Plan Review Details - Permit 11070619
Plan Review Stops For Permit 11070619 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2012-03-01 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2012-03-01 |
Time |
16:39 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2012-03-01 |
Time |
15:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2012-02-01 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2012-02-01 |
Time |
15:01 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2012-02-01 |
Time |
15:01 |
Sent To |
|
|
Notes |
2012-02-01 16:06:38 | BUILDING PLAN REVIEW | | PERMIT: 11070619 | | ADD: 2321 OKEECHOBEE BLVD, BLDG# 3 | | CONT: NORTH AMERICAN AUTOMOTIVE SERVICES | | TEL: (630)352-8126 | | | | 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS | | * WEST PALM BEACH AMENDMENTS | | 2007 FLORIDA EXISTING BUILDING CODE W/ 2009 FBC | | SUPPLEMENTS | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 3RD REVIEW | | ACTION: DENIED | | | | 1) SHEET 3-A1.0 INDICATES A WALL SECTION A, THERE IS NO | | CUT SECTION INDICATING WHERE THIS WALL IS TO BE | | INSTALLED. | | | | 2) SHEET 3-A1.0 SAME WALL SECTION INDICATES THIS WALL | | SECTION IS TO BE A 2 HOUR RATED WALL BUT NO LISTING IS | | PROVIDED FOR THIS WALL . | | | | 3) SHEET 3-A1.0 WALL SECTION 1 NEW STORFRONT ALSO | | DOESN'T INDICATE WHERE THIS WALL SECTION WILL BE | | INSTALLED? | | | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2011-10-05 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2011-10-05 |
Time |
11:28 |
Rev Time |
0.50 |
Received By |
jwitmer |
Date |
2011-10-05 |
Time |
11:23 |
Sent To |
|
|
Notes |
2011-10-05 11:25:34 | BUILDING APPROVED WITH EXCEPTION! | | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO | | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO | | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE | | ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE | | ADDITIONAL REVIEWS WITH ASSOCIATED FEES. | | | | BUILDING PLAN REVIEW | | PERMIT: 11070619 | | ADD: 2321 OKEECHOBEE BLVD, BLDG# 3 | | CONT: NORTH AMERICAN AUTOMOTIVE SERVICES | | TEL: (630)352-8126 | | | | 1) PRE-MANUFACTURERED PAINT SPRAY BOOTH AND SYSTEMS ARE | | TO BE UNDER A SEPARATE PERMIT | | WITH ASSOCIATED REVIEWS AND FEES. | | | | 2) NOA: 07-1018.10 | | DURO-LAST SINGLE PLY PVC ROOFING SYSTEM OVER CONCRETE | | DECK, | | PAGE 5, DECK TYPE 31 CONCRETE DECK INSULATED -217.5 | | LIMITATION # 9 | | | | NOA 09-0219.09 | | JOHN MANVILLE ROOF INSULATION BOARD | | ROOF ASSEMBLIES ARE APPROVED UNDER SPECIFIC ROOF | | COVER?S PRODUCT NOA. | | | | NOA 07-1018.14 | | DURO-LAST SINGLE PLY PVC ROOFING SYSTEM OVER WOOD DECK | | THE INDIVIDUAL SUB-SYSTEMS ARE NOT IDENTIFIED, ROOFING | | CONTRACTOR WILL NEED TO | | IDENTIFY SUB-SYSTEM AND IF LIMITATION # 7 APPLIES THEN | | ENHANCED FASTENING IN ZONES | | 2 & 3 WILL NEED TO BE CALCULATED AND PREPARED BY EITHER | | A FLORIDA REGISTERED PROFESSIONAL ENGINEER OR | | REGISTERED ARCHITECT. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2011-08-09 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2011-08-09 |
Time |
15:29 |
Rev Time |
0.55 |
Received By |
jwitmer |
Date |
2011-08-09 |
Time |
15:29 |
Sent To |
|
|
Notes |
2011-08-09 15:42:11 | BUILDING PLAN REVIEW | | PERMIT: 11070619 | | ADD: 2321 OKEECHOBEE BLVD, BLDG# 3 | | CONT: NORTH AMERICAN AUTOMOTIVE SERVICES | | TEL: (630)352-8126 | | | | 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS | | * WEST PALM BEACH AMENDMENTS | | 2007 FLORIDA EXISTING BUILDING CODE W/ 2009 FBC | | SUPPLEMENTS | | 2007 EXISTING BUILDING CODE LEVEL II 701.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | ACTION: DENIED | | | | 1) 3-A1.0 RESTROOMS SHOWN ON PLANS INDICATE A RESTROOM | | THAT IS NOT ACCESSIBLE 20% OF THE VALUE OF THE PERMITED | | WORK OR $12,000.00 IS TO GO INTO ACCESSIBLE | | IMPROVEMENTS WITHIN THE BUILDING, THE MONIES ARE TO BE | | SPENT IN THIS ORDER. | | | | 2007/09 FBC-B 11-4.1.6(2) | | ALTERATIONS TO AN AREA CONTAINING A PRIMARY FUNCTION. | | IN ADDITION TO THE REQUIREMENTS OF SECTION 11-4.1.6(1), | | AN ALTERATION THAT AFFECTS OR COULD AFFECT THE | | USABILITY OF OR ACCESS TO AN AREA CONTAINING A PRIMARY | | FUNCTION SHALL BE MADE SO AS TO ENSURE THAT, TO THE | | MAXIMUM EXTENT FEASIBLE, THE PATH OF TRAVEL TO THE | | ALTERED AREA AND THE RESTROOMS, TELEPHONES, AND | | DRINKING FOUNTAINS SERVING THE ALTERED AREA, ARE | | READILY ACCESSIBLE TO AND USABLE BY INDIVIDUALS WITH | | DISABILITIES, UNLESS SUCH ALTERATIONS ARE | | DISPROPORTIONATE TO THE OVERALL ALTERATIONS TIN TERMS | | OF COST AND SCOPE. | | | | ALTERATIONS MADE TO PROVIDE AN ACCESSIBLE PATH OF | | TRAVEL TO ALTERED AREAS SHALL BE DEEMED | | DISPROPORTIONATE TO THE OVERALL ALTERATION WHEN THE | | COST EXCEEDS 20 PERCENT OF THE COST OF THE ALTERATION | | TO THE PRIMARY FUNCTION AREA. | | | | DUTY TO PROVIDE ACCESSIBLE FEATURES IN THE EVENT OF | | DISPROPORTIONALITY. | | | | (1) WHEN THE COST OF ALTERATIONS NECESSARY TO MAKE THE | | PATH OF TRAVEL TO THE ALTERED AREA