Plan Review Details - Permit 11080734
Plan Review Stops For Permit 11080734 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2011-09-29 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2011-09-29 |
Time |
11:41 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2011-09-29 |
Time |
11:41 |
Sent To |
|
|
Notes |
2011-09-29 11:43:08 | BUILDING REVIEW APPROVED WITH PROVISO: | | | | 1- COMPLY WITH ANCHOR SPACING AS SHOWN ON REDLINED | | INSTALLATION SCHEDULE. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2011-08-30 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2011-08-30 |
Time |
14:10 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2011-08-30 |
Time |
12:50 |
Sent To |
|
|
Notes |
2011-08-30 14:31:52 | RESIDENTIAL (R3) ACCORDION SHUTTERS, BUILDING REVIEW | | CHECKLIST. | | 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. | | | | 1- CLEARLY IDENTIFY ON ACCORDION SHUTTERS DRAWINGS | | WHICH SPECIFIC WALL ASSEMBLY (SEE PAGE 9 OF 18) IS | | GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE | | OPENING DESIGN PRESSURES, SELECTED ANCHOR TYPE AND | | SPACING, MAXIMUM SHUTTER SPAN, TYPE OF BLADE | | LIMITATIONS ETC. SEC 106.1.1 CITY AMENDMENTS TO FBC AND | | CITY POLICY FOR SHUTTERS INSTALLATION. | | | | 2- INSTALLATION SCHEDULE SUBMITTED INDICATES USING ALL | | POINTS SOLID-SET ANCHORS. TABLES ON SHEET 6 OF 18 AND | | SHEET 7 OF 18 DON'T ALLOW THE USE OF THIS CONNECTOR ON | | SOME APPLICATIONS. CLEARLY MARK ON THESE SHEETS WHICH | | ARE THE APPLICATIONS THAT APPLY USING THE ALL POINTS | | SOLID-SET ANCHOR TO VERIFY COMPLIANCE WITH THE DESIGN | | PRESSURES, SHUTTERS SPACING AND ANCHOR SPACING. SEC. | | 106.1.1 CITY AMENDMENTS TO FBC. | | | | 3- DESIGN PRESSURES CALCULATIONS DONE BY RAMMS | | ENGINEERING, INC. NEED TO HAVE ENGINEER'S ORIGINAL SEAL | | AND SIGNATURE AS REQUIRED BY CHAPTER 471 FLORIDA | | STATUTES. | | | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2011-09-29 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2011-09-29 |
Time |
11:43 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2011-09-15 |
Time |
11:07 |
Sent To |
|
|
Notes |
2011-09-15 11:07:42 | INCOMING SENT TO J. GOMEZ DESK. JW |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2011-08-30 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2011-08-30 |
Time |
13:07 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2011-08-30 |
Time |
10:33 |
Sent To |
|
|
Notes |
2011-08-30 10:33:53 | INCOMING SENT TO MISC BOX #1. JW |
|
|
|