEBSITE MAY BE
 INFORMATIVE:
 HTTP://WWW.ADA.GOV/RESTRIPE.PDF
  
 PLEASE NOTE THAT ADA AND THE FLORIDA BUILDING CODE
 CONSIDERS RESTRIPING "NEW CONSTRUCTION."
  
 6. THE DESIGNER TAKING RESPONSIBILITY FOR THIS DESIGN
 AND INFORMATION (AND CERTIFYING AS TO CODE COMPLIANCE)
 IS TO PROVIDE HIS/HER NAME AND SIGNATURE ON THE PLAN.
  
 2ND REVIEW, IT APPEARS THAT THE CONTRACTOR HAS REVISED
 THE ENGINEER'S SEALED PLAN. IF THE CONTRACTOR IS TAKING
 RESPONSIBILITY FOR THE DESIGN, PLEASE PROVIDE PRINTED
 NAME, SIGNATURE, AND LICENSE NUMBER ON THE PLAN.
  
 7. PLEASE REVISE PLAN TO INCLUDE TOTAL NUMBER OF
 PARKING SPACES AND NUMBER OF ACCESSIBLE SPACES, FBC
 11-4.
  
 SEE FBC 11-4.1.2(5)(A), FOUR SPACES REQUIRED, THREE
 SHOWN.
  
 PLEASE NOTE THAT THE ENGINEER IS IN CONVERSATIONS WITH
 PLANS EXAMINER IN ORDER TO RESOLVE OUTSTANDING DESIGN
 ISSUES.
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-11-16 Cont ID  
Sent By shill Date 2011-11-16 Time 12:10 Rev Time 0.00
Received By shill Date 2011-11-16 Time 12:10 Sent To  
Notes
2011-11-16 12:13:45****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. PROVIDE INFORMATION REGARDING THE LOCATION OF THE
 ACCESSIBLE ENTRANCE(S), FBC11 4.3.2, FBC 11 4.
  
 2. FBC 11 4.3.2, SHOW ACCESSIBLE ROUTE FROM THE PUBLIC
 WAY TO THE ACCESSIBLE BUILDING ENTRANCE.
  
 3. ACCESSIBLE PARKING IS TO COMPLY WITH FBC 11
 4.6.2(1), TO BE LOCATED ON AN ACCESSIBLE ROUTE NO LESS
 THAN 44 INCHES WIDE SO THAT USERS WILL NOT BE COMPELLED
 TO WALK OR WHEEL BEHIND PARKED VEHICLES. THE PLAN IS
 NOT CLEAR AS TO LOCATION OF ACCESS AISLES AND RAMPS OR
 CURB RAMPS, IF ANY.
  
 4. FBC 11 4.6.2, ACCESSIBLE PARKING SPACES SERVING A
 PARTICULAR BUILDING SHALL BE LOCATED ON THE SHORTEST
 SAFELY ACCESSIBLE ROUTE OF TRAVEL FROM ADJACENT PARKING
 TO AN ACCESSIBLE ENTRANCE.
  
 5. ADVISORY ONLY, THE FOLLOWING WEBSITE MAY BE
 INFORMATIVE:
 HTTP://WWW.ADA.GOV/RESTRIPE.PDF
  
 PLEASE NOTE THAT ADA AND THE FLORIDA BUILDING CODE
 CONSIDERS RESTRIPING "NEW CONSTRUCTION."
  
 6. THE DESIGNER TAKING RESPONSIBILITY FOR THIS DESIGN
 AND INFORMATION (AND CERTIFYING AS TO CODE COMPLIANCE)
 IS TO PROVIDE HIS/HER NAME AND SIGNATURE ON THE PLAN.
  
 7. PLEASE REVISE PLAN TO INCLUDE TOTAL NUMBER OF
 PARKING SPACES AND NUMBER OF ACCESSIBLE SPACES, FBC
 11-4.
  
  
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2011-11-07 Cont ID  
Sent By mgonzale Date 2011-11-07 Time   Rev Time 0.50
Received By mgonzale Date 2011-11-07 Time   Sent To  
Notes
2011-11-07 11:34:15CALL 811 BEFORE ANY DIGGING.
  
 NO OBJECTION.
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2012-04-03 Cont ID  
Sent By shill Date 2012-04-03 Time 10:07 Rev Time 0.00
Received By shill Date 2012-03-20 Time 11:04 Sent To  
Notes
2012-03-22 11:04:57GIVEN TO JROACH FOR REVIEW.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2012-03-22 Cont ID  
Sent By jroach Date 2012-03-20 Time 11:03 Rev Time 0.00
Received By jroach Date 2012-02-29 Time 11:26 Sent To  
Notes
2012-03-05 11:26:093/5/12 TO JR VIA AA
 (ADVISED JOHN THAT THEY WANTED TO DO WORK DURING SPRING
 BREAK)
  
  
  
2012-02-29 11:27:18SENT TO S. HILL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-11-16 Cont ID  
Sent By shill Date 2011-11-16 Time 13:08 Rev Time 0.00
Received By shill Date 2011-10-12 Time 15:07 Sent To Z
Notes
2011-11-09 11:41:4311/8 TO MISC 3
2011-10-12 15:07:50TO ZONING
  

Review Stop Z ZONING
Rev No 3 Status P Date 2012-03-27 Cont ID  
Sent By jroach Date 2012-03-27 Time 14:10 Rev Time 0.00
Received By jroach Date 2012-03-20 Time 11:05 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2012-03-20 Cont ID  
Sent By jroach Date 2012-03-20 Time 09:19 Rev Time 0.00
Received By jroach Date 2012-03-20 Time 09:19 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2011-11-01 Cont ID  
Sent By jroach Date 2011-11-01 Time 08:17 Rev Time 0.00
Received By jroach Date 2011-10-18 Time 16:52 Sent To ENG
Notes
2011-10-18 16:52:19GIVEN TO JR


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved