Plan Review Details - Permit 11070631
Plan Review Stops For Permit 11070631
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2011-08-12 Cont ID  
Sent By lmartine Date 2011-08-12 Time 15:14 Rev Time 0.00
Received By lmartine Date 2011-08-11 Time 14:22 Sent To  
Notes
2011-08-12 15:15:16SEE JIM WITMER SIGNATURE ON PLANS DATED 8/11/11.
2011-08-11 14:22:45BUILDING PLAN REVIEW
 PERMIT: 11070631
 ADD: 3990 N FLAGLER
 CONT: BENCHMARK III CORP.
 TEL: (561)722-5095
  
 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
  
 1) 105.13. SPECIAL FOUNDATION PERMIT
 WHEN APPLICATION FOR A PERMIT TO ERECT OR ENLARGE A
 BUILDING HAS BEEN FILED, & PENDING ISSUANCE OF SUCH
 PERMIT, THE BUILDING OFFICIAL MAY, AT HIS/ HER
 DISCRETION, ISSUE A SPECIAL PERMIT FOR THE FOUNDATION
 ONLY, UPON WRITTEN REQUEST OF THE OWNER AND CONTRACTOR.
 THE HOLDER OF SUCH A SPECIAL PERMIT IS PROCEEDING AT
 HIS OR HER OWN RISK AND WITHOUT ASSURANCE THAT A PERMIT
 FOR THE REMAINDER OF THE WORK WILL BE GRANTED AND THAT
 CORRECTIONS WILL NOT BE REQUIRED IN ORDER TO MEET THE
 PROVISIONS OF THE TECHNICAL CODE.
  
 2) COUNTY IMPACT FEE OFFICE HAS AGREED TO ALLOW THE
 IMPACT FEE ASSESSMENT TO BE PAID AT TIME OF PERMIT FOR
 THE BUILDING BEFORE ISSUANCE OF THE BUILDING PERMIT.
  
 3) 2007 FBC-B 1802.4-6 QUESTIONABLE SOILS. AT THIS TIME
 NO SOILS REPORTS HAVE BEEN TURNED IN. IT WILL BE
 REQUIRED AT TIME OF THE FOUNDATION INSPECTION THE
 INSPECTOR TO RECEIVE A SIGNED & SEALED ORIGINAL REPORT
 FROM THE STUDY COMPLETED BY DUNKLEBERGER ENGINEERING &
 TESTING, INC.
  
 4) FBC BUILDING 3110.1.2 / CITY OF WPB CODE OF
 ORDINANCES SECTION 94-546. STRUCTURE IS LOCATED IN AN
 "A" FLOOD ZONE. A FLOOD ELEVATION CERTIFICATE WILL BE
 REQUIRED.
  
 FEMA FORM OMB NO. 1660-0008 EXPIRES: MARCH 31, 2012.
 FEMA'S NEW ELEVATION CERTIFICATE (EC) WAS APPROVED FOR
 USE, EFFECTIVE MARCH 16, 2009, THROUGH MARCH 31, 2012.
 THE NEW EC WILL BE PHASED IN ON A VOLUNTARY BASIS UNTIL
 MARCH 31, 2010. ALTHOUGH THE OLD VERSION OF THE FORM IS
 NO LONGER AVAILABLE FOR DISTRIBUTION, EXISTING COPIES
 MAY BE USED UNTIL MARCH 31, 2010. ELEVATIONS CERTIFIED
 ON OR AFTER APRIL 1, 2010, MUST BE SUBMITTED ON THE NEW
 FORM.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-08-11 Cont ID  
Sent By jwitmer Date 2011-08-01 Time 15:02 Rev Time 0.77
Received By jwitmer Date 2011-08-01 Time 08:13 Sent To  
Notes
2011-08-01 08:24:56BUILDING PLAN REVIEW
 PERMIT: 11070631
 ADD: 4200 N FLAGLER
 CONT: BENCHMARK III CORP.
 TEL: (561)722-5095
  
 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) THIS PLAN IS FOR A NEW BUILDING PLEASE PROVIDE SOILS
 REPORT FOR THE SAFE MINIMUM SOIL BEARING VALUES.
 1802.2.1 QUESTIONABLE SOIL. WHERE THE SAFE-SUSTAINING
 POWER OF THE SOIL IS IN DOUBT, OR WHERE A LOAD-BEARING
 VALUE SUPERIOR TO THAT SPECIFIED IN
 THIS CODE IS CLAIMED, THE BUILDING OFFICIAL SHALL
 REQUIRE THAT THE NECESSARY INVESTIGATION BE MADE. SUCH
 INVESTIGATION SHALL COMPLY WITH THE PROVISIONS
 OF SECTIONS 1802.4 THROUGH 1802.6 .
  
