Plan Review Details - Permit 11070054
Plan Review Stops For Permit 11070054
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2011-07-27 Cont ID  
Sent By jwitmer Date 2011-07-27 Time 14:10 Rev Time 1.00
Received By jwitmer Date 2011-07-27 Time 14:10 Sent To  
Notes
2011-07-27 14:12:05BUILDING PLAN REVIEW
 PERMIT: 11070054
 ADD: 771 VILLAGE BLVD SUITE 212-213
 CONT: TO BE DETERMINED
 TEL: (954)583-9990
  
 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 2007 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
 BUILDING PROVISO:
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO
 INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE
 ASSESSMENT OF RE-INSPECTION FEE(S). REVISIONS REQUIRE
 ADDITIONAL REVIEWS WITH ASSOCIATED FEES.
  
 FL BLD CODE 1609.6.2.2 COMPONENTS & CLADDING, PROVIDE 2
 COPIES OF PRODUCT TESTING REPORTS, MISSING REPORTS ARE
 AS FOLLOWS:
 1) STOREFRONT DOOR
  
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-07-11 Cont ID  
Sent By jwitmer Date 2011-07-11 Time 08:30 Rev Time 0.50
Received By jwitmer Date 2011-07-11 Time 08:00 Sent To  
Notes
2011-07-11 08:31:37BUILDING PLAN REVIEW
 PERMIT: 11070054
 ADD: 771 VILLAGE BLVD SUITE 212-213
 CONT: TO BE DETERMINED
 TEL: (954)583-9990
  
 2007 FLORIDA BUILDING CODE W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 2007 EXISTING BUILDING CODE LEVEL II 701.3
 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 ACTION: DENIED
  
 1) CONTRACTOR TO SIGN ONTO PERMIT APPLICATION BEFORE
 ISSANCE, VERIFY LICENSURE AND INSURANCE.
  
 2) SHEET A1 NOTE #8 INDICATES THE WATER HEATER TO BE
 INSTALLED OVER THE RESTROOM CEILING, PLEASE SEE SHEET
 A2.1 DETAIL # 7 INDICATES TTHE WATER HEATER LOCATION TO
 BE OVER THE JANITORS CLOSET, EVEN THE PLUMBING SHEET
 P-3 THE TWO ISOMETRICS INDICATE THE WATER HEATER IN TWO
 LOCATIONS.
  
 3) PLEASE ALSO PROVIDE ADDITIONAL DETAILS FOR POINT
 LOADING OF THE BAR JOIST:
 3A) IF THE LOCATION OF TTHE WATER HEATER IS OVER THE
 JANITORS CLOSET THE BAR JOIST BOTTOM CHORD USALLY DOES
 NOT CONTINUE TO THE BEARING WALL AND BRIDGING IS USALLY
 WELDED ONTO THE BOTTOM CHORD, IF THIS CONDITION EXIST
 HOW WILL THE HEATER BE HUNG FROM BAR JOIST.
  
 3B) IF THE LOCATION OF THE WATER HEATER IS LOCATED OVER
 THE RESTROOM PLEASE LOCATE ON PLANS?
  
 4) SHEET A2.1 NOTE #1 INDICATES THE STOREFRONT TO BE
 REMOVED AND NEW SYSTEM TO INSTALLED:
  
 4A) MISSING WIND DESIGN, 1609.6.2 WIND DESIGN
 PROCEDURES
 4A)1) THE BASIC WIND SPEED, V, SHALL BE DETERMINED IN
 ACCORDANCE WITH SECTION 1609.3. THE WIND SHALL BE
 ASSUMED TO COME FROM ANY HORIZONTAL DIRECTION.
  
 4A) 2) AN IMPORTANCE FACTOR, IW, SHALL BE DETERMINED IN
 ACCORDANCE WITH SECTION1609.5.
  
 4A) 3) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN
 ACCORDANCE WITH 1609.4.
  
 4A) 4) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, *
 SHALL BE DETERMINED FROM TABLE 1609.6.2.1(4)
  
 4A) 5) PRESSURES +/-.
  
 5) FL BLD CODE 1609.6.2.2 COMPONENTS & CLADDING,
 PROVIDE 2 COPIES OF PRODUCT TESTING REPORTS, MISSING
 REPORTS ARE AS FOLLOWS:
 1) STOREFRONT DOOR
  
 2) STOREFRONT GLAZING
  
 3) STORM SHUTTERS IF LARGE MISSILE IMPACT RESISTANT
 TESTED GLAZING SYSTEMS IS NOT INSTALLED.
  
 6) 106.3.3 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE
 REGULATED BY THE DCA RULE 9B-72 SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO
 SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 7) SHEET A2.1 NOTE NOTE # 2 INDICATEES PEIR TO BE
 REPLACED, PLEASE PROVIDE DETAILS TO WHAT IS THE
 STRUCTURAL BASE OF THIS PIER AND WHAT WILL BE ADDED TO
 THIS PIER FOR THE WINDOW FRAME TO ATTACH TO FOR
 ANCHORING. 2007/ 09 FBC-B 1609 WIND LOADING AND PART OF
 THE MWFRS.
  
