Plan Review Details - Permit 11030536
Plan Review Stops For Permit 11030536 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2011-03-31 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2011-03-31 |
Time |
14:01 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2011-03-31 |
Time |
13:13 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2011-03-21 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2011-03-21 |
Time |
15:27 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2011-03-21 |
Time |
15:20 |
Sent To |
PC |
|
Notes |
2011-03-21 15:55:40 | RESIDENTIAL (R3) SHUTTERS, BUILDING REVIEW CHECKLIST. | | 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. | | | | 1- WIND LOAD CALCULATIONS NEED TO HAVE ENGINEER'S | | ORIGINAL SEAL AND SIGNATURE AS REQUIRED BY CHAPTER 471 | | FLORIDA STATUTE. AND, BY NOTE #2 ON WIND LOAD SCHEDULE | | SUBMITTED. | | | | 2- REVISE SHUTTERS INSTALLATION SCHEDULE: | | A) SHUTTERS SPAN IS INCORRECT. SHUTTER SPAN FOR THE | | ACCORDION SHUTTERS IS TAKEN IN THE VERTICAL DIMENSION. | | SEE SHEET 5 OF 28 OF SHUTTERS DRAWINGS SUBMITTED AND | | REVISE AS REQUIRED. ***NOTE: TAKE INTO CONSIDERATION | | THE MINIMUM EDGE DISTANCE (3") WHEN CALCULATING THE | | SHUTTERS SPAN. | | | | B) PROPOSED SHUTTER SILL INSTALLATION (D) FOR OPENINGS | | 2 AND 3 IS NOT ALLOWED. SEE SHEET 13 OF 28 OF SHUTTERS | | DRAWINGS SUBMITTED. ACCORDING TO THE SHUTTER SPAN AND | | TYPE OF ANCHOR SELECTED (TAPCON) THIS INSTALLATION IS | | NOT ALLOWED. REVISE AS REQUIRED. | | | | C) REVISE ANCHOR SPACING FOR OPENING #1. TOP AND | | BOTTOM. ACCORDING TO THE CALCULATED DESIGN PRESSURES | | NEED TO USE 9" SPACING NOT 10". SEE SHEET 13 OF 28. | | | | D) REVISE ANCHOR SPACING FOR OPENING #2 ON HEADER SIDE. | | ACCORDING TO THE SHUTTER SPAN TAPCON NEED TO BE SPACED | | AT 7" NOT 10". SEE SHEET 13 OF 28. | | | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561)805-6712 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2011-03-31 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2011-03-31 |
Time |
14:00 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2011-03-30 |
Time |
15:49 |
Sent To |
|
|
Notes |
2011-03-30 16:05:49 | INCOMING SENT TO JULIO GOMEZ DESK. JW |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2011-03-21 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2011-03-21 |
Time |
15:20 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2011-03-21 |
Time |
15:20 |
Sent To |
|
|
Notes |
|
|
|