FULLY ACCESSIBLE IS | | DISPROPORTIONATE TO THE COST OF THE OVERALL ALTERATION, | | THE PATH OF TRAVEL SHALL BE MADE ACCESSIBLE TO THE | | EXTENT THAT IT CAN BE MADE ACCESSIBLE WITHOUT INCURRING | | DISPROPORTIONATE COSTS. | | | | (2)(A) IN CHOOSING WHICH ACCESSIBLE ELEMENTS TO | | PROVIDE, PRIORITY SHOULD BE GIVEN TO THOSE ELEMENTS | | THAT WILL PROVIDE THE GREATEST ACCESS, IN THE FOLLOWING | | ORDER: | | | | | | (I) AN ACCESSIBLE ENTRANCE; | | (II) AN ACCESSIBLE ROUTE TO THE ALTERED AREA: | | (III) AT LEAST ONE ACCESSIBLE RESTROOM FOR EACH SEX OR | | A SINGLE UNISEX RESTROOM: | | (IV) ACCESSIBLE TELEPHONES; | | (V) ACCESSIBLE DRINKING FOUNTAINS; AND | | (VI) WHEN POSSIBLE, ADDITIONAL ACCESSIBLE ELEMENTS SUCH | | AS PARKING, STORAGE, AND ALARMS. | | | | 2) SHEET 3A-6.0 INDICATES NEW BUILT UP ROOF WITH | | INSULATION DETAIL 2 INDICATES THE USE OF ? INCH OF | | RIGID COVER BOARD AND 2 INCHES OF POLYISO INSULATION. | | THE NOA 10-1018.02 PAGE 4 INDICATES THE INSULATION TO | | HAVE CURRENT NOA?S. | | | | END OF REVIEW | | | | JAMES A. WITMER CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | TEL: 561-805-6715 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | CONSTRUCTION SERVICES HOME PAGE | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2012-02-06 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2012-02-06 |
Time |
12:32 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2012-02-03 |
Time |
16:03 |
Sent To |
|
|
Notes |
2012-02-03 16:03:53 | PROVISO: | | | | A SEPARATE PERMIT AND PLAN IS REQUIRED FOR THE PAINT | | SPRAY BOOTHS. | | | | | | ROBERT LECKY | | COMMERCIAL COMBINATION PLANS EXAMINER | | [email protected] | | ROBERT LECKY | | COMMERCIAL COMBINATION PLANS EXAMINER | | [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2011-09-27 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2011-09-27 |
Time |
15:43 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2011-09-27 |
Time |
15:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2011-08-17 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2011-08-17 |
Time |
11:31 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2011-08-10 |
Time |
11:38 |
Sent To |
|
|
Notes |
2011-08-17 11:32:40 | PROVISO: | | | | A SEPARATE PERMIT AND PLAN IS REQUIRED FOR THE PAINT | | SPRAY BOOTHS. | | | | | | ROBERT LECKY | | COMMERCIAL COMBINATION PLANS EXAMINER | | [email protected] | | ROBERT LECKY | | COMMERCIAL COMBINATION PLANS EXAMINER | | [email protected] | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
4 |
Status |
P |
Date |
2012-03-05 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2012-03-05 |
Time |
14:53 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2012-03-05 |
Time |
14:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
F |
Date |
2012-02-07 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2012-02-07 |
Time |
11:22 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2012-02-07 |
Time |
11:22 |
Sent To |
|
|
Notes |
2012-02-07 11:22:35 | 2301 OKEECHOBEE BOULEVARD - BUILDING 1, 2 & 3 | | PERMIT #11070617 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | SHEET 1-A1.0 | | PARTS #1128 - MEZZANINE STAIRS SHALL BE 36" WIDE | | MINIMUM. | | | | PROVIDE FIRE RATED SEPARATION BETWEEN PARTS (STORAGE) | | AND BUSINESS OCCUPANCY. PROTECT ALL OPENINGS AND | | PENETRATIONS. | | NOTE: THE RATED WALLS AND DOORS DO NOT AGREE BETWEEN | | PLAN SHEETS 1-A1.0 AND 1-A3.0. | | | | SHEET A1.1 | | PARTS #2109 - THE MEZZANINE MAY BE REQUIRED TO BE | | LIMITED TO 1/3 OR 1/2 THE AREA OF THE FLOOR BELOW. | | | | SHEET 1-A2.0 | | PROVIDE MINIMUM CEILING HEIGHT OF 7'-6". NEED VENDOR | | SHELVING LAYOUT TO COMPARE TO SURFACE MOUNTED CEILING | | LIGHT LOCATIONS. | | | | NEED AN ADDITIONAL EXIT SIGN TO LEAD TO SECONDARY EXIT | | IN PARTS #1128. | | | | CUSTOMER WAITING #1117 HAS EXIT SIGNS ROUTING OCCUPANTS | | TO A MORE HAZARDOUS OCCUPANCY. | | | | SHEET 1-A3.0 | | RELOCATE TABLES AND CHAIRS (NEAR TWO SOUTH DOUBLE EXIT | | DOORS) TO KEEP DIRECT UNOBSTRUCTED PATH TO EXITS. | | | | PROVIDE EXIT SIGN FOR PARTS STORAGE EAST EXIT AND MINOR | | REPAIRS AREA NORTH EXIT. | | NOTE: THE RCP EXIT SIGN LOCATIONS DO NOT MATCH ON | | SHEETS 1-A2.0 AND 1-A3.0. | | | | SHEET 1-A3.1 | | THE MAXIMUM OCCUPANT LOAD FOR THE BUSINESS MEZZANINE | | NEEDS TO BE SHOWN AS 10 PERSONS, OTHERWISE AN | | ADDITIONAL EXIT IS REQUIRED. | | | | SHEET 3-A5.0 | | INDICATE WHAT MATERIALS AND QUANTITIES OF MATERIALS | | WILL BE STORED IN DETAIL STORAGE #1311. | | | | GENERAL | | PROVIDE GUARD RAIL FOR PARTS MEZZANINE. | | | | STORAGE NEEDS TO BE MAINTAINED AT 24" BELOW THE CEILING | | OR STRUCTURE IN THE PARTS MEZZANINE. | | | | WESLEY JOLIN | | WEST PALM BEACH FIRE RESCUE | | FIRE & LIFE SAFETY PLAN REVIEW |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2011-10-13 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2011-10-13 |
Time |
14:59 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2011-10-13 |
Time |
14:59 |
Sent To |
|
|
Notes |
