Plan Review Details - Permit 11080665
Plan Review Stops For Permit 11080665
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2011-10-26 Cont ID  
Sent By jwitmer Date 2011-10-26 Time 11:36 Rev Time 0.55
Received By jwitmer Date 2011-10-26 Time 11:36 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2011-10-14 Cont ID  
Sent By jwitmer Date 2011-10-14 Time 16:02 Rev Time 0.77
Received By jwitmer Date 2011-10-14 Time 16:02 Sent To  
Notes
2011-10-14 16:11:00BUILDING PLAN REVIEW
 PERMIT: 11080665
 ADD: 1450 CENTREPARK BLVD 150
 CONT: ANDERSON-MOORE CONSTRUCTION CORP.
 TEL: (561)662-1819
  
 2007 FLORIDA BUILDING CODE-BUILDING W/ 2009 FBC
 SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS CHAPTER 1
  
 2007 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1450 CENTREPARK #165 11080820- NO FEE PERMIT FOR DEMO
 OF TENANT SEPERATION WALL AND NEW TENANT SEPERATION
 WALL, (DRYWALL SCREW INSPECTION) ONLY.
 COMMENTS FOR BOTH PERMITS 11080665 SUITE # 150 AND
 11080820 SUITE # 165 WILL APPEAR UNDER THIS REVIEW.
  
 2ND REVIEW
 ACTION: DENIED
 OCT. 14/2011
  
 1) THE LIFE SAFETY SHEET A8 INDICATES FOR BOTH SUITES
 THE COMMON PATH OF TRAVEL IS EXCEEDED. 2007 FBC-B
 1014.3 EXCEPTION# 1 DOES ALLOW FOR A 100 FOOT COMMON
 PATH OF TRAVEL FOR SPRINKLERED BUILDINGS. FOR BOTH
 SUITES THIS COMMON PATH OF TRAVEL IS EXCEEDED.THE CODE
 COMMENTARY INDICATES THE DIMENSION TO START COMMON PATH
 OF TRAVEL IS ONE FOOT FROM THE FURTHEST POINT IN THE
 TENANT SPACE. THE SECOND ISSUE # 165 THE PLANS INDICATE
 A DIAGONAL ACROSS THE TENANT SPACE. COMMON PATH OF
 TRAVEL IS TAKEN AT APPROXIMATELY 1'-0" OFF OF THE WALL
 LINE, JUSTT AS IF THE ROOM WAS FILED WITH SMOKE YOU
 WOULD CRAWL NEXT TO TTHE WALL LINE IN THE DIRECTION OF
 THE EXIT DOOR.
  
 2) SHEET A8 THE LIFE SAFETY PLAN INDICATES WITHIN SUITE
 # 150 SINCE THE COMMON PATH OF TRAVEL IS EXCEEDED, IT
 WOULD APPEAR THAT A SECOND EXIT DOOR WOULD NEED TO BE
 INCORPORATED INTO THE PLAN LAYOUT MEETING THE
 REQUIREMENT OF 1015.2.1 EXCEPTION #3. THE SECONDARY
 EXIT DOOR CURRENTLY DOE NOT MEET THIS REQUIREMENT.
  
 3-7) COMPLIED.
  
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-08-30 Cont ID  
Sent By jwitmer Date 2011-08-30 Time 15:04 Rev Time 1.10
Received By jwitmer Date 2011-08-30 Time 14:39 Sent To  
Notes
2011-08-30 16:12:13BUILDING PLAN REVIEW
 PERMIT: 11080665
 ADD: 1450 CENTREPARK BLVD 150
 CONT: ANDERSON-MOORE CONSTRUCTION CORP.
 TEL: (561)662-1819
  
 2007 FLORIDA BUILDING CODE-BUILDING W/ 2009 FBC
 SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS CHAPTER 1
  
 2007 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1450 CENTREPARK #165 11080820- NO FEE PERMIT FOR DEMO
 OF TENANT SEPERATION WALL AND NEW TENANT SEPERATION
 WALL, (DRYWALL SCREW INSPECTION) ONLY.
 COMMENTS FOR BOTH PERMITS 11080665 SUITE # 150 AND
 11080820 SUITE # 165 WILL APPEAR UNDER THIS REVIEW.
  
 1ST REVIEW
 ACTION: DENIED
  
 1) THE LIFE SAFETY SHEET A8 INDICATES FOR BOTH SUITES
 THE COMMON PATH OF TRAVEL IS EXCEEDED. 2007 FBC-B
 1014.3 EXCEPTION# 1 DOES ALLOW FOR A 100 FOOT COMMON
 PATH OF TRAVEL FOR SPRINKLERED BUILDINGS. FOR BOTH
 SUITES THIS COMMON PATH OF TRAVEL IS EXCEEDED.
  
