Plan Review Details - Permit 11080428
Plan Review Stops For Permit 11080428 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2012-04-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-04-05 |
Time |
14:30 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-04-05 |
Time |
14:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2011-10-04 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2011-10-04 |
Time |
09:37 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2011-09-30 |
Time |
12:18 |
Sent To |
|
|
Notes |
2011-10-04 09:51:26 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2007 | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | 1. DUE TO A DISCREPANCY ON THE PERMIT APPLICATION | | (CONFLICTING NAMES), PLEASE PROVIDE A COPY OF THE | | BUSINESS TAX RECEIPT AND INSURANCE CERTIFICATE FOR | | FLORIDA WINDOW CO LLC OR ALL INFORMATION (LICENSE, TAX | | RECEIPT, INSURANCE CERTIFICATE W/C & GL) FOR FLORIDA | | WINDOW & DOOR. PLEASE ESTABLISH UNDER WHAT NAME THIS | | COMPANY IS OFFERING CONTRACTING SERVICES AND PROVIDE | | ALL APPROPRIATE PAPERWORK SUCH AS DBA, FICTITIOUS NAME, | | ETC. | | | | 2ND REVIEW, PLEASE SUBMIT A PERMIT APPLICATION UNDER | | THE CONTRACTOR'S LEGAL NAME. TWO COMPANY NAMES ARE NOW | | ON THE PERMIT APPLICATION SUBMITTED BUT IT DOES NOT | | APPEAR THAT ONE OF THE COMPANIES HAS A LICENSE. | | | | 2. CONTRACTOR HAS 13 EXPIRED PERMITS IN OUR SYSTEM. | | PLEASE ADDRESS. SEE FBC105.3.2. | | | | 2ND REVIEW, PLEASE EITHER SUBMIT APPLICATION FOR | | "REISSUE" OF EXPIRED PERMITS (DOCUMENTS REQUIRED IF | | EXPIRED OVER 1 YEAR) OR SUBMIT LETTERS OF CANCELLATION | | IF THE WORK WAS NOT DONE. | | | | 3. ADDRESSED | | | | 4. ADDRESSED | | | | 5. FOR THE SHUTTER, COMPLETE THE SAMPLE INSTALLATION | | SCHEDULE OR PROVIDE ALL INFORMATION TO SHOW CODE | | COMPLIANCE IN ANOTHER FORMAT, FBC*106, FBC R301, | | FBC1609. TWO SETS REQUIRED. THIS FORM IS AVAILABLE IN | | THE LOBBY OR ON THE INTERNET AT | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ | | INSTALLATION.PDF | | | | 2ND REVIEW, NOT ADDRESSED. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2011-08-17 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2011-08-17 |
Time |
09:04 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2011-08-16 |
Time |
15:39 |
Sent To |
|
|
Notes |
2011-08-17 09:44:05 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2007 | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | 1. DUE TO A DISCREPANCY ON THE PERMIT APPLICATION | | (CONFLICTING NAMES), PLEASE PROVIDE A COPY OF THE | | BUSINESS TAX RECEIPT AND INSURANCE CERTIFICATE FOR | | FLORIDA WINDOW CO LLC OR ALL INFORMATION (LICENSE, TAX | | RECEIPT, INSURANCE CERTIFICATE W/C & GL) FOR FLORIDA | | WINDOW & DOOR. PLEASE ESTABLISH UNDER WHAT NAME THIS | | COMPANY IS OFFERING CONTRACTING SERVICES AND PROVIDE | | ALL APPROPRIATE PAPERWORK SUCH AS DBA, FICTITIOUS NAME, | | ETC. | | | | 2. CONTRACTOR HAS 13 EXPIRED PERMITS IN OUR SYSTEM. | | PLEASE ADDRESS. SEE FBC105.3.2. | | | | 3. PLEASE REVISE THE FLOOR PLAN TO INCLUDE ROOM | | DESIGNATIONS. NOTE TYPE OF EXISTING WINDOWS FOR | | BEDROOMS, FBC R310, FBC EB 604.1 | | | | 4. CLARIFY SCOPE OF WORK. APPLICATION INCLUDES A SWING | | DOOR, SLIDING GLASS DOOR, AND A MULTIPANEL DOOR. PLAN | | DOES NOT SHOW A SWING DOOR, SHOWS TWO SGDS (NO | | MULTIPANEL DOOR), AND A CLEAR PANEL SHUTTER. | | | | 5. FOR THE SHUTTER, COMPLETE THE SAMPLE INSTALLATION | | SCHEDULE OR PROVIDE ALL INFORMATION TO SHOW CODE | | COMPLIANCE IN ANOTHER FORMAT, FBC*106, FBC R301, | | FBC1609. TWO SETS REQUIRED. THIS FORM IS AVAILABLE IN | | THE LOBBY OR ON THE INTERNET AT | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_ | | INSTALLATION.PDF | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2012-04-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-04-05 |
Time |
14:30 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-03-26 |
Time |
10:36 |
Sent To |
|
|
Notes |
2012-03-27 10:37:17 | SENT TO SAMANTHA'S DESK FOR REVIEW. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2011-10-04 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2011-10-04 |
Time |
09:51 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2011-09-15 |
Time |
09:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2011-08-17 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2011-08-17 |
Time |
09:44 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2011-08-16 |
Time |
14:01 |
Sent To |
|
|
Notes |
2011-08-16 14:02:02 | TO MISC 1 BOX |
|
|
|
Account Summary | Usage Policy | Privacy Policy