 2) THIS BUILDING IS IN A A- 5 FLOOD ZONE. THE BASE
 FLOOD ELEVATION FOR FINISH FLOOR IS 7.5 NGVD. SHEET
 AS-101 INDICATES A FINISH FLOOR ELEVATION OF 100.00'
 BUT THERE IS NO REFERENCE TO WHAT
 100.00' IS EQUAL TO?
  
 3) THIS BUILDING (FOOTING) ALSO DOES NOT INDICATE TYPE
 OF OCCUPANCY AND MINIMUM BUILDING TYPE. 2007/09 FBC-B
 503. THIS INFORMATION IS REQUIRED TO VERIFY THE TYPE
 AND SIZE OF BUILDING IS DESIGN PER TABLE 503.
  
 4) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2011-08-12 Cont ID  
Sent By rlecky Date 2011-08-12 Time 11:36 Rev Time 0.00
Received By rlecky Date 2011-08-12 Time 11:36 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2011-08-02 Cont ID  
Sent By rlecky Date 2011-08-02 Time 11:45 Rev Time 0.00
Received By rlecky Date 2011-08-02 Time 11:13 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2011-08-04 Cont ID  
Sent By mgonzale Date 2011-08-04 Time   Rev Time 1.00
Received By mgonzale Date 2011-08-04 Time   Sent To  
Notes
2011-08-04 09:25:22PASSED - NO CONFLICT WITH ANY CITY OF WPB PUBLIC
 UTILITY
  
 MANUEL JULIAN GONZALEZ
 CSD ENGINEERING REVIEW
 401 CLEMATIS STREET,
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 MOBILE: (561) 644-7301
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2011-08-02 Cont ID  
Sent By wjolin Date 2011-08-02 Time 14:02 Rev Time 0.00
Received By wjolin Date 2011-08-02 Time 13:25 Sent To  
Notes
2011-08-02 14:02:283990 NORTH FLAGLER DRIVE
 PERMIT #11070631
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 PROVIDE BUILDING ADDRESS VISIBLE FROM THE STREET.
 NUMBERS SHALL BE AT LEAST SIX-INCHES IN HEIGHT AND
 SHALL CONTRAST THE BACKGROUND (REFERENCE: SECTION
 10.12.1.2 OF THE FLORIDA FIRE PREVENTION CODE ? NFPA
 1).
  
 STRUCTURES WITH LIGHT FRAME FLOOR/ROOF TRUSS
 CONSTRUCTION SHALL BE IDENTIFIED WITH A SIGN AFFIXED TO
 THE BUILDING. THE SIGN SHALL FEATURE A MALTESE CROSS
 8-INCHES WIDE AND 8-INCHES TALL AND BE OF A BRIGHT RED
 REFLECTIVE COLOR AND BEAR THE APPROPRIATE LETTER R/F/RF
 DESIGNATION PER FLORIDA STATUTE 633.027 AND FLORIDA
 ADMINISTRATIVE CODE 69A-60.0081.
  
 PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS
 SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE
 TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL
 DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET.
  
 PROVIDE TACTILE SIGNAGE AT ALL REQUIRED EXIT DOORS WITH
 EXIT SIGNS.
  
 INDICATE WHAT COMMODITIES/MATERIALS WILL BE STORED, HOW
 MUCH WILL BE STORED, AND THE STORAGE CONFIGURATIONS.
  
