Plan Review Stops For Permit 11020273 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2011-04-29 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2011-04-29 |
Time |
13:52 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2011-04-29 |
Time |
13:52 |
Sent To |
|
|
Notes |
2011-04-29 13:53:44 | PROCESS PLANS WITH CORRECTED SURVEYS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2011-04-11 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2011-04-11 |
Time |
11:22 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2011-04-11 |
Time |
11:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2011-03-01 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2011-03-01 |
Time |
15:44 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2011-03-01 |
Time |
10:45 |
Sent To |
|
|
Notes |
2011-03-01 16:58:44 | 2007 FBC W/2009 REVISIONS | | | | DENIED BY BUILDING | | | | 1) SUBMIT TWO COPIES OF A SOIL TEST AS REQUIRED BY FBC | | R401.4 FROM A FLORIDA LICENSED GEO-TECHNICAL ENGINEER. | | | | 2) PROVIDE TWO COPIES OF A SURFACE WATER DRAINAGE PLAN | | TO SHOW COMPLIANCE WITH FBC R401.3. | | | | 3) SHOW COMPLIANCE WITH FBC R309.2 FOR GARAGE | | SEPARATION FROM THE RESIDENCE AND HABITABLE ROOMS | | ABOVE. | | | | 4) SHOW COMPLIANCE WITH FBC R502.1.2 FOR DRAFT-STOPPING | | FLOOR/CEILING ASSEMBLIES INTO AREAS OF CONCEALED SPACES | | NOT EXCEEDING 1000 SQFT. | | | | 5) SPECIFY THE TRUSS TO WALL CONNECTORS FOR THE UPPER | | AND LOWER ROOFS. | | | | 6) THE WALL SECTION ON SHEET 3 SPECIFIES A SIMPSON H-14 | | ANCHOR WHICH IS A TRUSS TO WOOD CONNECTOR. THE EXTERIOR | | WALLS ARE MASONRY AT THE FIRST AND SECOND FLOORS. | | PLEASE CORRECT. | | | | 7) PROVIDE AN ANCHOR/STRAPPING DETAIL FOR THE WOOD | | FRAMED CHIMNEY. | | | | 8) THE ENERGY CALCULATIONS AND THE ELECTRICAL PANEL | | SCHEDULE APPEAR TO INDICATE TWO TANKLESS ELECTRIC WATER | | HEATERS. THE ARCHITECTURAL PLANS DO NOT SPECIFY | | TANKLESS WATER HEATERS. PLEASE CLARIFY. | | | | 9) SPECIFY THE COMPONENT AND CLADDING PRESSURES FOR THE | | WINDOWS AND DOORS ON THE PLANS. THE WORSE CASE IS THE | | 30" OCTAGON WINDOWS LOCATED IN WALL ZONE 5 WITH | | TRIBUTARY AREAS OF LESS THAN 10 SQUARE FEET WITH 140 | | MPH WIND-SPEED IN EXPOSURE C WITH A MEAN ROOF HEIGHT OF | | 25 FEET. | | | | 10) SUBMIT TWO COPIES OF THE MANUFACTURER'S | | SPECIFICATIONS AND LISTINGS FOR THE GAS FIREPLACE AND | | FLUE. | | | | 11) FBC 106.3* CITY AMENDMENTS PRODUCT APPROVALS. THOSE | | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | 12) SUBMIT TWO COPIES OF THE PRODUCT APPROVALS FOR THE | | OVERHEAD GARAGE DOOR THAT WILL BE INSTALLED. | | | | 13) SPECIFY THE METHOD OF ATTACHMENT THAT WILL BE USED | | TO INSTALL THE ROOF TILE AND PROVIDE ADEQUATE | | RESISTANCE TO OVERTURNING MOMENT. IF ADHESIVE OR FOAM | | IS USED, SUBMIT THE APPROPRIATE PRODUCT APPROVALS. | | | | 14) SUBMIT PRODUCT APPROVALS FOR THE OUT-SWING ENTRY | | DOOR WITH A SIDELITE AS SHOWN ON THE PLANS. | | | | 15) SUBMIT PRODUCT APPROVALS FOR THE OUT-SWING GARAGE | | DOOR. | | | | 16) PRODUCT APPROVALS WERE SUBMITTED FOR A HORIZONTAL | | SLIDING WINDOW. THERE ARE NO WINDOWS OF THIS TYPE ARE | | SHOWN ON THE PLANS. PLEASE CLARIFY. | | | | 17) SUBMIT AN INSTALLATION SCHEDULE FOR THE STORM | | PANELS THAT WILL BE INSTALLED ON THE NON-IMPACT RATED | | DOOR. SPECIFY THE MOUNT TYPE, THE SPAN, THE GLASS | | SEPARATION, THE ANCHOR TYPE, ANCHOR SPACING, EDGE | | DISTANCE AND WALL SUBSTRATE. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2011-04-01 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2011-04-01 |