2011-10-13 14:59:19 | 2301 OKEECHOBEE BOULEVARD - BUILDING 1, 2 & 3 | | PERMIT #11070617 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | PROVIDE A DETAILED SITE PLAN INDICATING FIRE DEPARTMENT | | VEHICLE ACCESS WIDTHS, MARKED FIRE LANES, FIRE HYDRANT | | LOCATIONS, PERIMETER GATES/FENCES, CONSTRUCTION | | TRAILERS ETC. | | | | BUILDING #2: IF POSSIBLE, RELOCATE KNOXBOX AND FIRE | | ALARM ANUNCIATOR PANEL NEAR AN EAST ENTRY DOOR AS THIS | | WILL BE THE ACCESS SIDE FOR EMERGENCY RESPONDERS. THE | | WEST SIDE OF THE BUILDING ABUTTS THE FENCE AND PROPERTY | | LINE. | | | | PER LOCAL CODE AMENDMENTS, DUCT SMOKE DETECTORS SHALL | | INITIATE A GENERAL FIRE ALARM CONDITION. | | | | DRAWINGS WILL BE STAMPED, INITIALED, AND DATED BY THE | | FIRE DEPARTMENT AFTER ALL OTHER PLAN REVIEWER COMMENTS | | HAVE BEEN SATISFIED. | | | | WESLEY JOLIN | | WEST PALM BEACH FIRE RESCUE | | FIRE & LIFE SAFETY PLAN REVIEW |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2011-08-11 |
|
|
Cont ID |
|
Sent By |
wjolin |
Date |
2011-08-11 |
Time |
09:20 |
Rev Time |
0.00 |
Received By |
wjolin |
Date |
2011-08-11 |
Time |
09:20 |
Sent To |
|
|
Notes |
2011-08-11 09:20:21 | 2301 OKEECHOBEE BOULEVARD - BUILDING 1, 2 & 3 | | PERMIT #11070617 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | DESIGN SHALL CONFORM TO THE 2007 EDITION OF THE FLORIDA | | FIRE PREVENTION CODE WHICH CONTAINS THE FLORIDA EDITION | | OF NFPA 1 AND NFPA 101. | | | | PROVIDE A DETAILED SITE PLAN INDICATING FIRE DEPARTMENT | | VEHICLE ACCESS WIDTHS, MARKED FIRE LANES, FIRE HYDRANT | | LOCATIONS, PERIMETER GATES/FENCES, CONSTRUCTION | | TRAILERS ETC. | | | | ALL DEMOLITION WORK SHALL CONFORM TO THE REQUIREMENTS | | OF NFPA 241. TRASH AND DEBRIS TO BE REMOVED FROM THE | | SITE DAILY. | | | | FIRE PROTECTION SYSTEMS SHALL REMAIN ACTIVE DURING | | DEMOLITION AND RENOVATION ACTIVITIES. IN THE EVENT A | | FIRE PROTECTION SYSTEM IS OUT OF SERVICE FOR MORE THAN | | 4-HOURS IN A 24-HOUR PERIOD, THE BUILDING SHALL BE | | PLACED UNDER A FIRE WATCH. ALL FIRE WATCH REQUESTS MUST | | BE SUBMITTED IN WRITING AND APPROVED BY THE OFFICE OF | | THE FIRE MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY. | | | | PROVIDE AN EXTERIOR KEY SAFE TO ALLOW EMERGENCY | | RESPONDERS NON-FORCIBLE ENTRY INTO THE BUILDINGS DURING | | NON-BUSINESS HOURS. A KEY SAFE CAN BE ORDERED FROM | | WWW.KNOXBOX.COM. | | | | PROVIDE BUILDING NUMBER AND BUILDING ADDRESS VISIBLE | | FROM THE STREET. NUMBERS SHALL BE AT LEAST SIX-INCHES | | IN HEIGHT AND SHALL CONTRAST THE BACKGROUND (REFERENCE: | | SECTION 10.12.1.2 OF THE FLORIDA FIRE PREVENTION CODE - | | NFPA 1). | | | | PROVIDE A LIFE SAFETY PLAN CLEARLY INDICATING FIRE | | RATED WALLS, FIRE RATED DOORS, OCCUPANT LOADS, EXIT | | SIGNS, EMERGENCY LIGHTING, TRAVEL DISTANCES, COMMON | | PATH OF TRAVEL, FIRE EXTINGUISHERS ETC. | | | | THE BUILDING IS FUNCTIONING AS A MULTIUSE OCCUPANCY. | | INDICATE IF THE BUILDING IS DESIGNED FOR MIXED USE | | (NON-SEPARATED) OR SEPARATED USE PER SECTION 6.1.14.2.1 | | OF NFPA 101 FLORIDA EDITION 2006. THE ONLY FIRE RATED | | SEPARATION APPEARS TO BE THE 2-HOUR FIRE BARRIER | | SEPARATING THE INTERIOR SERVICE BAYS FROM THE ADJACENT | | INTERIOR SPACE. | | | | THE SERVICE AREAS APPEAR TO BE FUNCTIONING MORE LIKE AN | | INDUSTRIAL/FACTORY OCCUPANCY THAN A STORAGE OCCUPANCY. | | | | INDICATE IF THE SERVICE AREAS AND BODY SHOP AREAS WILL | | BE FUNCTIONING AS A MAJOR OR MINOR REPAIR GARAGE AS PER | | SECTION 3.3.165.21.1 OF NFPA 1. | | | | NO SMOKING OR OPEN FLAME SIGNS TO BE POSTED IN ALL | | SERVICE AREAS, BODY SHOPS AND PAINT BOOTH AREAS. | | | | PROVIDE PORTABLE FIRE EXTINGUISHERS. EXTINGUISHERS | | SHALL HAVE A MINIMUM RATING OF 2A:10BC AND SHALL BE | | TAGGED BY A LICENSED FIRE EXTINGUISHER COMPANY. TRAVEL | | DISTANCE TO EXTINGUISHERS SHALL NOT EXCEED 75 FEET. | | | | THE BUSINESS OFFICES (#2101, #2104 ETC.) ARE INDICATED | | AS BEING LOCATED ON THE MEZZANINE; HOWEVER, THIS SPACE | | DOES NOT MEET THE DEFINITION OF A MEZZANINE (SECTION | | 8.6.9 NFPA 101) WHEREBY THE MEZZANINE SPACE IS OPEN TO | | THE FLOOR BELOW UNLESS THE OCCUPANT LOAD OF THE | | AGGREGATE AREA OF THE ENCLOSED SPACE DOES NOT EXCEED | | 10. | | | | PROVIDE TACTILE SIGNAGE AT ALL REQUIRED EXIT DOORS WITH | | EXIT SIGNS. | | | | HANDRAILS ARE REQUIRED TO BE INSTALLED ON BOTH SIDES OF | | STAIRS. | | | | SPRAYING OF FLAMMABLE LIQUIDS (PAINT) SHALL CONFORM TO | | THE REQUIMENTS OF NFPA 33. | | | | STORAGE AND HANDLING OF FLAMMABLE LIQUIDS SHALL CONFORM | | TO THE REQUIREMENTS OF NFPA 30. | | | | INDICATE THE QUANTITIES OF FLAMMABLE LIQUIDS TO BE | | HOUSED IN THE PAINT SHOP AND MIXING ROOM. | | | | PAINT SHOP #1304 TO BE PROVIDED WITH TWO EXITS WHEREBY | | ONE FIRE EVENT WILL NOT RESTRICT ACCESS TO BOTH EXITS. | | | | INDICATE THE AREAS THAT WILL BE PROTECTED BY A FIRE | | SUPPRESSION SYSTEM(S). | | | | SEPARATE PLANS AND PERMITS ARE REQUIRED FOR | | INSTALLATION OF FIRE SPRINKLERS, FIRE ALARMS, PAINT | | SPRAY BOOTHS AND ANY OTHER SPECIALTY TRADE. | | | | SHEET FA0.1 BOTH FIRE ALARM RISER DIAGRAMS INDICATED AS | | BUILDING #1. | | | | SHEET 1FA2.2 NOT SEALED BY ENGINEER. | | | | WESLEY JOLIN | | WEST PALM BEACH FIRE RESCUE | | FIRE & LIFE SAFETY PLAN REVIEW |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
