Plan Review Details - Permit 11020273
Plan Review Stops For Permit 11020273
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2011-04-29 Cont ID  
Sent By rmcdouga Date 2011-04-29 Time 13:52 Rev Time 0.00
Received By rmcdouga Date 2011-04-29 Time 13:52 Sent To  
Notes
2011-04-29 13:53:44PROCESS PLANS WITH CORRECTED SURVEYS

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2011-04-11 Cont ID  
Sent By rmcdouga Date 2011-04-11 Time 11:22 Rev Time 0.00
Received By rmcdouga Date 2011-04-11 Time 11:22 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2011-03-01 Cont ID  
Sent By rmcdouga Date 2011-03-01 Time 15:44 Rev Time 0.00
Received By rmcdouga Date 2011-03-01 Time 10:45 Sent To  
Notes
2011-03-01 16:58:442007 FBC W/2009 REVISIONS
  
 DENIED BY BUILDING
  
 1) SUBMIT TWO COPIES OF A SOIL TEST AS REQUIRED BY FBC
 R401.4 FROM A FLORIDA LICENSED GEO-TECHNICAL ENGINEER.
  
 2) PROVIDE TWO COPIES OF A SURFACE WATER DRAINAGE PLAN
 TO SHOW COMPLIANCE WITH FBC R401.3.
  
 3) SHOW COMPLIANCE WITH FBC R309.2 FOR GARAGE
 SEPARATION FROM THE RESIDENCE AND HABITABLE ROOMS
 ABOVE.
  
 4) SHOW COMPLIANCE WITH FBC R502.1.2 FOR DRAFT-STOPPING
 FLOOR/CEILING ASSEMBLIES INTO AREAS OF CONCEALED SPACES
 NOT EXCEEDING 1000 SQFT.
  
 5) SPECIFY THE TRUSS TO WALL CONNECTORS FOR THE UPPER
 AND LOWER ROOFS.
  
 6) THE WALL SECTION ON SHEET 3 SPECIFIES A SIMPSON H-14
 ANCHOR WHICH IS A TRUSS TO WOOD CONNECTOR. THE EXTERIOR
 WALLS ARE MASONRY AT THE FIRST AND SECOND FLOORS.
 PLEASE CORRECT.
  
 7) PROVIDE AN ANCHOR/STRAPPING DETAIL FOR THE WOOD
 FRAMED CHIMNEY.
  
 8) THE ENERGY CALCULATIONS AND THE ELECTRICAL PANEL
 SCHEDULE APPEAR TO INDICATE TWO TANKLESS ELECTRIC WATER
 HEATERS. THE ARCHITECTURAL PLANS DO NOT SPECIFY
 TANKLESS WATER HEATERS. PLEASE CLARIFY.
  
 9) SPECIFY THE COMPONENT AND CLADDING PRESSURES FOR THE
 WINDOWS AND DOORS ON THE PLANS. THE WORSE CASE IS THE
 30" OCTAGON WINDOWS LOCATED IN WALL ZONE 5 WITH
 TRIBUTARY AREAS OF LESS THAN 10 SQUARE FEET WITH 140
 MPH WIND-SPEED IN EXPOSURE C WITH A MEAN ROOF HEIGHT OF
 25 FEET.
  
 10) SUBMIT TWO COPIES OF THE MANUFACTURER'S
 SPECIFICATIONS AND LISTINGS FOR THE GAS FIREPLACE AND
 FLUE.
  
 11) FBC 106.3* CITY AMENDMENTS PRODUCT APPROVALS. THOSE
 PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
  
 12) SUBMIT TWO COPIES OF THE PRODUCT APPROVALS FOR THE
 OVERHEAD GARAGE DOOR THAT WILL BE INSTALLED.
  
 13) SPECIFY THE METHOD OF ATTACHMENT THAT WILL BE USED
 TO INSTALL THE ROOF TILE AND PROVIDE ADEQUATE
 RESISTANCE TO OVERTURNING MOMENT. IF ADHESIVE OR FOAM
 IS USED, SUBMIT THE APPROPRIATE PRODUCT APPROVALS.
  
 14) SUBMIT PRODUCT APPROVALS FOR THE OUT-SWING ENTRY
 DOOR WITH A SIDELITE AS SHOWN ON THE PLANS.
  
 15) SUBMIT PRODUCT APPROVALS FOR THE OUT-SWING GARAGE
 DOOR.
  