Time |
11:37 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2011-04-01 |
Time |
11:22 |
Sent To |
|
|
Notes |
2011-04-01 11:34:36 | NOTE: THE DESIGNER AND BUILDER OF RECORD CONFIREMED IN | | WRITING THE FAULT CURRENT AVAILABLE FROM FPL WAS LESS | | THAN THE 10,000 AIC RATING OF THE SERVICE EQUIPMENT. | | THEY ALSO CONFIRMED THAT EITHER CABLE OR CONDUIT MAY BE | | USED AS REQUIRED BY THE NEC. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2011-03-01 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2011-02-25 |
Time |
08:32 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2011-02-25 |
Time |
08:21 |
Sent To |
|
|
Notes |
2011-02-25 09:55:02 | PROVIDE ONE 20 AMP LAUNDRY CIRCUIT. NEC 210.11 (C) (2) | | PROVIDE A MINIMUM OF TWO 20 AMP KITCHEN CIRCUITS. NEC | | 210.11 (C)(1) | | PROVIDE A 20 AMP BRANCH CIRCUIT TO THE BATHROOMS. NEC | | 210.11 (C)(3) | | PROVIDE A KITCHEN RECEPTACLE AT THE PENINSULAR COUNTER | | TOP. NEC 210.50(C)(3) | | PROVIDE AN INTER SYSTEM BONDING STRIP AT ELECTRIC | | SERVICE. NEC 250.94 | | VERIFY THE AVAILABLE FAULT CURRENT IS LESS THAN 10,000 | | AIC RATED EQUIPMENT. NEC 110.9 | | | | IS THE SELECTED WIRING METHOD TO BE CONDUIT AND CABLE | | OR BOTH? | | PLEASE UPDATE THE PANEL SCHEDULE AND LOAD CALCULATION | | TO REFLECT ALL CHANGES. | | | | ROBERT LECKY, ELECTRICAL PLAN REVIEW, 561-805-6718 | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
P |
Date |
2011-04-21 |
|
|
Cont ID |
|
Sent By |
mgonzale |
Date |
2011-04-21 |
Time |
15:27 |
Rev Time |
1.00 |
Received By |
mgonzale |
Date |
2011-04-21 |
Time |
15:26 |
Sent To |
|
|
Notes |
2011-04-21 15:32:00 | PASSED WITH PROVISOS | | | | #1 DRIVEWAY PAVERS MUST SET ON SAND TO COMPLY WITH | | PERVIOUS AND IMPERVIOUS AREA CALC. | | | | #2 DRIVEWAY APRON WAS NOT SHOWN NOR IT IS INCLUDED IN | | THIS PERMIT. (A SEPARATE DRIVEWAY PERMIT MUST BE OBTAIN | | IF APRON IS MODIFIED OR MADE NEW.) | | | | #3 IF NEW DRIVEWAY APRON IS LATER ADDED AND IT'S | | CONSTRUCTED OF PAVERS THEN A "DRIVEWAY AGREEMENT" WILL | | NEED TO BE RECORDED AGAIN PROPERTY. | | HTTP://WWW.CITYOFWPB.COM/ENGINEERING/ENG_FORMS.PHP | | | | ANY QUESTIONS, PLEASE FEEL FREE TO CALL ME DIRECTLY. | | THANK YOU! | | | | MANUEL JULIAN GONZALEZ | | CSD ENGINEERING REVIEW | | 401 CLEMATIS STREET, 4TH FLOOR | | WEST PALM BEACH, FL 33401 | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | MAIN PHONE: (561) 822-1200 | | DIRECT: (561) 494-1085 | | FAX: (561) 494-1116 | | MOBILE: (561) 644-7301 | | EMAIL: [email protected] | | WWW.WPB.ORG/ENGINEERING | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2011-03-09 |
|
|
Cont ID |
|
Sent By |
|
Date |
2011-03-09 |
Time |
|
Rev Time |
0.00 |
Received By |
mgonzale |
Date |
2011-03-09 |
Time |
11:26 |
Sent To |
|
|
Notes |