N |
Date |
2012-03-02 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2012-03-02 |
Time |
09:55 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2012-03-02 |
Time |
09:55 |
Sent To |
|
|
Notes |
2012-03-02 09:55:40 | GAS REMOVED | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
P |
Date |
2011-08-16 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2011-08-16 |
Time |
09:45 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2011-08-16 |
Time |
09:44 |
Sent To |
|
|
Notes |
2011-08-16 09:45:10 | FBC PLUMBING 2007 REVIEW #1 | | INFORMATION REQUEST: | | | | 1. SHEET 7.1 GAS MAIN FROM METER SHOULD BE LABELED 2 | | POUND NATURAL GAS OR WHATEVER THE SUPPLIED HIGHER | | PRESSURE IS. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2012-03-27 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-03-27 |
Time |
08:09 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-02-27 |
Time |
16:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2012-03-27 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2012-03-27 |
Time |
08:09 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2012-01-19 |
Time |
17:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2011-11-17 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2011-11-03 |
Time |
14:33 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2011-09-22 |
Time |
16:26 |
Sent To |
|
|
Notes |
2011-09-23 16:22:46 | C--27 & 28 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2011-09-23 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2011-09-07 |
Time |
16:21 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2011-07-27 |
Time |
08:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2012-03-05 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2012-03-05 |
Time |
14:52 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2012-03-05 |
Time |
14:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2011-11-03 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2011-11-03 |
Time |
15:01 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2011-11-03 |
Time |
15:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2011-09-07 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2011-09-07 |
Time |
09:09 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2011-09-07 |
Time |
09:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2012-03-02 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2012-03-02 |
Time |
10:20 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2012-03-02 |
Time |
09:56 |
Sent To |
|
|
Notes |
2012-03-02 10:19:37 | REVISION REQUIRED SECTION 403 | | MINIMUM PLUMBING FACILITIES | | DRINKING FOUNTAIN REQUIRED |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2012-02-03 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2012-02-03 |
Time |
11:12 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2012-01-30 |
Time |
09:14 |
Sent To |
|
|
Notes |
2012-01-30 12:59:30 | FBC PLUMBING 2007 REVIEW #2 | | DENIED: | | | | 1. A DRINKING FOUNTAIN IS REQUIRED PER 403.1 MINIMUM | | PLUMBING FIXTURES | | | | 2. SHEET 3A-5.0 (6) SHOWS CAR WASH EQUIPMENT INSTALLED | | BY VENDER. PLEASE INCLUDE WATER PIPE AND BACKFLOW | | PROTECTION ON SHEETS 3P-3.1 AND P6.1 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2011-08-16 |
|
|
Cont ID |
|
Sent By |
lwagner |
Date |
2011-08-16 |
Time |
09:45 |
Rev Time |
0.00 |
Received By |
lwagner |
Date |
2011-08-05 |
Time |
11:19 |
Sent To |
|
|
Notes |
2011-08-16 09:41:41 | FBC PLUMBING 2007 REVIEW #1 | | INFORMATION REQUEST: | | | | 1. SHEET 7.1 GAS MAIN FROM METER SHOULD BE LABELED 2 | | POUND NATURAL GAS OR WHATEVER THE SUPPLIED HIGHER | | PRESSURE IS. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
5 |
Status |
P |
Date |
2012-03-23 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2012-03-23 |
Time |
14:26 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2012-03-23 |
Time |
14:26 |
Sent To |
|
|
Notes |
2012-03-23 14:26:20 | ZONING PLAN REVIEW | | ___________________________________________ | | | | DATE OF REVIEW: 03.23.2012 | | PERMIT NO.: 11070617 AND 11070619 | | ADDRESS: 2301 AND 2321 OKEECHOBEE BOULEVARD | | CONTRACTOR/CONTACT: | | TELEPHONE NO.: | | SCOPE OF REVIEW: RENOVATION TO EXISTING STRUCTURES/SITE | | FOR REESTABLISHMENT OF A CAR DEALERSHIP. | | ___________________________________________ | | | | REVIEW STATUS: PASSED WITH PROVISOS | | ___________________________________________ | | | | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | PROVISOS: | | | | 1. PRIOR TO THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY: | | | | A. A REVISED TRAFFIC CONCURRENCY LETTER SHALL BE | | PROVIDED FROM THE PALM BEACH COUNTY DEPARTMENT OF | | ENGINEERING AND PUBLIC WORKS ? TRAFFIC ENGINEERING | | DIVISION INDICATING THEIR REVIEW AND APPROVAL OF THE | | REVISED BUILDING SQUARE FOOTAGE. | | | | B. THE ENTIRE SITE SHALL BE BROUGHT INTO COMPLIANCE | | WITH ARTICLE XIV (LANDSCAPING) OF THE CITY'S ZONING AND | | LAND DEVELOPMENT REGULATIONS (ZLDRS) AS THE VALUE OF | | THE WORK EXCEEDS 50 PERCENT OF THE VALUE OF THE | | STRUCTURE [THESE REQUIRED IMPROVEMENTS ARE REFLECTED IN | | THE CPD APPLICATION THAT IS IN PROCESS, AND REFERENCED | | ABOVE]. ALL APPLICABLE PLANS (I.E. SITE PLANS, | | LANDSCAPE PLANS, ETC) WILL NEED TO BE SUBMITTED UNDER | | SEPARATE PERMITS. PLEASE ENSURE THAT ALL PLANS MATCH | | THOSE THAT ARE A PART OF THE CPD. UPON SUBMITTAL OF | | PERMIT APPLICATIONS FOR THE SITE WORK, LANDSCAPING, | | ETC. PLEASE ENSURE THAT DETAILS ARE PROVIDED FOR ALL | | IMPROVEMENTS SUCH AS GATES, FENCES, DUMPSTER | | ENCLOSURES, PARKING STRIPING, ETC. | | | | C. BUILDING #3: - THE ROOF TOP MECHANICAL EQUIPMENT | | SHALL BE SCREENED FROM VIEW. UPON INSTALLATION OF THE | | EQUIPMENT, AND PRIOR TO FINAL INSPECTION, A SITE VISIT | | SHALL COORDINATE WITH THE PLANNING DIVISION. IF IT IS | | DETERMINED THAT THE MECHANICAL EQUIPMENT IS VISIBLE, | | APPROPRIATE SCREENING SHALL BE ADDED. | | | | 2. ALL SITE LIGHTING SHALL BE SUBMITTED UNDER A | | SEPARATE PERMIT. | | | | A. A PHOTOMETRIC PLAN SHALL BE SUBMITTED TO THE CITY?S | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | INDICATING THAT ANY NEW SITE LIGHTING, OR UPGRADES TO | | EXISTING SITE LIGHTING, DO NOT EXCEED 1.0 FOOTCANDLES | | WHEN MEASURED AT THE BOUNDARY OF THE DEVELOPMENT. | | | | B. THE ELECTRICAL SITE PLAN DOES NOT MATCH THE SITE | | PLAN THAT IS PROPOSED AND RESULTS IN SEVERAL CONFLICTS | | BETWEEN LIGHTING LOCATION, PARKING, TREE INSTALLATION, | | ETC. PLEASE ENSURE THAT ALL PLANS ARE CONSISTENT. | | | | C. DETAILS NEED TO BE PROVIDED REGARDING PROPOSED LIGHT | | POLES, INCLUDING OVERALL HEIGHT. | | | | 3. PLEASE NOTE THAT ALL SIGNAGE WILL NEED TO CONFORM TO | | THE REQUIREMENTS OF THE GENERAL COMMERCIAL (GC) ZONING | | DISTRICT AND WILL BE REVIEWED UPON SUBMITTAL....THIS | | WILL NOT HOLD UP ISSUANCE OF A PERMIT, BUT IS JUST A | | REMINDER WHEN CONSIDERING SIGNAGE FOR THE DEVELOPMENT | | AND SUBMITTAL OF SIGN PERMITS. PLEASE NOTE THAT WALL | | SIGNS ARE LIMITED TO ONE (1) SIGN PER BUSINESS, PLUS | | TWO (2) ADDITIONAL SIGNS, RESULTING IN ONLY THREE (3) | | TOTAL SIGNS PERMITTED FOR THE PROJECT. | | | | 4. THE FENCING SURROUNDING THE OIL STORAGE PEN SHALL BE | | SOLID/OPAQUE, NOT CHAIN LINK. | | ___________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | ___________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN ROACH, SENIOR PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3366 | | WEST PALM BEACH, FLORIDA 33402 | | | | PHONE: 561.822.1435 | | FAX: 561.822.1460 | | | | EMAIL: [email protected] | | | | WWW.CITYOFWPB.COM | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
F |
Date |
2012-03-12 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2012-03-12 |
Time |
10:52 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2012-03-12 |
Time |
10:52 |
Sent To |
|
|
Notes |
2012-03-12 10:52:28 | ZONING PLAN REVIEW | | ___________________________________________ | | | | DATE OF REVIEW: 03.12.2012 | | PERMIT NO.: 11070617 AND 11070619 | | ADDRESS: 2301 OKEECHOBEE BOULEVARD | | CONTRACTOR/CONTACT: | | TELEPHONE NO.: | | SCOPE OF REVIEW: | | ___________________________________________ | | | | REVIEW STATUS: FAILED | | ___________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1. AN APPLICATION FOR A UNITY OF TITLE SHALL BE | | SUBMITTED TO THE CITY?S ENGINEERING SERVICES | | DEPARTMENT. UPON APPROVAL OF THE APPLICATION, THE UNITY | | OF TITLE SHALL BE RECORDED IN THE PUBLIC RECORDS OF | | PALM BEACH COUNTY, AND A CERTIFIED COPY SHALL BE | | SUBMITTED TO THE CITY?S DEVELOPMENT SERVICES DEPARTMENT | | ? PLANNING DIVISION. | | | | 2. A REVISED TRAFFIC CONCURRENCY LETTER SHALL BE | | PROVIDED FROM THE PALM BEACH COUNTY DEPARTMENT OF | | ENGINEERING AND PUBLIC WORKS ? TRAFFIC ENGINEERING | | DIVISION INDICATING THEIR REVIEW AND APPROVAL OF THE | | REVISED BUILDING SQUARE FOOTAGE. | | | | 3. A PHOTOMETRIC PLAN SHALL BE SUBMITTED TO THE CITY?S | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | INDICATING THAT ANY NEW SITE LIGHTING, OR UPGRADES TO | | EXISTING SITE LIGHTING, DO NOT EXCEED 1.0 FOOTCANDLES | | WHEN MEASURED AT THE BOUNDARY OF THE DEVELOPMENT. | | | | 4. A CONSTRUCTION SITE SECURITY AND MANAGEMENT PLAN | | SHALL BE SUBMITTED TO, AND APPROVED BY, THE CITY OF | | WEST PALM BEACH POLICE DEPARTMENT ? CRIME PREVENTION | | UNIT. | | | | 5. THE ENTIRE SITE SHALL BE BROUGHT INTO COMPLIANCE | | WITH ARTICLE XIV (LANDSCAPING) OF THE CITY'S ZONING AND | | LAND DEVELOPMENT REGULATIONS (ZLDRS) AS THE VALUE OF | | THE WORK EXCEEDS 50 PERCENT OF THE VALUE OF THE | | STRUCTURE [THESE REQUIRED IMPROVEMENTS ARE REFLECTED IN | | THE CPD APPLICATION THAT IS IN PROCESS, AND REFERENCED | | ABOVE]. ALL APPLICABLE PLANS (I.E. SITE