Plan Review Details - Permit 11050258
Plan Review Stops For Permit 11050258 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2011-08-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2011-08-30 |
Time |
13:22 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2011-08-30 |
Time |
13:22 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2011-06-02 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2011-06-02 |
Time |
13:16 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2011-06-01 |
Time |
11:21 |
Sent To |
|
|
Notes |
2011-06-02 13:36:08 | ****CORRECTIONS**** | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | FBC FLORIDA BUILDING CODE 2007 | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | 1. REVISE PLAN TO SHOW DISTANCE FROM GRADE TO BOTTOM OF | | AWNING, FBC3202. | | | | 2. PLEASE PROVIDE CLARIFICATION, IT IS NOT CLEAR HOW | | THE RAISED PARAPET WILL RESIST WIND LOADS FBC1609. IT | | APPEARS THAT THIS ACTS AS A VERTICAL CANTALEVER, BUT NO | | SUPPORTS TO PROVIDE STRUCTURAL CONTINUITY TO THE | | EXISTING STRUCTURE PROVIDED. PLEASE PROVIDE INFORMATION | | (CALCULATIONS, RATIONALE, ETC.) TO DEMONSTRATE THAT THE | | FASTENERS PROPOSED WILL BE ADEQUATE TO PREVENT THE | | RAISED PARAPET FROM FOLDING WHEN SUBJECTED TO WIND | | LOADS (BOTH DIRECTIONS). PLEASE CONTACT ME IF THE | | COMMENT DOES NOT CLEARLY EXPRESS CONCERNS. | | | | 3. INFORMATIONAL ONLY, AWNING ENGINEERING TO BE | | PROVIDED AT INSPECTION. | | | | 4. INFORMATIONAL ONLY, PLAN SHOWS PROPOSED ELECTRIC BUT | | NO ELECTRIC PLAN PROVIDED. ELECTRIC PLANS WILL BE | | REQUIRED WITH ELECTRIC PERMIT APPLICATION. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2011-09-01 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2011-09-01 |
Time |
15:26 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2011-09-01 |
Time |
15:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2011-09-01 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2011-09-01 |
Time |
15:27 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2011-08-18 |
Time |
17:44 |
Sent To |
|
|
Notes |
2011-08-18 17:44:29 | TO ZONING | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2011-06-02 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2011-06-02 |
Time |
13:36 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2011-05-09 |
Time |
16:12 |
Sent To |
|
|
Notes |
2011-05-09 16:12:54 | TO ZONING | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2011-08-22 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2011-08-22 |
Time |
10:06 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2011-08-19 |
Time |
13:29 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2011-05-25 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2011-05-25 |
Time |
16:36 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2011-05-12 |
Time |
15:23 |
Sent To |
B |
|
Notes |
2011-05-25 16:36:52 | ZONING PLAN REVIEW | | ___________________________________________ | | | | DATE OF REVIEW: 05.25.2011 | | PERMIT NO.: 11050258 | | ADDRESS: 607 25TH STREET | | CONTRACTOR/CONTACT: EZRA SAFFOLD | | TELEPHONE NO.: 561.848.1110 | | SCOPE OF REVIEW: DEMOLITION OF EXISTING MANSARD, | | NON-STRUCTURAL REPAIRS, AND INSTALL PARAPET SECTION AND | | PLANTERS. | | ___________________________________________ | | | | REVIEW STATUS: FAILED | | ___________________________________________ | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | REVIEW COMMENTS: | | | | 1. PURSUANT TO SECTION 94-213(D)(14) OF THE CITY?S | | ZONING AND LAND DEVELOPMENT REGULATIONS, AWNINGS SHALL | | PROJECT A MINIMUM OF FOUR (4) FEET FROM THE BUILDING | | FACE, AND SHALL HAVE A MINIMUM CLEARANCE OF NINE (9) | | FEET FROM THE SIDEWALK. | | ___________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | ___________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN ROACH, SENIOR PLANNER | | CITY OF WEST PALM BEACH | | PLANNING AND ZONING DEPARTMENT | | 401 CLEMATIS STREET - P.O. BOX 3366 | | WEST PALM BEACH, FLORIDA 33402 | | | | PHONE: 561.822.1435 | | FAX: 561.822.1460 | | | | EMAIL: [email protected] | | | | WWW.CITYOFWPB.COM | | |
|
|
|