Plan Review Details - Permit 11080705
Plan Review Stops For Permit 11080705
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2011-08-25 Cont ID  
Sent By jgomez Date 2011-08-25 Time 17:05 Rev Time 0.00
Received By jgomez Date 2011-08-25 Time 17:04 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2011-08-31 Cont ID  
Sent By rmcdouga Date 2011-08-31 Time 11:34 Rev Time 0.00
Received By rmcdouga Date 2011-08-31 Time 11:34 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2011-08-30 Cont ID  
Sent By rmcdouga Date 2011-08-30 Time 11:48 Rev Time 0.00
Received By rmcdouga Date 2011-08-30 Time 11:48 Sent To  
Notes
2011-08-30 11:50:56ELECTRICAL PLANS ARE LOCATED ON THE SHEET WITH THE
 PLUMBING PLANS WHICH WERE DENIED.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2011-08-26 Cont ID  
Sent By rmcdouga Date 2011-08-26 Time 11:26 Rev Time 0.00
Received By rmcdouga Date 2011-08-26 Time 11:26 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2011-08-31 Cont ID  
Sent By jgomez Date 2011-08-31 Time 11:27 Rev Time 0.00
Received By jgomez Date 2011-08-31 Time 11:27 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2011-08-30 Cont ID  
Sent By jgomez Date 2011-08-30 Time 11:31 Rev Time 0.00
Received By jgomez Date 2011-08-30 Time 10:21 Sent To  
Notes
2011-08-30 10:24:31EXPEDITED!!!! INCOMING SENT TO J. GOMEX DESK. JW

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-08-26 Cont ID  
Sent By rmcdouga Date 2011-08-26 Time 11:26 Rev Time 0.00
Received By rmcdouga Date 2011-08-25 Time 17:20 Sent To  
Notes
2011-08-25 17:20:31SENT TO MCDOUGAL'S DESK FOR ELECTRICAL REVIEW. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-08-25 Cont ID  
Sent By jgomez Date 2011-08-25 Time 17:19 Rev Time 0.00
Received By jgomez Date 2011-08-25 Time 14:07 Sent To  
Notes
2011-08-25 14:08:25*****************EXPEDITED*******************
 GAVE TO JULIO

Review Stop P PLUMBING
Rev No 3 Status P Date 2011-08-31 Cont ID  
Sent By jgomez Date 2011-08-31 Time 11:27 Rev Time 0.00
Received By jgomez Date 2011-08-31 Time 11:26 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2011-08-30 Cont ID  
Sent By jgomez Date 2011-08-30 Time 11:21 Rev Time 0.00
Received By jgomez Date 2011-08-30 Time 11:21 Sent To  
Notes
2011-08-30 11:31:19REVISION PLUMBING REVIEW.
 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS.
  
 1- PLUMBING RISER DIAGRAM SUBMITTED DOESN'T MATCH
 PROPOSED PLUMBING FIXTURES LAYOUT. SEE PROPOSED SECOND
 FLOOR PLAN. REVISE MASTER BATHROOM AND BATHROOM AS
 REQUIRED TO MATCH FLOOR PLAN LAYOUT AND TYPE OF FIXTURE
 SHOWN ON PROPOSED FLOOR PLAN. SEC. 106.1.1 CITY
 AMENDMENTS TO FBC.
  
 2- PLUMBING RISER DIAGRAM SUBMITTED IS MISSING THE
 LAUNDRY FLOOR DRAIN. SEC. 106.1.1 CITY AMENDMENTS.
  
 3- SPECIFY ALL PIPE SIZES. SEC. 106.1.1 CITY
 AMENDMENTS.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712

Review Stop P PLUMBING
Rev No 1 Status F Date 2011-08-25 Cont ID  
Sent By jgomez Date 2011-08-25 Time 17:05 Rev Time 0.00
Received By jgomez Date 2011-08-25 Time 17:05 Sent To  
Notes
2011-08-25 17:13:45RESIDENTIAL (R3) REVISION PLUMBING REVIEW CHECKLIST.
 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS.
  
 1- PROVIDE COMPLETE PLUMBING RISER DIAGRAM SHOWING THE
 NEW FLOOR DRAIN AND LAUNDRY. ALSO, PROVIDE PLUMBING
 RISER DIAGRAM ADDRESSING PROVISO REQUESTED ON 7/11/11.
 SEE SHEET #4 OF THE ORIGINALLY APPROVED PLANS. NEED TO
 INDICATE CHANGE OF BIDET TO LAVATORY. SEC. 106.3.5.4(9)
 OF CITY AMENDMENTS TO FBC.
 ***NOTE: PLUMBING CONTRACTOR MAY DRAW THE PLUMBING
 RISER DIAGRAM (PROVIDE NAME, SIGNATURE AND LICENSE
 NUMBER).
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561)805-6712


Account Summary | Usage Policy | Privacy Policy