PLANS, | | LANDSCAPE PLANS, ETC) WILL NEED TO BE SUBMITTED UNDER | | SEPARATE PERMITS. PLEASE ENSURE THAT ALL PLANS MATCH | | THOSE THAT ARE A PART OF THE CPD. UPON SUBMITTAL OF | | PERMIT APPLICATIONS FOR THE SITE WORK, LANDSCAPING, | | ETC. PLEASE ENSURE THAT DETAILS ARE PROVIDED FOR ALL | | IMPROVEMENTS SUCH AS GATES, FENCES, DUMPSTER | | ENCLOSURES, PARKING STRIPING, ETC. | | | | 6. PLEASE ENSURE THAT ALL FLOOR PLANS, ELEVATIONS, ETC. | | ARE CONSISTENT WITH THE PROPOSED SITE PLAN | | MODIFICATIONS. | | | | 7. PLEASE NOTE THAT ALL SIGNAGE WILL NEED TO CONFORM TO | | THE REQUIREMENTS OF THE GENERAL COMMERCIAL (GC) ZONING | | DISTRICT AND WILL BE REVIEWED UPON SUBMITTAL....THIS | | WILL NOT HOLD UP ISSUANCE OF A PERMIT, BUT IS JUST A | | REMINDER WHEN CONSIDERING SIGNAGE FOR THE DEVELOPMENT | | AND SUBMITTAL OF SIGN PERMITS. PLEASE NOTE THAT WALL | | SIGNS ARE LIMITED TO ONE (1) SIGN PER BUSINESS, PLUS | | TWO (2) ADDITIONAL SIGNS, RESULTING IN ONLY THREE (3) | | TOTAL SIGNS PERMITTED FOR THE PROJECT. | | | | 8. THE ELECTRICAL SITE PLAN DOES NOT MATCH THE SITE | | PLAN THAT IS PROPOSED AND RESULTS IN SEVERAL CONFLICTS | | BETWEEN LIGHTING LOCATION, PARKING, TREE INSTALLATION, | | ETC. PLEASE ENSURE THAT ALL PLANS ARE CONSISTENT. | | | | 9. DETAILS NEED TO BE PROVIDED REGARDING PROPOSED LIGHT | | POLES, INCLUDING OVERALL HEIGHT. | | | | 10. PLEASE NOTE THAT PARKING SPACES ADJACENT TO | | REQUIRED LANDSCAPE BUFFERS WILL NEED TO HAVE WHEEL | | STOPS (OR THE CURB LINE MOVED IN) TO KEEP VEHICLES FROM | | OVERHANGING INTO THE REQUIRED LANDSCAPE AREA. THE SITE | | PLAN PROPOSED AS PART OF THE CPD APPLICATION ADDRESSES | | THIS COMMENT. | | | | 11. THE FENCING SURROUNDING THE OIL STORAGE PEN SHALL | | BE SOLID/OPAQUE, NOT CHAIN LINK. | | | | 12. BUILDING #1: | | | | A. THE STAIRS ON THE SOUTH SIDE OF BUILDING #1 ARE | | INCONSISTENT WITH THE PROPOSED SITE PLAN AND ENCROACH | | INTO THE PROPOSED PARKING SPACES. | | | | 13. BUILDING #3: | | | | A. PLEASE PROVIDE INFORMATION REGARDING THE ROOF-TOP | | MECHANICAL EQUIPMENT ON TOP OF BUILDING #3. IT APPEARS | | THAT THERE IS NO PARAPET, AND THE MECHANICAL EQUIPMENT | | SHALL BE SCREENED FROM VIEW. | | ___________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | ___________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN ROACH, SENIOR PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3366 | | WEST PALM BEACH, FLORIDA 33402 | | | | PHONE: 561.822.1435 | | FAX: 561.822.1460 | | | | EMAIL: [email protected] | | | | WWW.CITYOFWPB.COM | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2012-02-10 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2012-02-10 |
Time |
10:24 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2012-02-07 |
Time |
16:20 |
Sent To |
|
|
Notes |
2012-02-10 10:24:52 | ZONING PLAN REVIEW | | ___________________________________________ | | | | DATE OF REVIEW: 02.10.2012 | | PERMIT NO.: 11070617 AND 11070619 | | ADDRESS: 2301 OKEECHOBEE BOULEVARD, #1 & #3 | | CONTRACTOR/CONTACT: | | TELEPHONE NO.: | | SCOPE OF REVIEW: RENOVATIONS TO EXISTING CAR SALES | | FACILITY. | | ___________________________________________ | | | | REVIEW STATUS: FAILED | | ___________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | GENERAL COMMENTS: | | | | 1. PRIOR TO THE ISSUANCE OF A BUILDING PERMIT, THE | | COMMERCIAL PLANNED DEVELOPMENT (CPD) APPLICATION | | SUBMITTED TO THE CITY'S PLANNING AND ZONING DEPARTMENT | | SHALL BE APPROVED BY THE CITY COMMISSION. | | | | 2. THE ENTIRE SITE SHALL BE BROUGHT INTO COMPLIANCE | | WITH ARTICLE XIV (LANDSCAPING) OF THE CITY'S ZONING AND | | LAND DEVELOPMENT REGULATIONS (ZLDRS) AS THE VALUE OF | | THE WORK EXCEEDS 50 PERCENT OF THE VALUE OF THE | | STRUCTURE [THESE REQUIRED IMPROVEMENTS ARE REFLECTED IN | | THE CPD APPLICATION THAT IS IN PROCESS, AND REFERENCED | | ABOVE]. ALL APPLICABLE PLANS (I.E. SITE PLANS, | | LANDSCAPE PLANS, ETC) WILL NEED TO BE SUBMITTED UNDER | | SEPARATE PERMITS. PLEASE NOTE THAT THE SITE PLAN | | SUBMITTED AS PART OF THIS PERMIT APPLICATION DOES NOT | | CORRESPOND WITH THE SITE PLAN THAT IS PROPOSED AS PART | | OF THE CPD APPLICATION. PLEASE ENSURE THAT ALL PLANS | | MATCH THOSE THAT ARE A PART OF THE CPD. UPON SUBMITTAL | | OF PERMIT APPLICATIONS FOR THE SITE WORK, LANDSCAPING, | | ETC. PLEASE ENSURE THAT DETAILS ARE PROVIDED FOR ALL | | IMPROVEMENTS SUCH AS GATES, FENCES, DUMPSTER | | ENCLOSURES, PARKING STRIPING, ETC. | | | | 3. PLEASE ENSURE THAT ALL FLOOR PLANS, ELEVATIONS, ETC. | | ARE CONSISTENT WITH THE PROPOSED SITE PLAN | | MODIFICATIONS. | | | | 4. PLEASE NOTE THAT ALL SIGNAGE WILL NEED TO CONFORM TO | | THE REQUIREMENTS OF THE GENERAL COMMERCIAL (GC) ZONING | | DISTRICT AND WILL BE REVIEWED UPON SUBMITTAL....THIS | | WILL NOT HOLD UP ISSUANCE OF A PERMIT, BUT IS JUST A | | REMINDER WHEN CONSIDERING SIGNAGE FOR THE DEVELOPMENT | | AND SUBMITTAL OF SIGN PERMITS. PLEASE NOTE THAT WALL | | SIGNS ARE LIMITED TO ONE (1) SIGN PER BUSINESS, PLUS | | TWO (2) ADDITIONAL SIGNS?RESULTING