 16) PRODUCT APPROVALS WERE SUBMITTED FOR A HORIZONTAL
 SLIDING WINDOW. THERE ARE NO WINDOWS OF THIS TYPE ARE
 SHOWN ON THE PLANS. PLEASE CLARIFY.
  
 17) SUBMIT AN INSTALLATION SCHEDULE FOR THE STORM
 PANELS THAT WILL BE INSTALLED ON THE NON-IMPACT RATED
 DOOR. SPECIFY THE MOUNT TYPE, THE SPAN, THE GLASS
 SEPARATION, THE ANCHOR TYPE, ANCHOR SPACING, EDGE
 DISTANCE AND WALL SUBSTRATE.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2011-04-01 Cont ID  
Sent By rlecky Date 2011-04-01 Time 11:37 Rev Time 0.00
Received By rlecky Date 2011-04-01 Time 11:22 Sent To  
Notes
2011-04-01 11:34:36NOTE: THE DESIGNER AND BUILDER OF RECORD CONFIREMED IN
 WRITING THE FAULT CURRENT AVAILABLE FROM FPL WAS LESS
 THAN THE 10,000 AIC RATING OF THE SERVICE EQUIPMENT.
 THEY ALSO CONFIRMED THAT EITHER CABLE OR CONDUIT MAY BE
 USED AS REQUIRED BY THE NEC.
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2011-03-01 Cont ID  
Sent By rlecky Date 2011-02-25 Time 08:32 Rev Time 0.00
Received By rlecky Date 2011-02-25 Time 08:21 Sent To  
Notes
2011-02-25 09:55:02PROVIDE ONE 20 AMP LAUNDRY CIRCUIT. NEC 210.11 (C) (2)
 PROVIDE A MINIMUM OF TWO 20 AMP KITCHEN CIRCUITS. NEC
 210.11 (C)(1)
 PROVIDE A 20 AMP BRANCH CIRCUIT TO THE BATHROOMS. NEC
 210.11 (C)(3)
 PROVIDE A KITCHEN RECEPTACLE AT THE PENINSULAR COUNTER
 TOP. NEC 210.50(C)(3)
 PROVIDE AN INTER SYSTEM BONDING STRIP AT ELECTRIC
 SERVICE. NEC 250.94
 VERIFY THE AVAILABLE FAULT CURRENT IS LESS THAN 10,000
 AIC RATED EQUIPMENT. NEC 110.9
  
 IS THE SELECTED WIRING METHOD TO BE CONDUIT AND CABLE
 OR BOTH?
 PLEASE UPDATE THE PANEL SCHEDULE AND LOAD CALCULATION
 TO REFLECT ALL CHANGES.
  
 ROBERT LECKY, ELECTRICAL PLAN REVIEW, 561-805-6718
  

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2011-04-21 Cont ID  
Sent By mgonzale Date 2011-04-21 Time 15:27 Rev Time 1.00
Received By mgonzale Date 2011-04-21 Time 15:26 Sent To  
Notes
2011-04-21 15:32:00PASSED WITH PROVISOS
  
 #1 DRIVEWAY PAVERS MUST SET ON SAND TO COMPLY WITH
 PERVIOUS AND IMPERVIOUS AREA CALC.
  
 #2 DRIVEWAY APRON WAS NOT SHOWN NOR IT IS INCLUDED IN
 THIS PERMIT. (A SEPARATE DRIVEWAY PERMIT MUST BE OBTAIN
 IF APRON IS MODIFIED OR MADE NEW.)
  
 #3 IF NEW DRIVEWAY APRON IS LATER ADDED AND IT'S
 CONSTRUCTED OF PAVERS THEN A "DRIVEWAY AGREEMENT" WILL
 NEED TO BE RECORDED AGAIN PROPERTY.
 HTTP://WWW.CITYOFWPB.COM/ENGINEERING/ENG_FORMS.PHP
  
 ANY QUESTIONS, PLEASE FEEL FREE TO CALL ME DIRECTLY.
 THANK YOU!
  