2011-03-09 11:48:29 | #1 DIMENSION DRIVEWAYS, LOCATED HORIZONTALLY AND | | VERTICALLY. CALL OUT SETBACK | | | | #2 SHOW PROPOSED CONCRETE APRONS, CITY STANDARD DETAIL | | IS REQUIRED. | | SEE LINKS BELOW: HTTP://WWW.CITYOFWPB.COM/ENGINEERING/P | | DF/STANDARDS/GC?6.PDF | | HTTP://WWW.CITYOFWPB.COM/ENGINEERING/ENG_STANDARDS.HTM | | | | #3 IF USING PAVERS YOU MUST NEED TO EXECUTE A DRIVEWAY | | AGREEMENT. | | CONTACT: | | BRIAN R MOREE | | ENGINEERING SERVICES DEPARTMENT | | 401 CLEMATIS STREET | | WEST PALM BEACH, FL 33401 | | PHONE: 494?1040 EXT: 1098 | | FAX: 494?1118 | | E?MAIL: [email protected] | | | | #4 FOR CITY STANDARD CITY DRIVEWAY USING PAVERS | | CONTACT: JANICE J TARBILL TO OBTAIN DETAIL. | | COMPUTER AIDED DRAFTING TECHNICIAN LEADER | | ENGINEERING SERVICES DEPT | | ENGINEERING SERVICES DEPARTMENT | | 401 CLEMATIS STREET | | WEST PALM BEACH, FL 33401 | | PHONE: 494?1040 EXT: 1079 | | FAX: 494?1117 | | E?MAIL: [email protected] | | | | #5 CALCULATION FOR NEW DRIVEWAY IN CONFORMANCE WITH | | MUNICIPAL CODE REQUIRES THAT | | 75% OF YOUR FRONT YARD BE LANDSCAPE AREA (GREEN AREA) | | THE REMAINDER S.F. MAY BE UTILIZE FOR DRIVEWAY. IF | | USING PAVERS ON SAND BASE EXTRA S.F. MAY BE GRANTED. | | FOR QUESTIONS ON THE SUBJECT MATTER CONTACT: | | CITY OF WPB PLANNING DEPT. | | 401 CLEMATIS STREET, 2ND FLOOR | | W.P.B., FL 33401 | | MAILING ADDRESS: | | P.O. BOX 3366 | | W.P.B., FL 33402 | | PHONE: 561.822.1435 | | ****************************************** | | MANUEL JULIAN GONZALEZ | | CSD ENGINEERING REVIEW | | 401 CLEMATIS STREET, 4TH FLOOR | | WEST PALM BEACH, FL 33401 | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | MAIN PHONE: (561) 822?1200 | | DIRECT: (561) 494?1085 | | FAX: (561) 494?1116 | | MOBILE: (561) 644?7301 | | EMAIL: [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2011-04-22 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2011-04-22 |
Time |
14:56 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2011-03-31 |
Time |
14:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2011-03-31 |
|
|
Cont ID |
|
Sent By |
rlecky |
Date |
2011-03-15 |
Time |
13:59 |
Rev Time |
0.00 |
Received By |
rlecky |
Date |
2011-02-11 |
Time |
12:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2011-05-05 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2011-05-05 |
Time |
14:29 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2011-05-05 |
Time |
14:28 |
Sent To |
|
|
Notes |
2011-05-05 14:30:29 | MU-2011-007976-0000 |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2011-04-22 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2011-04-22 |
Time |
16:00 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2011-04-22 |
Time |
16:00 |
Sent To |
|
|
Notes |
2011-03-01 10:45:06 | NEEDS IMPACT FEE REVIEW |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2011-04-11 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2011-04-11 |
Time |
11:21 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2011-04-11 |
Time |
11:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2011-03-01 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2011-03-01 |
Time |
08:09 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2011-03-01 |
Time |
08:08 |
Sent To |
|
|
Notes |