IN ONLY THREE (3) | | TOTAL SIGNS PERMITTED FOR THE PROJECT. | | | | 5. THE ELECTRICAL SITE PLAN DOES NOT MATCH THE SITE | | PLAN THAT IS PROPOSED AND RESULTS IN SEVERAL CONFLICTS | | BETWEEN LIGHTING LOCATION, PARKING, TREE INSTALLATION, | | ETC. PLEASE ENSURE THAT ALL PLANS ARE CONSISTENT. | | | | 6. A PHOTOMETRIC PLAN SHALL BE PROVIDED INDICATING | | NUMBER OF FOOTCANDLES AS MEASURED AT THE PROPERTY | | LINES. LIGHTING SHALL NOT EXCEED 1.0 FOOTCANDLES AT THE | | PROPERTY LINE. | | | | 7. DETAILS NEED TO BE PROVIDED REGARDING PROPOSED LIGHT | | POLES, INCLUDING OVERALL HEIGHT. | | | | 8. PLEASE NOTE THAT PARKING SPACES ADJACENT TO REQUIRED | | LANDSCAPE BUFFERS WILL NEED TO HAVE WHEEL STOPS (OR THE | | CURB LINE MOVED IN) TO KEEP VEHICLES FROM OVERHANGING | | INTO THE REQUIRED LANDSCAPE AREA. THE SITE PLAN | | PROPOSED AS PART OF THE CPD APPLICATION ADDRESSES THIS | | COMMENT. | | | | 9. THE FENCING SURROUNDING THE OIL STORAGE PEN SHALL BE | | SOLID/OPAQUE, NOT CHAIN LINK. | | | | BUILDING #1: | | | | 1. THE STAIRS ON THE SOUTH SIDE OF BUILDING #1 ARE | | INCONSISTENT WITH THE PROPOSED SITE PLAN AND ENCROACH | | INTO THE PROPOSED PARKING SPACES. | | | | BUILDING #3: | | | | 1. PLEASE PROVIDE INFORMATION REGARDING THE ROOF-TOP | | MECHANICAL EQUIPMENT ON TOP OF BUILDING #3. IT APPEARS | | THAT THERE IS NO PARAPET?AND THE MECHANICAL EQUIPMENT | | SHALL BE SCREENED FROM VIEW. | | ___________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | ___________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN ROACH, SENIOR PLANNER | | CITY OF WEST PALM BEACH | | PLANNING AND ZONING DEPARTMENT | | 401 CLEMATIS STREET - P.O. BOX 3366 | | WEST PALM BEACH, FLORIDA 33402 | | | | PHONE: 561.822.1435 | | FAX: 561.822.1460 | | | | EMAIL: [email protected] | | | | WWW.CITYOFWPB.COM | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2011-10-06 |
|
|
Cont ID |
|
Sent By |
|
Date |
2011-10-06 |
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
2011-10-06 |
Time |
|
Sent To |
|
|
Notes |
2011-11-17 09:29:40 | ZONING PLAN REVIEW | | ___________________________________________ | | | | DATE OF REVIEW: 10.06.2011 | | PERMIT NO.: 11070617, 11070618, AND 11070619 | | ADDRESS: 2301 OKEECHOBEE BOULEVARD, #1-3 | | CONTRACTOR/CONTACT: | | TELEPHONE NO.: | | SCOPE OF REVIEW: RENOVATIONS TO EXISTING CAR SALES | | FACILITY. | | ___________________________________________ | | | | REVIEW STATUS: FAILED | | ___________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | GENERAL COMMENTS: | | | | 1. PRIOR TO THE ISSUANCE OF A BUILDING PERMIT, THE | | COMMERCIAL PLANNED DEVELOPMENT (CPD) APPLICATION | | SUBMITTED TO THE CITY'S PLANNING AND ZONING DEPARTMENT | | SHALL BE APPROVED BY THE CITY COMMISSION. | | | | 2. THE ENTIRE SITE SHALL BE BROUGHT INTO COMPLIANCE | | WITH ARTICLE XIV (LANDSCAPING) OF THE CITY'S ZONING AND | | LAND DEVELOPMENT REGULATIONS (ZLDRS) AS THE VALUE OF | | THE WORK EXCEEDS 50 PERCENT OF THE VALUE OF THE | | STRUCTURE [THESE REQUIRED IMPROVEMENTS ARE REFLECTED IN | | THE CPD APPLICATION THAT IS IN PROCESS, AND REFERENCED | | ABOVE]. ALL APPLICABLE PLANS (I.E. SITE PLANS, | | LANDSCAPE PLANS, ETC) WILL NEED TO BE SUBMITTED UNDER | | SEPARATE PERMITS. | | | | 3. PLEASE ENSURE THAT ALL FLOOR PLANS, ELEVATIONS, ETC. | | ARE CONSISTENT WITH THE PROPOSED SITE PLAN | | MODIFICATIONS. SEE MORE SPECIFIC COMMENTS BELOW. | | | | 4. PLEASE NOTE THAT ALL SIGNAGE WILL NEED TO CONFORM TO | | THE REQUIREMENTS OF THE GENERAL COMMERCIAL (GC) ZONING | | DISTRICT AND WILL BE REVIEWED UPON SUBMITTAL....THIS | | WILL NOT HOLD UP ISSUANCE OF A PERMIT, BUT IS JUST A | | REMINDER WHEN CONSIDERING SIGNAGE FOR THE DEVELOPMENT | | AND SUBMITTAL OF SIGN PERMITS. | | | | 5. THE ELECTRICAL SITE PLAN DOES NOT MATCH THE SITE | | PLAN THAT IS PROPOSED. | | | | 6. THERE ARE SEVERAL LOCATIONS WHERE EXISTING LIGHT | | POLES CONFLICT WITH THE PROPOSED SITE PLAN. A) THERE IS | | A POLE TO THE NORTH OF BUILDING #3 THAT APPEARS THAT IT | | MAY BE LOCATED IN THE PARKING LOT DRIVE AISLE. PLEASE | | CONFIRM THAT IT WILL BE OUTSIDE OF THE MINIMUM 24 CLEAR | | WIDTH REQUIREMENT. B) THERE IS A POLE BETWEEN BUILDINGS | | #2 AND #3...THIS SPACE WILL NEED TO BE STRIPED AS "NO | | PARKING" OR THE POLE WILL NEED TO BE RELOCATED. C) | | THERE IS A POLE TO THE NORTH OF BUILDING #1...IT IS | | PREFERRED THAT THIS POLE BE RELOCATED, BUT AS LONG AS | | THIS IS MAINTAINED AS INVENTORY PARKING ONLY, IT MAY BE | | ABLE TO REMAIN. D) THERE IS ONE POLE SOUTH OF BUILDING | | #2 THAT IS LOCATED IN THE DRIVE AISLE.....THE CURB FOR | | THE LANDSCAPE ISLAND COULD BE EXTENDED OUT TO ENCOMPASS | | THIS POLE, SO LONG AS 20 MINIMUM WIDTH IS MAINTAINED | | BETWEEN THE ISLAND AND THE CURB TO THE WEST. E) THERE | | ARE 3 POLES AT THE HEAD OF PARKING SPACES SOUTH OF | | BUILDING #2...THESE WILL NEED TO BE STRIPED AS | | "COMPACT" SPACES AND THE WHEEL STOPS ADJUSTED TO | | PROVIDE THE 2-FOOT CLEAR OVERHANG. | | | | 7. PLEASE NOTE THAT PARKING SPACES ADJACENT TO REQUIRED | | LANDSCAPE BUFFERS WILL NEED TO HAVE WHEEL STOPS (OR THE | | CURB LINE MOVED IN) TO KEEP VEHICLES FROM OVERHANGING | | INTO THE REQUIRED LANDSCAPE AREA. | | | | BUILDING #1: | | | | 1. THE WESTERN-MOST STAIR ON THE SOUTH SIDE OF BUILDING | | #1 IS INCONSISTENT WITH THE PROPOSED SITE PLAN AND | | ENCROACHES INTO THE PROPOSED PARKING SPACES. | | | | BUILDING #2: | | | | 1. THE STAIRWAYS AND HANDICAP RAMP ON THE SOUTH SIDE OF | | THE BUILDING APPEAR TO CONFLICT WITH THE PROPOSED | | PARKING LAYOUT....THE HC RAMP AND STAIRS WOULD ENCROACH | | INTO THE PROPOSED PARKING. | | | | ___________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | ___________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN ROACH, SENIOR PLANNER | | CITY OF WEST PALM BEACH | | PLANNING AND ZONING DEPARTMENT | | 401 CLEMATIS STREET - P.O. BOX 3366 | | WEST PALM BEACH, FLORIDA 33402 | | | | PHONE: 561.822.1435 | | FAX: 561.822.1460 | | | | EMAIL: [email protected] | | | | WWW.CITYOFWPB.COM | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2011-08-14 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2011-08-14 |
Time |
14:12 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2011-08-14 |
Time |
14:12 |
Sent To |
|
|
Notes |
2011-08-14 14:12:14 | ZONING PLAN REVIEW | | ___________________________________________ | | | | DATE OF REVIEW: 08.14.2011 | | PERMIT NO.: 11070617, 11070618, AND 11070619 | | ADDRESS: 2301 OKEECHOBEE BOULEVARD, #1-3 | | CONTRACTOR/CONTACT: | | TELEPHONE NO.: | | SCOPE OF REVIEW: RENOVATIONS TO EXISTING CAR SALES | | FACILITY. | | ___________________________________________ | | | | REVIEW STATUS: FAILED | | ___________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | GENERAL COMMENTS: | | | | 1. PRIOR TO THE ISSUANCE OF A BUILDING PERMIT, THE | | COMMERCIAL PLANNED DEVELOPMENT (CPD) APPLICATION | | SUBMITTED TO THE CITY?S PLANNING AND ZONING DEPARTMENT | | SHALL BE APPROVED BY THE CITY COMMISSION. | | | | 2. THE ENTIRE SITE SHALL BE BROUGHT INTO COMPLIANCE | | WITH ARTICLE XIV (LANDSCAPING) OF THE CITY?S ZONING AND | | LAND DEVELOPMENT REGULATIONS (ZLDRS) AS THE VALUE OF | | THE WORK EXCEEDS 50 PERCENT OF THE VALUE OF THE | | STRUCTURE [THESE REQUIRED IMPROVEMENTS ARE REFLECTED IN | | THE CPD APPLICATION THAT IS IN PROCESS, AND REFERENCED | | ABOVE]. ALL APPLICABLE PLANS (I.E. SITE PLANS, | | LANDSCAPE PLANS, ETC) WILL NEED TO BE SUBMITTED. | | | | 3. PLEASE ENSURE THAT ALL FLOOR PLANS, ELEVATIONS, ETC. | | ARE CONSISTENT WITH THE PROPOSED SITE PLAN | | MODIFICATIONS. | | | | 4. THE TOTAL SQUARE FOOTAGES SHOWN ON THE COVER SHEET | | DO NOT MATCH THOSE THAT WERE SUBMITTED AS PART OF THE | | CPD APPLICATION REFERENCED ABOVE. PLEASE ENSURE THAT | | ALL PLANS ARE CONSISTENT. | | | | 5. PLEASE NOTE THAT ALL SIGNAGE WILL NEED TO CONFORM TO | | THE REQUIREMENTS OF THE GENERAL COMMERCIAL (GC) ZONING | | DISTRICT AND WILL BE REVIEWED UPON SUBMITTAL. | | | | 6. ALL MECHANICAL AND ELECTRICAL EQUIPMENT (I.E. | | TRANSFORMERS ON THE WEST SIDES OF BUILDINGS #1 AND #2), | | WILL NEED TO BE SCREENED. | | | | 7. THE EXISTING LIGHT POLE SHOWN IN THE INVENTORY | | PARKING AREA CONFLICTS WITH THE DRIVE AISLE AND WILL | | NEED TO BE REMOVED OR RELOCATED. | | | | 8. THE EXISTING LIGHT POLE SOUTH OF THE BODY SHOP | | CONFLICTS WITH A PARKING SPACE. THIS SPACE WILL NEED TO | | BE STRIPED AS ?NO PARKING? OR THE POLE WILL NEED TO BE | | REMOVED OR RELOCATED. | | | | BUILDING #1: | | | | 1. THE TWO (2) STAIRWAYS ON THE SOUTH SIDE OF BUILDING | | 1, FROM THE ELEVATED DISPLAY AREA, ENCROACH IN THE | | PARKING SPACES PROPOSED. | | | | 2. THE FLOOR PLANS DO NOT MATCH THE ELEVATIONS. THE | | HANDICAP RAMP IS SHOWN GOING IN DIFFERENT DIRECTIONS. | | | | 3. THE FLOOR PLAN SHOWS DOORWAYS EXISTING THE EAST | | FACADE OF THE BUILDING FROM THE DETAIL AND EXPRESS OIL | | OFFICES. A LANDSCAPE ISLAND IS BEING PROPOSED JUST EAST | | OF THESE DOORWAYS. THEREFORE, IT APPEARS THAT THE | | EXITING OF THESE OFFICES WILL CONFLICT WITH THE | | PROPOSED LANDSCAPING. | | | | BUILDING #2: | | | | 1. THE STAIRWAYS AND HANDICAP RAMP ON THE SOUTH SIDE OF | | THE BUILDING APPEAR TO CONFLICT WITH THE PROPOSED | | PARKING LAYOUT. | | | | 2. THE VEHICLE RAMP PROPOSED ON THE EAST SIDE OF THE | | BUILDING APPEARS TO ENCROACH INTO THE DRIVEWAY BETWEEN | | BUILDINGS #1 AND #2. THIS DRIVEWAY SHALL REMAIN 24 FEET | | IN CLEAR WIDTH. THIS WILL NEED TO BE VERIFIED ON THE | | SITE PLAN. | | | | BUILDING #3 | | | | 1. PLEASE NOTE THAT THE TITLE BLOCK ON SHEET 3-A4.0 AND | | SHEET 3-A5.0 INDICATE BUILDING #1, WHEN THEY SHOULD | | INDICATE BUILDING #3. | | ___________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | ___________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN ROACH, SENIOR PLANNER | | CITY OF WEST PALM BEACH | | PLANNING AND ZONING DEPARTMENT | | 401 CLEMATIS STREET - P.O. BOX 3366 | | WEST PALM BEACH, FLORIDA 33402 | | | | PHONE: 561.822.1435 | | FAX: 561.822.1460 | | | | EMAIL: [email protected] | | | | WWW.CITYOFWPB.COM | | |
|
|
|