 MANUEL JULIAN GONZALEZ
 CSD ENGINEERING REVIEW
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 MOBILE: (561) 644-7301
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2011-03-09 Cont ID  
Sent By   Date 2011-03-09 Time   Rev Time 0.00
Received By mgonzale Date 2011-03-09 Time 11:26 Sent To  
Notes
2011-03-09 11:48:29#1 DIMENSION DRIVEWAYS, LOCATED HORIZONTALLY AND
 VERTICALLY. CALL OUT SETBACK
  
 #2 SHOW PROPOSED CONCRETE APRONS, CITY STANDARD DETAIL
 IS REQUIRED.
 SEE LINKS BELOW: HTTP://WWW.CITYOFWPB.COM/ENGINEERING/P
 DF/STANDARDS/GC?6.PDF
 HTTP://WWW.CITYOFWPB.COM/ENGINEERING/ENG_STANDARDS.HTM
  
 #3 IF USING PAVERS YOU MUST NEED TO EXECUTE A DRIVEWAY
 AGREEMENT.
 CONTACT:
 BRIAN R MOREE
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET
 WEST PALM BEACH, FL 33401
 PHONE: 494?1040 EXT: 1098
 FAX: 494?1118
 E?MAIL: [email protected]
  
 #4 FOR CITY STANDARD CITY DRIVEWAY USING PAVERS
 CONTACT: JANICE J TARBILL TO OBTAIN DETAIL.
 COMPUTER AIDED DRAFTING TECHNICIAN LEADER
 ENGINEERING SERVICES DEPT
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET
 WEST PALM BEACH, FL 33401
 PHONE: 494?1040 EXT: 1079
 FAX: 494?1117
 E?MAIL: [email protected]
  
 #5 CALCULATION FOR NEW DRIVEWAY IN CONFORMANCE WITH
 MUNICIPAL CODE REQUIRES THAT
 75% OF YOUR FRONT YARD BE LANDSCAPE AREA (GREEN AREA)
 THE REMAINDER S.F. MAY BE UTILIZE FOR DRIVEWAY. IF
 USING PAVERS ON SAND BASE EXTRA S.F. MAY BE GRANTED.
 FOR QUESTIONS ON THE SUBJECT MATTER CONTACT:
 CITY OF WPB PLANNING DEPT.
 401 CLEMATIS STREET, 2ND FLOOR
 W.P.B., FL 33401
 MAILING ADDRESS:
 P.O. BOX 3366
 W.P.B., FL 33402
 PHONE: 561.822.1435
 ******************************************
 MANUEL JULIAN GONZALEZ
 CSD ENGINEERING REVIEW
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822?1200
 DIRECT: (561) 494?1085
 FAX: (561) 494?1116
 MOBILE: (561) 644?7301
 EMAIL: [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2011-04-22 Cont ID  
Sent By rmcdouga Date 2011-04-22 Time 14:56 Rev Time 0.00
Received By rmcdouga Date 2011-03-31 Time 14:00 Sent To  
Notes
2011-03-31 14:03:54R6

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2011-03-31 Cont ID  
Sent By rlecky Date 2011-03-15 Time 13:59 Rev Time 0.00
Received By rlecky Date 2011-02-11 Time 12:39 Sent To  
Notes
2011-02-11 12:39:59R14
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2011-05-05 Cont ID  
Sent By rmcdouga Date 2011-05-05 Time 14:29 Rev Time 0.00
Received By rmcdouga Date 2011-05-05 Time 14:28 Sent To  
Notes
2011-05-05 14:30:29MU-2011-007976-0000

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2011-04-22 Cont ID  
Sent By rmcdouga Date 2011-04-22 Time 16:00 Rev Time 0.00
Received By rmcdouga Date 2011-04-22 Time 16:00 Sent To  
Notes
2011-03-01 10:45:06NEEDS IMPACT FEE REVIEW

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2011-04-11 Cont ID  
Sent By rmcdouga Date 2011-04-11 Time 11:21 Rev Time 0.00
Received By rmcdouga Date 2011-04-11 Time 11:21 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2011-03-01 Cont ID  
Sent By rmcdouga Date 2011-03-01 Time 08:09 Rev Time 0.00
Received By rmcdouga Date 2011-03-01 Time 08:08 Sent To  
Notes
2011-03-01 10:43:202007 FBC W/2009 REVISIONS
  
 DENIED BY MECHANICAL
  
 1) SUBMIT TWO COPIES OF THE EQUIPMENT SIZING
 CALCULATIONS REQUIRED BY FBCR M1401.3.
  
 2) THE PRINTED NAME, LICENSE NUMBER AND SIGNATURE OF
 THE PERSON RESPONSIBLE FOR THE MECHANICAL DESIGN IS
 REQUIRED TO BE ON THE MECHANICAL DRAWINGS. FS 471 & 481
  
 3) SPECIFY THE SIZES OF THE DUCTS THAT SUPPLY THE
 KITCHEN AND THE POWDER ROOMS ON THE FIRST FLOOR.
  