2011-03-01 10:43:20 | 2007 FBC W/2009 REVISIONS | | | | DENIED BY MECHANICAL | | | | 1) SUBMIT TWO COPIES OF THE EQUIPMENT SIZING | | CALCULATIONS REQUIRED BY FBCR M1401.3. | | | | 2) THE PRINTED NAME, LICENSE NUMBER AND SIGNATURE OF | | THE PERSON RESPONSIBLE FOR THE MECHANICAL DESIGN IS | | REQUIRED TO BE ON THE MECHANICAL DRAWINGS. FS 471 & 481 | | | | 3) SPECIFY THE SIZES OF THE DUCTS THAT SUPPLY THE | | KITCHEN AND THE POWDER ROOMS ON THE FIRST FLOOR. | | | | 4) THE ENERGY COMPLIANCE FORM INDICATES THAT A CREDIT | | WAS TAKEN FOR CEILING FANS. C4.2.1.1 OF THE REVISED | | ENERGY CODE REQUIRES CEILING FANS IN ALL PRIMARY LIVING | | AREAS IN ADDITION TO EACH BEDROOM. THE ELECTRICAL PLAN | | DOES NOT SHOW A CEILING FAN IN THE LIVING ROOM, | | THEREFORE THE CREDIT CAN NOT BE TAKEN. PLEASE CORRECT. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2011-03-01 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2011-03-01 |
Time |
08:03 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2011-03-01 |
Time |
07:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2011-04-20 |
|
|
Cont ID |
|
Sent By |
astelly |
Date |
2011-04-20 |
Time |
09:11 |
Rev Time |
0.00 |
Received By |
astelly |
Date |
2011-04-20 |
Time |
09:11 |
Sent To |
|
|
Notes |
2011-04-20 09:14:11 | AMY STELLY | | PLANNING AND ZONING | | 561-822-1442 | | | | PASSED W/PROVISO | | A SEPARATE LANDSCAPE PERMIT IS REQUIRED. SINGLE -FAMILY | | RESIDENCES WITH A SINGLE ACCESS POINT MAY NOT HAVE | | DRIVEWAYS THAT EXCEED 20 FEET IN WIDTH. THE FULLY | | DIMENSIONED DRIVEWAY MUST BE SHOWN ON THE LANDSCAPE | | PLAN. | | | | LOTS 9 AND 10 MUST RECEIVE A NEW ADDRESS. PLEASE | | CONTACT THE MIS DEPARTMENT TO ADDRESS THIS ITEM. | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2011-04-15 |
|
|
Cont ID |
|
Sent By |
astelly |
Date |
2011-04-15 |
Time |
15:37 |
Rev Time |
0.00 |
Received By |
astelly |
Date |
2011-04-15 |
Time |
15:37 |
Sent To |
|
|
Notes |
2011-04-15 16:25:33 | AMY STELLY | | PLANNING AND ZONING | | 561-822-1442 | | | | A SEPARATE DRIVEWAY PERMIT IS REQUIRED. SINGLE -FAMILY | | RESIDENCES WITH A SINGLE ACCESS POINT MAY NOT HAVE | | DRIVEWAYS THAT EXCEED 20 FEET IN WIDTH. THE FULLY | | DIMENSIONED DRIVEWAY MUST BE SHOWN ON THE LANDSCAPE | | PLAN. | | | | LOTS 9 AND 10 MUST RECEIVE A NEW ADDRESS. PLEASE | | CONTACT THE MIS DEPARTMENT TO ADDRESS THIS ITEM. | | | | THE MECHANICAL EQUIPMENT IS NOT SHOWN ON THE SITE PLAN. | | IN ACCORDANCE WITH SEC. 94-305(B)(4), MECHANICAL | | EQUIPMENT MAY NOT PROJECT MORE THAN FOUR FEET INTO A | | SETBACK |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2011-03-15 |
|
|
Cont ID |
|
Sent By |
astelly |
Date |
2011-03-15 |
Time |
11:54 |
Rev Time |
0.00 |
Received By |
astelly |
Date |
2011-03-15 |
Time |
11:54 |
Sent To |
|
|
Notes |
2011-03-15 13:11:52 | AMY STELLY | | PLANNING AND ZONING | | 561-822-1442 | | | | AN UPDATED SURVEY SHOWING THAT THE HOUSE AND SHED HAVE | | BEEN DEMOLISHED IS REQUIRED. | | | | PLEASE PROVIDE A COPY OF THE UNITY OF TITLE FOR THE | | PROPERTY PER THE CONDITIONS OF THE SEPTEMBER 16, 2009 | | APPROVAL LETTER FOR THE SUBDIVISION OF THE PROPERTY. | | | | THE VALUE OF THE IMPROVEMENT EXCEEDS THE VALUE OF THE | | LAND. AS A RESULT, LANDSCAPE PLAN IS REQUIRED FOR | | APPROVAL IN ACCORDANCE WITH SEC. 94-441(C)(2) OF THE | | ZONING CODE. | | | | IN ADDITION, SEPARATE PERMITS WILL BE REQUIRED FOR THE | | DRIVEWAY AND THE POOL. | | | | |
|
|