 JAMES A. WITMER C.B.O.
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: (561)805-6715
 FAX:(561)805-6731
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2011-07-14 Cont ID  
Sent By rlecky Date 2011-07-14 Time 08:59 Rev Time 0.00
Received By rlecky Date 2011-07-14 Time 07:46 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2011-07-12 Cont ID  
Sent By wjolin Date 2011-07-12 Time 13:23 Rev Time 0.00
Received By wjolin Date 2011-07-12 Time 11:48 Sent To  
Notes
2011-07-12 13:23:34701 VILLAGE BOULEVARD, SUITE #212-213
 PERMIT #11070054
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 PROVIDE PROJECT ADDRESS ON PLANS.
  
 WESLEY JOLIN
 WEST PALM BEACH FIRE RESCUE
 FIRE & LIFE SAFETY PLAN REVIEW
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-07-27 Cont ID  
Sent By jwitmer Date 2011-07-27 Time 14:10 Rev Time 0.00
Received By jwitmer Date 2011-07-26 Time 13:35 Sent To  
Notes
2011-07-27 12:45:27***** EXPEDITED ****
  
 7/27 TO JW DESK
  
2011-07-26 13:35:32*******************EXPEDITED********************
 GAVE TO HAROLD

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-07-14 Cont ID  
Sent By rlecky Date 2011-07-14 Time 09:05 Rev Time 0.00
Received By rlecky Date 2011-07-07 Time 10:35 Sent To  
Notes
2011-07-08 16:27:03********************EXPEDITED*************************
 7/8/11
2011-07-07 10:35:44B--14

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2011-07-27 Cont ID  
Sent By hmoser Date 2011-07-27 Time 12:57 Rev Time 0.00
Received By hmoser Date 2011-07-27 Time 09:50 Sent To  
Notes
2011-07-27 12:47:19PROVISO
  
 DAMPER REQUIRED AT OUTSIDE AIR DUCT, FBC 13-409.AB
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2011-07-13 Cont ID  
Sent By shill Date 2011-07-13 Time 13:00 Rev Time 0.00
Received By hmoser Date 2011-07-13 Time 13:00 Sent To  
Notes
2011-07-13 13:01:02****CORRECTIONS****
 11070054
  
 1. DETAIL 5 SHEET M2 NOT COMPLETE; ATTACHMENT TO
 STRUCTURE NOT SPECIFIED (STATES EXTEND TO STRUCTURE.
 REFER TO DETAIL). PLEASE PROVIDE NEW DETAIL OR REVISE
 EXISTING DETAIL, FBC MECHANICAL 302.
  
 2. M1, PLAN NOTE 1 STATES THAT CONDENSATE WILL BE
 DIRECTED TO MOP SINK. SEE WPB MUNICIPAL CODE 90 25, FBC
 MECHANICAL 307.2.1, THIS IS PROHIBITED. PLEASE REVISE.
  
 3. SHOW COMPLIANCE WITH FBC MECHANICAL 606.2.2 DUCT
 SMOKE DETECTORS.
  
 4. PLEASE REVISE PLAN TO SHOW COMPLIANCE WITH FBC
 MECHANICAL 606.4, FAN SHUTDOWN.
  
 5. PLEASE REVISE PLAN TO SHOW COMPLIANCE WITH FBC
 MECHANICAL 606.4.1 AND CLARIFY JOB CONDITIONS.
 MECHANICAL NOTES REFER TO ALARM SYSTEM BUT SHEET CS
 INCLUDES A NOTE WHICH STATES THAT THIS TENANT DOES NOT
 HAVE A FIRE ALARM SYSTEM.
  
 6. THE CFM STATED ON THE FLOOR PLAN DO NOT APPEAR TO BE
 CONSISTENT WITH THE ASHRAE SCHEDULE ON M2. PLEASE CHECK
 AND REVISE AS NECESSARY.
  
 7. OUTSIDE AIR DUCT SHOWN ON PLAN NOTE 3 REQUIRES A
 DAMPER, FBC 13.409.AB.3.3.
  
 8. PROVIDE A STRUCTURAL INSTALLATION DETAIL FOR ROOFTOP
 EQUIPMENT, FBC M 301.12.
  
 HAROLD MOSER, MECHANICAL PLANS EXAMINER
 561-805-6732
  
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2011-07-12 Cont ID  
Sent By lwagner Date 2011-07-12 Time 10:47 Rev Time 0.00
Received By lwagner Date 2011-07-12 Time 10:31 Sent To  
Notes
2011-07-12 10:36:13SEPARATE MED GAS APPLICATION WITH VALUE, AND PERMIT
 REQUIRED
  
 ****NOTE****
 SHEET A2 #11 SHOWS CONCRETE ON TOP OF DRAINAGE PIPE.
 ISOLATE PIPEING FROM CONCRETE OR SLEEVE.