 2) SHEET A8 THE LIFE SAFETY PLAN INDICATES WITHIN SUITE
 # 150 SINCE THE COMMON PATH OF TRAVEL IS EXCEEDED, IT
 WOULD APPEAR THAT A SECOND EXIT DOOR WOULD NEED TO BE
 INCORPORATED INTO THE PLAN LAYOUT MEETING THE
 REQUIREMENT OF 1015.2.1 EXCEPTION #3. THE SECONDARY
 EXIT DOOR CURRENTLY DOE NOT MEET THIS REQUIREMENT.
  
 3) DISCREPANCY IN PLANS PLEASE REVIEW SHEETS A4 VERSES
 A8 PRINTING ROOM # 116. SHEET A4 INDICATES A DOOR INTO
 THE EXIT ACCESS CORRIDOR, DOOR # 021 WHICH DOES NOT
 APPEAR ON SHEET A8.
  
 4) SHEET A8 INDICATES A SEPERATE TENANT SPACE ROOM
 NUMBER 115 LABELED COURIER, THESE TENANT SEPERATION
 WALLS ARE NOT INDICATED AS TENANT SEPERATION WALLS.
 2007/09 FBC-B 708.1(7).
  
 5) A4 & A8 BOTH INDICATE A NETWORK ROOM # 107, THIS
 ROOM MAY REQUIRE A 1 HOUR RATING PER NFPA 645.4(5) IF
 CONSIDERED A IT ROOM?
  
 6) A8 STORAGE ROOM # 117IS OVER 100SQ. FT. AND WILL
 NEED TO COMPLY WITH 2007/09 FBC-B FOR THE WALL TO BE
 ABLE TO RESIST THE PASSAGE OF SMOKE SEE TABLE 508.2.
 WHERE TABLE 508.2 PERMITS AN AUTOMATIC
 FIRE-EXTINGUISHING SYSTEM WITHOUT A FIRE BARRIER, THE
 INCIDENTAL USE AREA SHALL BE SEPARATED FROM THE
 REMAINDER OF THE BUILDING BY CONSTRUCTION CAPABLE OF
 RESISTING THE PASSAGE OF SMOKE. THE PARTITIONS SHALL
 EXTEND FROM THE FLOOR TO THE UNDERSIDE OF THE
 FIRE-RESISTANCE-RATED FLOOR/CEILING ASSEMBLY OR
 FIRE-RESISTANCE-RATED ROOF/CEILING ASSEMBLY ABOVE OR TO
 THE UNDERSIDE OF THE FLOOR OR ROOF SHEATHING, OR SUB
 DECK ABOVE. DOORS SHALL BE SELF- OR AUTOMATIC CLOSING
 UPON DETECTION OF SMOKE IN ACCORDANCE WITH SECTION
 715.4.7.3. DOORS SHALL NOT HAVE AIR TRANSFER OPENINGS
 AND SHALL NOT BE UNDERCUT IN EXCESS OF THE CLEARANCE
 PERMITTED IN ACCORDANCE WITH NFPA 80.
  
 7) 2007/09 FBC-B 712.6 FIRE WALLS, FIRE BARRIERS, FIRE
 PARTITIONS, SMOKE BARRIERS AND SMOKE PARTITIONS OR ANY
 OTHER WALL REQUIRED TO HAVE PROTECTED OPENINGS SHALL BE
 EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR
 STENCILING IN A MANNER ACCEPTABLE TO THE AUTHORITY
 HAVING JURISDICTION. SUCH IDENTIFICATION SHALL BE ABOVE
 ANY DECORATIVE CEILING AND IN CONCEALED SPACES.
 SUGGESTED WORDING FOR FIRE AND SMOKE BARRIERS: "FIRE
 AND SMOKE BARRIER - PROTECT ALL OPENINGS."
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2011-10-20 Cont ID  
Sent By rlecky Date 2011-10-20 Time 11:20 Rev Time 0.00
Received By rlecky Date 2011-10-20 Time 11:20 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2011-10-19 Cont ID  
Sent By rlecky Date 2011-10-19 Time 11:58 Rev Time 0.00
Received By rlecky Date 2011-10-19 Time 11:48 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2011-09-12 Cont ID  
Sent By rlecky Date 2011-09-12 Time 15:10 Rev Time 0.00
Received By rlecky Date 2011-09-12 Time 15:10 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2011-10-19 Cont ID  
Sent By wjolin Date 2011-10-19 Time 15:18 Rev Time 0.00
Received By wjolin Date 2011-10-19 Time 15:12 Sent To  
Notes
2011-10-19 15:18:001450 CENTREPARK BOULEVARD - SUITE #150
 PERMIT #11080665
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 SHEET E-3: FOR NEWLY ADDED EXIT DOOR, PROVIDE AN
 ADDITIONAL EXIT SIGN IN OPEN OFFICE #101 (JUST WEST OF
 AREA LABLED SUITE #165).
  
