Plan Review Details - Permit 11040532
Plan Review Stops For Permit 11040532
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2011-04-21 Cont ID  
Sent By jwitmer Date 2011-04-21 Time 12:32 Rev Time 0.55
Received By jwitmer Date 2011-04-21 Time 12:32 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2011-05-03 Cont ID  
Sent By rlecky Date 2011-05-03 Time 14:46 Rev Time 0.00
Received By rlecky Date 2011-05-03 Time 14:46 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2011-04-25 Cont ID  
Sent By rlecky Date 2011-04-25 Time 09:11 Rev Time 0.00
Received By rlecky Date 2011-04-25 Time 08:10 Sent To  
Notes
2011-04-25 09:11:07 
 ELECTRICAL PLAN INSUFFICIENTLY DETAILED TO APPROVE.
 PLEASE PROVIDE THE FOLLOWING.
  
 SHOW SIZE OF THE NEW ELECTRICAL PANEL. PROVIDE A PANEL
 SCHEDULE SHOWING NEW AND EXISTING LOADS. NEC 215.5
 PROVIDE GFCI PROTECTED OUTLETS IN THE BATHROOMS. NEC
 210.52
 ALL GENERAL PURPOSE OUTLETS INCLUDING THOSE IN THE
 BEDROOMS AND SMOKE ALARMS MUST BE AFCI PROTECTED. NEC
 210.12
 SHOW KITCHEN CIRCUITS WITH GFCI PROTECTION. COUNTER TOP
 RIGHT OF STOVE REQUIRES A RECEPTACLE. NEC 210.8, 210.52
 INTERCONNECT THE SD?S. FBC R313
 NEW RECEPTACLES MUST BE TAMPER RESISTANT. NEC 406.11
 A GFCI PROTECTED RECEPTACLE IS REQUIRED ON THE BALCONY.
 NEC 210.52
  
  
 ROBERT LECKY
 COMMERCIAL COMBINATION PLANS EXAMINER
 [email protected]
 561-805-6718
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2011-04-26 Cont ID  
Sent By wjolin Date 2011-04-26 Time 15:06 Rev Time 0.00
Received By wjolin Date 2011-04-26 Time 15:06 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-05-03 Cont ID  
Sent By rlecky Date 2011-05-03 Time 14:46 Rev Time 0.00
Received By rlecky Date 2011-05-02 Time 09:27 Sent To  
Notes
2011-05-02 09:27:41SENT TO LECKY'S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-04-26 Cont ID  
Sent By wjolin Date 2011-04-26 Time 15:06 Rev Time 0.00
Received By wjolin Date 2011-04-20 Time 13:32 Sent To  
Notes
2011-04-20 13:37:10******************EXPEDITED******************
 B--2
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2011-04-21 Cont ID  
Sent By lwagner Date 2011-04-21 Time 13:11 Rev Time 0.00
Received By lwagner Date 2011-04-21 Time 13:11 Sent To  
Notes
2011-04-21 13:12:07PLUMBING PERMIT REQUIRED

Review Stop Z ZONING
Rev No 1 Status N Date 2011-04-22 Cont ID  
Sent By eschneid Date 2011-04-22 Time 08:36 Rev Time 0.25
Received By eschneid Date 2011-04-22 Time 08:36 Sent To  
Notes
2011-04-22 08:37:25RESIDENTIAL CONDO INTERIOR REMODEL.