 4) THE ENERGY COMPLIANCE FORM INDICATES THAT A CREDIT
 WAS TAKEN FOR CEILING FANS. C4.2.1.1 OF THE REVISED
 ENERGY CODE REQUIRES CEILING FANS IN ALL PRIMARY LIVING
 AREAS IN ADDITION TO EACH BEDROOM. THE ELECTRICAL PLAN
 DOES NOT SHOW A CEILING FAN IN THE LIVING ROOM,
 THEREFORE THE CREDIT CAN NOT BE TAKEN. PLEASE CORRECT.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]

Review Stop P PLUMBING
Rev No 1 Status P Date 2011-03-01 Cont ID  
Sent By rmcdouga Date 2011-03-01 Time 08:03 Rev Time 0.00
Received By rmcdouga Date 2011-03-01 Time 07:01 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2011-04-20 Cont ID  
Sent By astelly Date 2011-04-20 Time 09:11 Rev Time 0.00
Received By astelly Date 2011-04-20 Time 09:11 Sent To  
Notes
2011-04-20 09:14:11AMY STELLY
 PLANNING AND ZONING
 561-822-1442
  
 PASSED W/PROVISO
 A SEPARATE LANDSCAPE PERMIT IS REQUIRED. SINGLE -FAMILY
 RESIDENCES WITH A SINGLE ACCESS POINT MAY NOT HAVE
 DRIVEWAYS THAT EXCEED 20 FEET IN WIDTH. THE FULLY
 DIMENSIONED DRIVEWAY MUST BE SHOWN ON THE LANDSCAPE
 PLAN.
  
 LOTS 9 AND 10 MUST RECEIVE A NEW ADDRESS. PLEASE
 CONTACT THE MIS DEPARTMENT TO ADDRESS THIS ITEM.
  
  

Review Stop Z ZONING
Rev No 2 Status F Date 2011-04-15 Cont ID  
Sent By astelly Date 2011-04-15 Time 15:37 Rev Time 0.00
Received By astelly Date 2011-04-15 Time 15:37 Sent To  
Notes
2011-04-15 16:25:33AMY STELLY
 PLANNING AND ZONING
 561-822-1442
  
 A SEPARATE DRIVEWAY PERMIT IS REQUIRED. SINGLE -FAMILY
 RESIDENCES WITH A SINGLE ACCESS POINT MAY NOT HAVE
 DRIVEWAYS THAT EXCEED 20 FEET IN WIDTH. THE FULLY
 DIMENSIONED DRIVEWAY MUST BE SHOWN ON THE LANDSCAPE
 PLAN.
  
 LOTS 9 AND 10 MUST RECEIVE A NEW ADDRESS. PLEASE
 CONTACT THE MIS DEPARTMENT TO ADDRESS THIS ITEM.
  
 THE MECHANICAL EQUIPMENT IS NOT SHOWN ON THE SITE PLAN.
 IN ACCORDANCE WITH SEC. 94-305(B)(4), MECHANICAL
 EQUIPMENT MAY NOT PROJECT MORE THAN FOUR FEET INTO A
 SETBACK

Review Stop Z ZONING
Rev No 1 Status F Date 2011-03-15 Cont ID  
Sent By astelly Date 2011-03-15 Time 11:54 Rev Time 0.00
Received By astelly Date 2011-03-15 Time 11:54 Sent To  
Notes
2011-03-15 13:11:52AMY STELLY
 PLANNING AND ZONING
 561-822-1442
  
 AN UPDATED SURVEY SHOWING THAT THE HOUSE AND SHED HAVE
 BEEN DEMOLISHED IS REQUIRED.
  
 PLEASE PROVIDE A COPY OF THE UNITY OF TITLE FOR THE
 PROPERTY PER THE CONDITIONS OF THE SEPTEMBER 16, 2009
 APPROVAL LETTER FOR THE SUBDIVISION OF THE PROPERTY.
  
 THE VALUE OF THE IMPROVEMENT EXCEEDS THE VALUE OF THE
 LAND. AS A RESULT, LANDSCAPE PLAN IS REQUIRED FOR
 APPROVAL IN ACCORDANCE WITH SEC. 94-441(C)(2) OF THE
 ZONING CODE.
  
 IN ADDITION, SEPARATE PERMITS WILL BE REQUIRED FOR THE
 DRIVEWAY AND THE POOL.
  
  