 WESLEY JOLIN
 WEST PALM BEACH FIRE RESCUE
 FIRE & LIFE SAFETY PLAN REVIEW

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2011-10-13 Cont ID  
Sent By wjolin Date 2011-10-13 Time 11:58 Rev Time 0.00
Received By wjolin Date 2011-10-13 Time 10:00 Sent To B
Notes
2011-10-13 11:58:151450 CENTREPARK BOULEVARD - SUITE #150
 PERMIT #11080665
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 SHEET A-8: THE COMMON PATH OF TRAVEL FOR SUITE #165
 STILL EXCEEDS 100 FEET AS THE TWO SUITE ENTRY DOORS ARE
 NOT LOCATED FAR ENOUGH APART TO CONSTITUTE SEPARATE
 EXITS. NO FURNITURE OR EQUIPMENT HAS BEEN SHOWN FOR
 SUITE #165 WHICH MAY ALSO INCREASE THE COMMON PATH OF
 TRAVEL DISTANCE.
  
 SHEET E-2: NO FIRE ALARM NOTIFICATION APPLIANCE
 PROVIDED IN CONFERENCE ROOM #103 OF SUITE #150.
  
 WESLEY JOLIN
 WEST PALM BEACH FIRE RESCUE
 FIRE & LIFE SAFETY PLAN REVIEW

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2011-08-30 Cont ID  
Sent By wjolin Date 2011-08-30 Time 09:49 Rev Time 0.00
Received By wjolin Date 2011-08-29 Time 14:34 Sent To  
Notes
2011-08-30 09:49:091450 CENTREPARK BOULEVARD - SUITE #150
 PERMIT #11080665
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 EACH NEW SMOKE OR FIRE-RATED WALL/PARTITION SHALL BE
 PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING READING
 FIRE/SMOKE BARRIER - PROTECT ALL OPENINGS. CHARACTERS
 SHALL BE AT LEAST 4-INCHES IN HEIGHT AND HALF-INCH IN
 STROKE. IDENTIFICATION SHALL BE SPACED NOT MORE THAN 15
 FEET ON CENTER.
  
 PENETRATIONS THROUGH A FIRE-RATED WALL ASSEMBLY SHALL
 BE PROTECTED BY A FIRESTOP SYSTEM OR DEVICE.
  
 PROVIDE TACTILE SIGNAGE AT REQUIRED EXIT DOORS WITH
 EXIT SIGNS.
  
 SHEET A-8: THE COMMON PATH OF TRAVEL INDICATED ON THE
 PLAN EXCEEDS 100 FEET OF LENGTH.
  
 SHEET A-8: TRAVEL DISTANCE TO EXTINGUISHERS EXCEED 75
 FEET.
  
 SHEET E-2: CONFERENCE ROOM #103 AND RECEPTION #101
 EQUIPPED WITH CARD READERS PREVENTING OCCUPANTS FREE
 EGRESS TO A SECONDARY EXIT.
  
 SHEET E-2: EXIT ACCESS CORRIDOR IN SUITE #150 EQUIPPED
 WITH CARD READER ON EGRESS SIDE OF EXTERIOR EXIT DOOR.
  
 SHEET E-2: FOUR FIRE ALARM HORN-STROBE DEVICES SHOWN.
 IT MAY BE DIFFICULT TO MEET THE AUDIBILITY REQUIREMENTS
 OF NFPA 72 WITH ONLY FOUR AUDIBLE DEVICES.
  
 SHEET E-3: NO EXIT SIGNAGE PROVIDED FOR SOUTH OFFICE
 SPACE IN SUITE #165.
  
 WESLEY JOLIN
 WEST PALM BEACH FIRE RESCUE
 FIRE & LIFE SAFETY PLAN REVIEW
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2011-10-26 Cont ID  
Sent By jwitmer Date 2011-10-26 Time 12:06 Rev Time 0.00
Received By jwitmer Date 2011-10-19 Time 16:29 Sent To  
Notes
2011-10-19 16:30:02B--23

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-10-26 Cont ID  
Sent By rlecky Date 2011-10-19 Time 12:08 Rev Time 0.00
Received By jwitmer Date 2011-10-05 Time 15:20 Sent To  
Notes
2011-10-19 12:06:03B23
2011-10-05 15:20:24IN FIRE BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-09-21 Cont ID  
Sent By hmoser Date 2011-09-21 Time 10:55 Rev Time 0.00
Received By hmoser Date 2011-08-26 Time 14:25 Sent To  
Notes
2011-08-26 14:26:19SENT TO B12 SHELF FOR REVIEW BY ALL TRADES. JG.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2011-09-21 Cont ID  
Sent By hmoser Date 2011-09-21 Time 10:55 Rev Time 0.00
Received By hmoser Date 2011-09-21 Time 10:20 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2011-10-26 Cont ID  
Sent By lwagner Date 2011-10-26 Time 12:00 Rev Time 0.00
Received By lwagner Date 2011-10-26 Time 12:00 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2011-08-29 Cont ID  
Sent By lwagner Date 2011-08-29 Time 11:09 Rev Time 0.00
Received By lwagner Date 2011-08-29 Time 10:20 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2011-09-05 Cont ID  
Sent By jroach Date 2011-09-05 Time 17:06 Rev Time 0.00
Received By jroach Date 2011-09-05 Time 17:06 Sent To  
Notes
***NONE***