 WESLEY JOLIN
 WEST PALM BEACH FIRE RESCUE
 FIRE & LIFE SAFETY PLAN REVIEW
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-08-12 Cont ID  
Sent By lmartine Date 2011-08-04 Time 15:12 Rev Time 0.00
Received By lmartine Date 2011-07-26 Time 08:42 Sent To  
Notes
2011-07-27 08:42:59C14

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2011-08-11 Cont ID  
Sent By jwitmer Date 2011-08-11 Time 14:21 Rev Time 0.00
Received By jwitmer Date 2011-08-01 Time 08:25 Sent To  
Notes
2011-08-01 08:26:03BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 8/11/11 COUNTY HAS AGREED THE IMPACT FEES CAN BE
 ASSESSED AGAINST THE BUILDING PERMIT BEFORE ISSUANCE.
 JW
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2011-08-02 Cont ID  
Sent By hmoser Date 2011-08-02 Time 10:21 Rev Time 0.00
Received By hmoser Date 2011-08-02 Time 10:21 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2011-08-12 Cont ID  
Sent By lwagner Date 2011-08-12 Time 14:35 Rev Time 0.00
Received By lwagner Date 2011-08-12 Time 14:34 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2011-08-02 Cont ID  
Sent By lwagner Date 2011-08-02 Time 10:12 Rev Time 0.00
Received By lwagner Date 2011-08-02 Time 08:52 Sent To  
Notes
2011-08-02 10:10:51FBC PLUMBING 2007 REVIEW #1
 DENIED:
  
 1. THIS BUILDING DOES NOT INDICATE TYPE OF OCCUPANCY
 AND NUMBER OF OCCUPANTS.
 403.1 MINIMUM NUMBER OF FIXTURES. PLUMBING FIXTURES
 SHALL BE PROVIDED FOR THE TYPE OF OCCUPANCY AND IN THE
 MINIMUM NUMBER SHOWN IN TABLE 403.1. TYPES OF
 OCCUPANCIES NOT SHOWN IN TABLE 403.1 SHALL BE
 CONSIDERED INDIVIDUALLY BY THE CODE OFFICIAL. THE
 NUMBER OF OCCUPANTS SHALL BE DETERMINED BY THE FLORIDA
 BUILDING CODE, BUILDING. OCCUPANCY CLASSIFICATION SHALL
 BE DETERMINED IN ACCORDANCE WITH THE FLORIDA BUILDING
 CODE, BUILDING.
  
 ****NOTE****
 STORAGE OCCUPANCIES REQUIRE A DRINKING FOUNTAIN AND
 SERVICE SINK.
  
 REVIEW BY
 LARRY WAGNER
 CHIEF PLUMBING INSPECTOR
 PHONE # 805-6692
 EMAIL [email protected]
 FAX # 805-6676
  

Review Stop Z ZONING
Rev No 1 Status P Date 2011-08-04 Cont ID  
Sent By jroach Date 2011-08-04 Time 11:11 Rev Time 0.00
Received By jroach Date 2011-08-04 Time 11:11 Sent To  
Notes
2011-08-04 11:11:59ZONING PLAN REVIEW
 ___________________________________________
  
 DATE OF REVIEW: 08.04.2011
 PERMIT NO.: 11070631
 ADDRESS: 3990 NORTH FLAGLER DRIVE
 CONTRACTOR/CONTACT: GREGORY HALE
 TELEPHONE NO.: 772.320.0206
 SCOPE OF REVIEW: FOUNDATION FOR MAINTENANCE BUILDING.
 ___________________________________________
  
 REVIEW STATUS: PASSED WITH PROVISOS
 ___________________________________________
  
 THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING
 PROVISOS:
  
 1. PERMIT ISSUED FOR FOUNDATION WORK ONLY! AS THE
 REQUIRED MAJOR AMENDMENT TO THE RYBOVICH CMPD HAS NOT
 BEEN APPROVED BY THE CITY COMMISSION, WORK MAY PROCEED
 AT YOUR OWN RISK! ANY MODIFICATIONS, OR A DENIAL, BY
 THE CITY COMMISSION MAY REQUIRE THE REMOVAL OF ANY
 IMPROVEMENTS INSTALLED AS PART OF THIS PERMIT.
 ___________________________________________
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 ___________________________________________
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN ROACH, SENIOR PLANNER
 CITY OF WEST PALM BEACH
 PLANNING AND ZONING DEPARTMENT
 401 CLEMATIS STREET - P.O. BOX 3366
 WEST PALM BEACH, FLORIDA 33402
  
 PHONE: 561.822.1435
 FAX: 561.822.1460
  
 EMAIL: [email protected]
  
 WWW.CITYOFWPB.COM


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved